20 Model 350 I.S. and Model 355 I.S. Service Manual
4 Operation The Model 350 I.S. and 355 I.S. provide many options for check-weighing, parts counting and filling etc. The functions described in this section are not available until enabled within the setup parameters. Contact your GSE distributor to configure the indicator for a specific operation. 4.1 Entering a Tare Value (Model 350 I.S.) If a tare value is known, it is possible to enter that value into the tare register. Follow the steps below. 1. From the gross mode use the [SELECT] key to scroll in the first number. 2. Use the [PRINT] key to scroll in the first number. 3. Press the [UNITS] key to move to the next digit. 4. Repeat steps 2 and 3 until the desired number is showing on the display. 5. Press the [TARE] key to accept the entered tare value. 4.2 Entering a Tare Value (Model 355 I.S.) If a tare value is known, it is possible to enter that value into the tare register. Follow the step below. 1. Key in the known tare value with the numeric keys and press [TARE]. The display will access the net mode. 4.3 Enter an ID Number If the ID parameter has been enabled previously, a number may be entered to print on a ticket. Follow the instructions below to enter an ID number. 1. Press the [PRINT] key from the weigh mode. The display will show the current ID number if one has been entered previously. 2. Key in the desire ID number (numeric and/or alphanumeric) and press [TARE] (Model 350 I.S.) or [ENTER] (Model 355 I.S.). This will print a ticket. -or- 2a. If the ID number shown is acceptable simply press [TARE] (Model 350 I.S.) or [ENTER] (Model 355 I.S.). This will print a ticket which includes the entered ID number. Model 350 I.S. and 355 I.S. User Instructions 21
- Page 1 and 2: Model 350I.S. and Model 355I.S. Ins
- Page 3 and 4: Table of Contents Chapter 1 General
- Page 5 and 6: 1 General information and warnings
- Page 7 and 8: 1.3.3 Safe Handling of Equipment wi
- Page 9 and 10: 1.8 FCC and EMC Declarations of Com
- Page 11 and 12: 2 Installation The Model 350/355 I.
- Page 13 and 14: 2.3.1 Model 350 I.S. Figure 2.1 Mod
- Page 15 and 16: 2.4 AC and DC Powered 2.4.1 DC Oper
- Page 17 and 18: 3 Display and Keypad 3.1 Display Th
- Page 19 and 20: Key Press Weigh Mode Count Mode Bac
- Page 21: 3.2.3 Weigh Mode Functions The Mode
- Page 25 and 26: To enter the date from the Enter~da
- Page 27 and 28: 4.6 Percentage Checkweigh This feat
- Page 29 and 30: Example: Target of 20 2a. Press [PR
- Page 31 and 32: m DISPLAY READS > 2 . 2c. Press [PR
- Page 33 and 34: 4.9.1 Enter a Target Pressing [TARE
- Page 35 and 36: 4.9.4 Discharge Example With a syst
- Page 37 and 38: Annunciators Status Annunciator Sta
- Page 39 and 40: 4.11.2 Start Checkweighing The chec
- Page 41 and 42: 4.12.3 Target Deviation Checkweighi
- Page 43 and 44: 5 Troubleshooting The Model 350/355
- Page 45 and 46: 6 Specifications Performance Full S
- Page 48: Avery Weigh-Tronix USA 1000 Armstro
20<br />
Model 350 I.S. and Model <strong>355</strong> I.S. Service <strong>Manual</strong>