SAFETY DATA SHEET Ultraseal PC504/66 - AMI-CON

SAFETY DATA SHEET Ultraseal PC504/66 - AMI-CON SAFETY DATA SHEET Ultraseal PC504/66 - AMI-CON

ami.con.co.uk
from ami.con.co.uk More from this publisher
05.05.2015 Views

Revision Date 13/12/2012 Revision 8 Supersedes date 19/10/2010 SAFETY DATA SHEET Ultraseal PC504/66 According to Regulation (EC) No 1907/2006 SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING 1.1. Product identifier Product name Ultraseal PC504/66 1.2. Relevant identified uses of the substance or mixture and uses advised against Identified uses Sealant. 1.3. Details of the supplier of the safety data sheet Supplier Ultraseal International Godiva Place Coventry CV1 5PN UK +44 (0)24 7625 8444 +44 (0)24 7655 1402 MSDS@ultraseal.co.uk 1.4. Emergency telephone number +44 (0)20 8911 2530 SECTION 2: HAZARDS IDENTIFICATION 2.1. Classification of the substance or mixture Classification (1999/45/EEC) Xi;R36. R43. 2.2. Label elements Contains Labelling HYDROXYPROPYL METHACRYLATE Irritant Risk Phrases Safety Phrases 2.3. Other hazards R36 Irritating to eyes. R43 May cause sensitisation by skin contact. S24/25 Avoid contact with skin and eyes. S26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S37 Wear suitable gloves. S51 Use only in well-ventilated areas. S47/49A Keep only in original container at temperatures not exceeding 25°C. SU1 Protect from sunlight This product does not contain any PBT or vPvB substances. SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.2. Mixtures 1 / 9

Revision Date 13/12/2012<br />

Revision 8<br />

Supersedes date 19/10/2010<br />

<strong>SAFETY</strong> <strong>DATA</strong> <strong>SHEET</strong><br />

<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

According to Regulation (EC) No 1907/2006<br />

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING<br />

1.1. Product identifier<br />

Product name<br />

<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

1.2. Relevant identified uses of the substance or mixture and uses advised against<br />

Identified uses<br />

Sealant.<br />

1.3. Details of the supplier of the safety data sheet<br />

Supplier<br />

<strong>Ultraseal</strong> International<br />

Godiva Place<br />

Coventry<br />

CV1 5PN<br />

UK<br />

+44 (0)24 7625 8444<br />

+44 (0)24 7655 1402<br />

MSDS@ultraseal.co.uk<br />

1.4. Emergency telephone number<br />

+44 (0)20 8911 2530<br />

SECTION 2: HAZARDS IDENTIFICATION<br />

2.1. Classification of the substance or mixture<br />

Classification (1999/45/EEC) Xi;R36. R43.<br />

2.2. Label elements<br />

Contains<br />

Labelling<br />

HYDROXYPROPYL METHACRYLATE<br />

Irritant<br />

Risk Phrases<br />

Safety Phrases<br />

2.3. Other hazards<br />

R36<br />

Irritating to eyes.<br />

R43<br />

May cause sensitisation by skin contact.<br />

S24/25 Avoid contact with skin and eyes.<br />

S26<br />

In case of contact with eyes, rinse immediately with plenty of water and seek<br />

medical advice.<br />

S37<br />

Wear suitable gloves.<br />

S51<br />

Use only in well-ventilated areas.<br />

S47/49A<br />

Keep only in original container at temperatures not exceeding 25°C.<br />

SU1<br />

Protect from sunlight<br />

This product does not contain any PBT or vPvB substances.<br />

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS<br />

3.2. Mixtures<br />

1 / 9


<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

HYDROXYPROPYL METHACRYLATE 50 - 100%<br />

CAS-No.: Proprietary EC No.: 248-<strong>66</strong>6-3<br />

Classification (EC 1272/2008)<br />

Eye Irrit. 2 - H319<br />

Skin Sens. 1 - H317<br />

Classification (67/548/EEC)<br />

Xi;R36.<br />

R43.<br />

The Full Text for all R-Phrases and Hazard Statements are Displayed in Section 16.<br />

SECTION 4: FIRST AID MEASURES<br />

4.1. Description of first aid measures<br />

Inhalation<br />

Remove victim immediately from source of exposure. Provide rest, warmth and fresh air. Get medical attention if any discomfort<br />

continues.<br />

Ingestion<br />

DO NOT INDUCE VOMITING! NEVER MAKE AN UN<strong>CON</strong>SCIOUS PERSON VOMIT OR DRINK FLUIDS! Rinse mouth thoroughly. Get<br />

medical attention.<br />

Skin contact<br />

Remove affected person from source of contamination. Remove contaminated clothing. Wash the skin immediately with soap and water.<br />

