D<br />

<strong>LED</strong> <strong>light</strong> <strong>engine</strong> / O<strong>LED</strong><br />

<strong>LED</strong> <strong>compact</strong><br />

Product description<br />

• Ideal for ceiling-mounted and wallmounted luminaires<br />

• Efficiency of the module up to 125 lm/W<br />

• High colour rendering index CRI > 80<br />

• Small colour tolerance MacAdam 4 4<br />

• Small luminous flux tolerances<br />

• Colour temperatures 3,000 and 4,000 K<br />

• Self-cooling (no additional heat sink required)<br />

• Push terminals for quick and simple wiring<br />

• Simple installation (e.g. screws)<br />

• Long life-time: 50,000 hours<br />

• 5-year guarantee<br />

Technical data<br />

Beam characteristic 120°<br />

Ambient temperature ta -30 ... +50 °C<br />

Typ. tp point 65 °C<br />

Risk group (EN 62471:2008) 0<br />

Type of protection<br />

IP00<br />

È<br />

Standards, page 2<br />

For colour temperatures and tolerances, page 5<br />

<strong>Umodule</strong> <strong>STARK</strong> CLE 160-2200 CLASSIC<br />

<strong>STARK</strong> CLE<br />

92<br />

33,25<br />

33,25<br />

92<br />

Ø4,5<br />

Ø11<br />

tp<br />

Ø164,5<br />

Ordering data<br />

Type<br />

Article number<br />

Colour Packaging, Weight<br />

temperature carton per pc.<br />

<strong>STARK</strong>-CLE-160-2200-830-CLA 89601846 3,000 K 50 pc(s). 0.074 kg<br />

<strong>STARK</strong>-CLE-160-2200-840-CLA 89601847 4,000 K 50 pc(s). 0.074 kg<br />

Specific technical data<br />

Type<br />

Photometric Typ. luminous Typ. luminous Typ. forward Typ. forward Typ. power Luminous Luminous Luminous Colour rendering Energy<br />

code flux at flux at current 123 voltage consumption 1 efficacy module efficacy module efficacy system index CRI classification<br />

tp 25 °C 1 tp 65 °C 1<br />

at tp 25 °C at tp 65 °C at tp 65 °C<br />

Operating mode at 350 mA<br />

<strong>STARK</strong>-CLE-160-2200-830-CLA 830/4xx 2,130 lm 2,050 lm 350 mA 51.4 V 18 W 118 lm/W 114 lm/W 97 lm/W > 80 A+<br />

<strong>STARK</strong>-CLE-160-2200-840-CLA 840/4xx 2,280 lm 2,190 lm 350 mA 51.4 V 18 W 127 lm/W 122 lm/W 104 lm/W > 80 A+<br />

1 Tolerance range for optical and electrical data: ±10 %.<br />

2 Max. permissible repetitive peak current: 480 mA.<br />

3 Max. permissible surge current: 0.54 A, duration max. 10 ms.<br />

4 Integrated measurement over the whole module.<br />

PHASED OUT<br />

79,25<br />

158,5<br />

Data sheet 07/14-<strong>LED</strong>150-2<br />

Subject to change without notice.<br />

www.tridonic.com 1


<strong>LED</strong> <strong>light</strong> <strong>engine</strong> / O<strong>LED</strong><br />

<strong>LED</strong> <strong>compact</strong><br />

Standards<br />

EN 62031<br />

EN 62471<br />

IEC 61000-4-2<br />

Photometric code<br />

Key for photometric code, e. g. 830 / 449<br />

1 st digit 2 nd + 3 rd digit 4 th digit 5 th digit 6 th digit<br />

Lumen maintanance after 25%<br />

Code CRI<br />

McAdams after of the life-time (max.6000h)<br />

Colour temperature in McAdams 25% of the Code Remaining lumen<br />

7 67 – 76 Kelvin x 100 initial life-time (max. 7 ≥ 70 %<br />

8 77 – 86 6,000h) 8 ≥ 80 %<br />

9 87 – ≥90 9 ≥ 90 %<br />

Thermal design and heat sink<br />

The rated life of u products depends to a large extent on the temperature. If<br />

the permissible temperature limits are exceeded, the life of the<br />

umodule <strong>STARK</strong> CLE will be greatly reduced or the umodule <strong>STARK</strong> CLE<br />

may be destroyed.<br />

tp point, ambient temperature and life-time<br />

The temperature at tp reference point is crucial for the <strong>light</strong> output and life-time<br />

of a u product.<br />

For umodule <strong>STARK</strong> CLE a tp temperature of 65 °C has to be complied in order<br />

to achieve an optimum between <strong>light</strong> output and life-time.<br />

Compliance with the maximum permissible reference temperature at the tp point<br />

must be checked under operating conditions in a thermally stable state. The<br />

maximum value must be determined under worst-case conditions for the relevant<br />

application.<br />

The tc and tp temperature of <strong>LED</strong> modules from <strong>Tridonic</strong> are measured at the same<br />

reference point.<br />

Mounting instruction<br />

None of the components of the umodule <strong>STARK</strong> CLE (substrate, <strong>LED</strong>,<br />

electronic components etc.) may be exposed to tensile or compressive<br />

stresses.<br />

Max. torque for fixing: 0.5 Nm.<br />

The <strong>LED</strong> modules are mounted with 4 screws per module.<br />

In order not to damage the modules only rounded head screws and an<br />

additional plastic flat washer should be used.<br />

PHASED OUT<br />

EOS/ESD safety guidelines<br />

The device / module contains components that are sensitive to electrostatic<br />

discharge and may only be installed in the factory and on site if<br />

appropriate EOS/ESD protection measures have been taken. No special<br />

measures need be taken for devices/modules with enclosed casings<br />

(contact with the pc board not possible), just normal installation practice.<br />

Please note the requirements set out in the document EOS / ESD<br />

guidelines (Guideline_EOS_ESD.pdf) at:<br />

http://www.tridonic.com/esd-protection<br />

Data sheet 07/14-<strong>LED</strong>150-2<br />

Subject to change without notice.<br />

www.tridonic.com 2


<strong>LED</strong> <strong>light</strong> <strong>engine</strong> / O<strong>LED</strong><br />

<strong>LED</strong> <strong>compact</strong><br />

Thermal behaviour<br />

storage temperature -30... +80 °C<br />

operating temperature ta -30 ... +50 °C<br />

tp (at typ. current) 65 °C<br />

tc max. (at typ. current) 75 °C<br />

max. humidity* 0 ... 70 %<br />

* not condensed<br />

Lumen maintenance<br />

tp temperature in °C forward current in mA luminous flux in % operating time in h<br />

65 350 70 > 45,000<br />

Electrical supply/choice of <strong>LED</strong> control gear<br />

umodule <strong>STARK</strong> CLE from <strong>Tridonic</strong> are not protected against overvoltages,<br />

overcurrents, overloads or short-circuit currents. Safe and reliable operation<br />

can only be guaranteed in conjunction with a <strong>LED</strong> control gear which complies with<br />

the relevant standards. The use of uconverter from <strong>Tridonic</strong> in combination<br />

with umodule <strong>STARK</strong> CLE guarantees the necessary protection for safe and<br />

reliable operation.<br />

Wiring<br />

umodule <strong>STARK</strong> LLE are basic isolated up to 190 V against ground<br />

and can be mounted directly on earthed metal parts of the luminaire.<br />

If the max. output voltage of the led control gear (also against earth) is<br />

above 190 V, an additional isolation between <strong>LED</strong> module and heat sink is<br />

required (for example by isolated thermal pads) or by a suitable luminaire<br />

construction.<br />

At voltages > 60 V an additional protection against direct touch (test<br />

finger) to the <strong>light</strong> emitting side of the module has to be guaranteed. This<br />

is typically achieved by means of a non removable <strong>light</strong> distributor over the<br />

module.<br />

Wiring type and cross section<br />

The wiring can be solid cable with a cross section of<br />

0.4 to 0.75 mm². For the push-wire connection you<br />

have to strip the insulation (6–7 mm).<br />

Loosen wire through twisting and pulling.<br />

wire preparation:<br />

0.4 – 0.75 mm²<br />

+ –<br />

6 – 7 mm<br />

Release of the wiring<br />

Press down the “push button” and remove the cable from front.<br />

Wiring example<br />

230 – 240 V AC<br />

50/60 Hz<br />

L<br />

N<br />

PE<br />

<strong>Umodule</strong><br />

<strong>STARK</strong> CLE 160<br />

+ <strong>LED</strong><br />

– <strong>LED</strong><br />

Uconverter<br />

LCI ... TEC C<br />

N<br />

L<br />

SEC<br />

PRI<br />

+<br />

–<br />

If a <strong>LED</strong> control gear other than <strong>Tridonic</strong> uconverter is used, it must provide the<br />

following protection:<br />

• Short-circuit protection<br />

• Overload protection<br />

• Overtemperature protection<br />

umodule <strong>STARK</strong> CLE must be supplied by a constant current <strong>LED</strong><br />

control gear.<br />

Operation with a constant voltage <strong>LED</strong> control gear will lead to an irreversible<br />

damage of the module.<br />

Wrong polarity can damage the umodule <strong>STARK</strong> CLE.<br />

PHASED OUT<br />

Data sheet 07/14-<strong>LED</strong>150-2<br />

Subject to change without notice.<br />

www.tridonic.com 3


<strong>LED</strong> <strong>light</strong> <strong>engine</strong> / O<strong>LED</strong><br />