Get medical attention if any discomfort continues.<br />

Eye contact<br />

Remove victim immediately from source of exposure. Make sure to remove any contact lenses from the eyes before rinsing. Promptly<br />

wash eyes with plenty of water while lifting the eye lids. Continue to rinse for at least 15 minutes and get medical attention.<br />

4.2. Most important symptoms and effects, both acute and delayed<br />

General information<br />

The severity of the symptoms described will vary dependant of the concentration and the length of exposure.<br />

Inhalation.<br />

Irritation of nose, throat and airway.<br />

Ingestion<br />

No specific symptoms noted.<br />

Skin contact<br />

Prolonged skin contact may cause redness and irritation.<br />

Eye contact<br />

Irritation of eyes and mucous membranes.<br />

4.3. Indication of any immediate medical attention and special treatment needed<br />

Treat Symptomatically.<br />

SECTION 5: FIREFIGHTING MEASURES<br />

5.1. Extinguishing media<br />

Extinguishing media<br />

Fire can be extinguished using: Water spray. Foam, carbon dioxide or dry powder.<br />

Unsuitable extinguishing media<br />

Do not use water jet as an extinguisher, as this will spread the fire.<br />

5.2. Special hazards arising from the substance or mixture<br />

Hazardous combustion products<br />

Thermal decomposition or combustion may liberate carbon oxides and other toxic gases or vapours.<br />

Specific hazards<br />

Carbon dioxide (CO2). Carbon monoxide (CO).<br />

5.3. Advice for firefighters<br />

Special Fire Fighting Procedures<br />

Containers close to fire should be removed immediately or cooled with water. Be aware of danger of explosion.<br />

Protective equipment for fire-fighters<br />

Self contained breathing apparatus and full protective clothing must be worn in case of fire.<br />

SECTION 6: ACCIDENTAL RELEASE MEASURES<br />

6.1. Personal precautions, protective equipment and emergency procedures<br />

2 / 9


For personal protection, see section 8.<br />

6.2. Environmental precautions<br />

<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

Do not discharge into drains, water courses or onto the ground.<br />

6.3. Methods and material for containment and cleaning up<br />

Ventilate well. Wear necessary protective equipment. Absorb in vermiculite, dry sand or earth and place into containers. Do not<br />

contaminate water sources or sewer. Inform Authorities if large amounts are involved.<br />

6.4. Reference to other sections<br />

For personal protection, see section 8. See section 11 for additional information on health hazards. Collect and dispose of spillage as<br />

indicated in section 13.<br />

SECTION 7: HANDLING AND STORAGE<br />

7.1. Precautions for safe handling<br />

Avoid spilling, skin and eye contact.<br />

7.2. Conditions for safe storage, including any incompatibilities<br />

Store in tightly closed original container in a dry, cool and well-ventilated place. Keep in original container. Store below 25°C. Protect from<br />

freezing and direct sunlight.<br />

7.3. Specific end use(s)<br />

The identified uses for this product are detailed in Section 1.2.<br />

SECTION 8: EXPOSURE <strong>CON</strong>TROLS/PERSONAL PROTECTION<br />

8.1. Control parameters<br />

Ingredient Comments<br />

No exposure limits noted for ingredient(s).<br />

8.2. Exposure controls<br />

Protective equipment<br />

Process conditions<br />

Provide eyewash station.<br />

Engineering measures<br />

Well-ventilated area.<br />

Respiratory equipment<br />

No specific recommendation made, but respiratory protection may still be required under exceptional circumstances when excessive air<br />

contamination exists. In case of inadequate ventilation or when the product is heated, use suitable respiratory equipment with gas filter<br />

(type A2).<br />

Hand protection<br />

Nitrile gloves are recommended. Be aware that the liquid may penetrate the gloves. Frequent change is advisable.<br />

Eye protection<br />

Use approved safety goggles or face shield.<br />

Other Protection<br />

Wear appropriate clothing to prevent any possibility of skin contact.<br />

Hygiene measures<br />

DO NOT SMOKE IN WORK AREA! Wash hands at the end of each work shift and before eating, smoking and using the toilet. Wash<br />

promptly if skin becomes wet or contaminated. Promptly remove any clothing that becomes contaminated. When using do not eat, drink<br />

or smoke.<br />

Environmental Exposure Controls<br />

Keep container tightly sealed when not in use.<br />

SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES<br />

9.1. Information on basic physical and chemical properties<br />

Appearance<br />

Colour<br />

Liquid<br />

Light (or pale). Straw.<br />

3 / 9


Odour<br />

Solubility<br />

Initial boiling point and boiling range<br />

Not available.<br />

Melting point (°C)<br />

Not available.<br />

Mild (or faint).<br />

Forms an emulsion.<br />

Relative density 1.005 - 1.015 @ 20 °c<br />

Vapour density (air=1)<br />

Not available.<br />

Evaporation rate<br />

Not available.<br />

pH-Value, Conc. Solution<br />

Not available.<br />

Viscosity 32 - 34 s @ 20 °c<br />

Solubility Value (G/100G H2O@20°C)<br />

Not available.<br />

Decomposition temperature (°C)<br />

Not available.<br />

Odour Threshold, Lower<br />

Not available.<br />

Odour Threshold, Upper<br />

Not available.<br />

Flash point<br />

Auto Ignition Temperature (°C)<br />

Not available.<br />

Flammability Limit - Lower(%)<br />

Not available.<br />

Flammability Limit - Upper(%)<br />

Not available.<br />

Partition Coefficient<br />

(N-Octanol/Water)<br />

Not available.<br />

Explosive properties<br />

Not available.<br />

Oxidising properties<br />

Not available.<br />

9.2. Other information<br />

Not available.<br />

96 C<br />

SECTION 10: STABILITY AND REACTIVITY<br />

10.1. Reactivity<br />

10.2. Chemical stability<br />

Stable under normal temperature conditions.<br />

10.3. Possibility of hazardous reactions<br />

Hazardous Polymerisation<br />

May polymerize violently.<br />

Polymerisation Description<br />

<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

Store in original container to avoid contamination. Polymerises easily with evolution of heat. Keep cool. Avoid heat. Avoid light.<br />

10.4. Conditions to avoid<br />

Polymerises when heated. Avoid heat, flames and other sources of ignition. Avoid exposure to high temperatures or direct sunlight. Avoid<br />

contact with acids and oxidising substances.<br />

10.5. Incompatible materials<br />

Materials To Avoid<br />

Strong oxidising substances. Strong reducing agents. Inorganic peroxides. Organic peroxides/hydroperoxides. Strong acids. Strong<br />

alkalis.<br />

10.6. Hazardous decomposition products<br />

Fire creates: Carbon monoxide (CO). Carbon dioxide (CO2).<br />

4 / 9


<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

SECTION 11: TOXICOLOGICAL INFORMATION<br />

11.1. Information on toxicological effects<br />

Toxicological information<br />

No information available.<br />

Germ cell mutagenicity:<br />

This substance has no evidence of mutagenic properties.<br />

Carcinogenicity:<br />

This substance has no evidence of carcinogenic properties.<br />

Reproductive Toxicity:<br />

This substance has no evidence of toxicity to reproduction.<br />

Inhalation<br />

May cause irritation to the respiratory system.<br />

Skin contact<br />

Irritating to skin. May cause sensitisation by skin contact.<br />

Eye contact<br />

Irritating to eyes.<br />

Route of entry<br />

Skin and/or eye contact.<br />

Target Organs<br />

Skin Eyes<br />

Medical Symptoms<br />

Skin irritation. Irritation of eyes and mucous membranes.<br />

Toxicological information on ingredients.<br />

5 / 9


Toxic Dose 1 - LD 50<br />

> 2000 mg/kg (oral rat)<br />

<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

HYDROXYPROPYL METHACRYLATE<br />

Acute toxicity:<br />

Acute Toxicity (Dermal LD50)<br />

> 5000 mg/kg Rat<br />

Respiratory or skin sensitisation:<br />

Sensitising.<br />

Germ cell mutagenicity:<br />

Based on available data the classification criteria are not met.<br />

Carcinogenicity:<br />

Estimated Value<br />

This substance has no evidence of carcinogenic properties.<br />

Reproductive Toxicity:<br />

No evidence of reproductive toxicity in animal studies<br />

Specific target organ toxicity - single exposure:<br />

Not classified as a specific target organ toxicant after a single exposure.<br />

Specific target organ toxicity - repeated exposure:<br />

STOT - Repeated exposure<br />

NOAEL 300 mg/kg Oral Rat<br />

Not classified as a specific target organ toxicant after repeated exposure.<br />

Aspiration hazard:<br />

Not anticipated to present an aspiration hazard based on chemical structure.<br />