<strong>LED</strong> <strong>compact</strong><br />

Relative luminous flux<br />

Forward current vs. forward voltage<br />

rel. luminous flux [%]<br />

Relative luminous flux vs. operating current<br />

rel. luminous flux [%]<br />

The diagrams based on statistic values.<br />

The real values can be different.<br />

Optical characteristics <strong>Umodule</strong> <strong>STARK</strong> CLE<br />

The optical design of the umodule <strong>STARK</strong> CLE product line ensures optimum<br />

homogenity for the <strong>light</strong> distribution.<br />

Light distribution<br />

relative intensity Iv/Iv, max<br />

110<br />

100<br />

90<br />

80<br />

70<br />

25 35 45 55 65 75 85<br />

tp [°C]<br />

1,4<br />

1,2<br />

1,0<br />

0,8<br />

0,6<br />

0,4<br />

0,2<br />

200<br />

100<br />

80<br />

60 -60°<br />

40<br />

-50°<br />

250 300 350 400 450 500<br />

Operating current [mA]<br />

-40°<br />

-30°<br />

-20°<br />

-10°<br />

0°<br />

20<br />

80°<br />

10°<br />

20°<br />

30°<br />

40°<br />

50°<br />

60°<br />

70°<br />

Forward current [mA]<br />

480<br />

440<br />

400<br />

360<br />

320<br />

280<br />

240<br />

200<br />

160<br />

120<br />

80<br />

40<br />

0<br />

40,8 42,5 44,2 45,9 47,6 49,3 51,0 52,7 54,4<br />

Forward voltage [V]<br />

The colour temperature is measured integral over the complete module.<br />

The single <strong>LED</strong> <strong>light</strong> points can have deviations in the colour coordinates<br />

within MacAdam tbd.<br />

To ensure an ideal mixture of colours and a homogenious <strong>light</strong> distribution<br />

a suitable optic (e. g. PMMA diffuser) and a sufficient spacing between<br />

module and optic (typ. 5 cm) should be used.<br />

PHASED OUT<br />

0<br />

-100<br />

-80<br />

-60<br />

-40<br />

-20 0 20 40<br />

60<br />

80 100<br />

90°<br />

3D-Data, photometric data and Design-in guide available on request or go to www.<br />

tridonic.com<br />

Data sheet 07/14-<strong>LED</strong>150-2<br />

Subject to change without notice.<br />

www.tridonic.com 4


<strong>LED</strong> <strong>light</strong> <strong>engine</strong> / O<strong>LED</strong><br />

<strong>LED</strong> <strong>compact</strong><br />

Coordinates and tolerances according to CIE 1931<br />

The specified colour coordinates are measured integral by a current impulse with typical values of module and a duration of 200 ms.<br />

The ambient temperature of the measurement is ta = 25 °C.<br />

The measurement tolerance of the colour coordinates are ± 0.01.<br />

3,000 K<br />

x0<br />

y0<br />

Centre 0.4344 0.4032<br />

0,4250<br />

0,4200<br />

0,4150<br />

0,4100<br />

0,4050<br />

0,4000<br />

0,3950<br />

0,3900<br />

0,3850<br />

4,000 K<br />

x0<br />

y0<br />

Centre 0.3828 0.3803<br />

0,4000<br />

0,3950<br />

0,3900<br />

0,3850<br />

0,3800<br />

0,3750<br />

0,3700<br />

0,3650<br />

0,3600<br />

0,4150<br />

0,3600<br />

0,4200<br />

MacAdam Ellipse: 4SDCM<br />

0,3650<br />

0,4250<br />

0,3700<br />

0,4300<br />

0,3750<br />

0,4350<br />

0,3800<br />

0,4400<br />

0,3850<br />

MacAdam Ellipse: 4SDCM<br />

0,4450<br />

0,3900<br />

0,4500<br />

0,3950<br />

0,4550<br />

0,4000<br />

norm. intensity [%]<br />

norm. intensity [%]<br />

0,07<br />

0,06<br />

0,05<br />

0,04<br />

0,03<br />

0,02<br />

0,01<br />

0,00<br />

380 420 460 500 540 580 620 660 700 740 780<br />

wave length [nm]<br />

0,07<br />

0,06<br />

0,05<br />

0,04<br />

0,03<br />

0,02<br />

0,01<br />

0,00<br />

380 420 460 500 540 580 620 660 700 740 780<br />

wave length [nm]<br />

PHASED OUT<br />

Data sheet 07/14-<strong>LED</strong>150-2<br />

Subject to change without notice.<br />

www.tridonic.com 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!