Inhalation<br />

No specific health warnings noted.<br />

Ingestion<br />

No specific health warnings noted.<br />

Skin contact<br />

May cause sensitisation by skin contact.<br />

Eye contact<br />

Irritating to eyes.<br />

Route of entry<br />

Skin and/or eye contact.<br />

Target Organs<br />

Skin Eyes<br />

Irritation of eyes and mucous membranes.<br />

SECTION 12: ECOLOGICAL INFORMATION<br />

12.1. Toxicity<br />

Acute Toxicity - Fish<br />

Not available.<br />

Acute Toxicity - Aquatic Invertebrates<br />

Not available.<br />

Acute Toxicity - Aquatic Plants<br />

Not available.<br />

Acute Toxicity - Microorganisms<br />

Not available.<br />

Chronic Toxicity - Fish Early life Stage<br />

Not available.<br />

6 / 9


Chronic Toxicity - Aquatic Invertebrates<br />

Not available.<br />

Acute Toxicity - Terrestrial<br />

Not available.<br />

<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

Ecological information on ingredients.<br />

HYDROXYPROPYL METHACRYLATE<br />

Acute Toxicity - Fish<br />

LC50 48 hours 493 mg/l Leuciscus idus (Golden orfe)<br />

Acute Toxicity - Aquatic Invertebrates<br />

EC50 48 hours 380 mg/l Daphnia magna<br />

NOEC 48 hours 24.1 mg/l Daphnia magna<br />

Acute Toxicity - Aquatic Plants<br />

EC50 72 hours > 97.2 mg/l Freshwater algae<br />

NOEC 72 hours 97.2 mg/l Freshwater algae<br />

12.2. Persistence and degradability<br />

Degradability<br />

The product is expected to be biodegradable.<br />

Ecological information on ingredients.<br />

Degradability<br />

HYDROXYPROPYL METHACRYLATE<br />

Biodegradable according to the appropriate OECD test. This product is expected to be removed in a wastewater treatment plant. Oxides rapidly<br />

by photochemical reactions in air<br />

12.3. Bioaccumulative potential<br />

Bioaccumulative potential<br />

Bioaccumulation is unlikely to be significant because of the low water solubility of this product.<br />

Partition coefficient<br />

Not available.<br />

Ecological information on ingredients.<br />

Bioaccumulative potential<br />

HYDROXYPROPYL METHACRYLATE<br />

Bioaccumulation is unlikely to be significant because of the low water solubility of this product.<br />

Partition coefficient<br />

Pow 0.97<br />

12.4. Mobility in soil<br />

Mobility:<br />

The product has poor water-solubility.<br />

Ecological information on ingredients.<br />

Mobility:<br />

Mobile.<br />

12.5. Results of PBT and vPvB assessment<br />

Not relevant<br />

Ecological information on ingredients.<br />

HYDROXYPROPYL METHACRYLATE<br />

This product does not contain any PBT or vPvB substances.<br />

12.6. Other adverse effects<br />

Not known.<br />

Ecological information on ingredients.<br />

HYDROXYPROPYL METHACRYLATE<br />

Not available.<br />

HYDROXYPROPYL METHACRYLATE<br />

7 / 9


<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

SECTION 13: DISPOSAL <strong>CON</strong>SIDERATIONS<br />

13.1. Waste treatment methods<br />

Dispose of waste and residues in accordance with local authority requirements.<br />

SECTION 14: TRANSPORT INFORMATION<br />

General<br />

14.1. UN number<br />

The product is not covered by international regulation on the transport of dangerous goods (IMDG, IATA,<br />

ADR/RID).<br />

Not applicable.<br />

14.2. UN proper shipping name<br />

Not applicable.<br />

14.3. Transport hazard class(es)<br />

Not applicable.<br />

Transport Labels<br />

No transport warning sign required.<br />

14.4. Packing group<br />

Not applicable.<br />

14.5. Environmental hazards<br />

Environmentally Hazardous Substance/Marine Pollutant<br />

No.<br />

14.6. Special precautions for user<br />

Not applicable.<br />

14.7. Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code<br />

Not applicable.<br />

SECTION 15: REGULATORY INFORMATION<br />

15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture<br />

Statutory Instruments<br />

The Chemicals (Hazard Information and Packaging for Supply) Regulations 2009 (S.I 2009 No. 716).<br />

Approved Code Of Practice<br />

Classification and Labelling of Substances and Preparations Dangerous for Supply.<br />

Guidance Notes<br />

CHIP for everyone HSG(108).<br />

EU Legislation<br />

Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration,<br />

Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive<br />

1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive<br />

76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC, including amendments.<br />

15.2. Chemical Safety Assessment<br />

No chemical safety assessment has been carried out.<br />

SECTION 16: OTHER INFORMATION<br />

Revision Date 13/12/2012<br />

Revision 8<br />

Supersedes date 19/10/2010<br />

Risk Phrases In Full<br />

R36<br />

R43<br />

Irritating to eyes.<br />

May cause sensitisation by skin contact.<br />

8 / 9


Hazard Statements In Full<br />

H319<br />

H317<br />

Causes serious eye irritation.<br />

May cause an allergic skin reaction.<br />

<strong>Ultraseal</strong> <strong>PC504</strong>/<strong>66</strong><br />

Disclaimer<br />

The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. <strong>Ultraseal</strong> International shall not<br />

be held liable for any damage resulting from contact with or handling of the above product.<br />

9 / 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!