3.2 Keypads 3.2.1 Model 350 I.S. Keypad The Model 350 I.S. offers a sealed 5-button elastomer keypad which is used for operator input. Each key is assigned two distinct functions. Various key combinations are also used. Each key has secondary functions; allowing an operator to enter target values, perform piece samples, access setup parameters, etc. ZERO CLR PRINT UNITS TARE SELECT ON OFF Figure 3.3 Model 350 I.S. Keypad Key Press Weigh Mode Count Mode Performs a gross zero function and/or clears an entry in progress. Hold this key on power-up to turn on the display if in sleep mode. Performs a print function and/or 'scrolls' through digits during setpoint entry. Performs a quantity zero function and/or clears an entry in progress. Performs a print function and/or 'scrolls' through digits during setpoint entry.' Toggles between 'lb' and 'kg' and/ or advances cursor to next entry position. Toggles through standard sample sizes and/or begins a new sample entry. Performs an auto-tare function (if enabled) and/or accepts an entry in progress. Toggles between display modes and/or restores power to the indicator (if auto-shutoff enabled). Performs an auto-tare function and requests a piece sample and/or accepts an entry in progress. Toggles between display modes and/or restores power to the indicator (if auto-shutoff enabled). Absolute clear - clears an entry in progress and/or clears the value of a parameter. No function. 16 Model 350 I.S. and Model 355 I.S. Service Manual
Key Press Weigh Mode Count Mode Backspace - erases the right-most digit during data entry. Backspace - erases the rightmost digit during sample entry. Extended gross. Extended gross. Reverse character scroll during data entry. Reverse character scroll during sample entry. Turn off indicator by holding key for approximately 1 second. Turn off indicator by holding key for approximately 1 second. 3.2.2 Model 355 I.S. Keypad The Model 355 I.S. keypad performs different functions in the Weigh Mode and the Count Mode. The numeric keys make entering values such as tare or average piece weight easier. ON TARGET ZERO PRINT SELECT 1 2 3 OFF TARE START UNITS 4 5 7 8 6 9 STOP SAMPLE ENTER YES CLR 0 NO Figure 3.4 Model 355 I.S. Keypad Model 350 I.S. and Model 355 I.S. Service Manual 17
- Page 1 and 2: Model 350I.S. and Model 355I.S. Ins
- Page 3 and 4: Table of Contents Chapter 1 General
- Page 5 and 6: 1 General information and warnings
- Page 7 and 8: 1.3.3 Safe Handling of Equipment wi
- Page 9 and 10: 1.8 FCC and EMC Declarations of Com
- Page 11 and 12: 2 Installation The Model 350/355 I.
- Page 13 and 14: 2.3.1 Model 350 I.S. Figure 2.1 Mod
- Page 15 and 16: 2.4 AC and DC Powered 2.4.1 DC Oper
- Page 17: 3 Display and Keypad 3.1 Display Th
- Page 21 and 22: 3.2.3 Weigh Mode Functions The Mode
- Page 23 and 24: 4 Operation The Model 350 I.S. and
- Page 25 and 26: To enter the date from the Enter~da
- Page 27 and 28: 4.6 Percentage Checkweigh This feat
- Page 29 and 30: Example: Target of 20 2a. Press [PR
- Page 31 and 32: m DISPLAY READS > 2 . 2c. Press [PR
- Page 33 and 34: 4.9.1 Enter a Target Pressing [TARE
- Page 35 and 36: 4.9.4 Discharge Example With a syst
- Page 37 and 38: Annunciators Status Annunciator Sta
- Page 39 and 40: 4.11.2 Start Checkweighing The chec
- Page 41 and 42: 4.12.3 Target Deviation Checkweighi
- Page 43 and 44: 5 Troubleshooting The Model 350/355
- Page 45 and 46: 6 Specifications Performance Full S
- Page 48: Avery Weigh-Tronix USA 1000 Armstro
3.2 Keypads<br />
3.2.1 Model 350 I.S. Keypad<br />
The Model 350 I.S. offers a sealed 5-button elastomer keypad which is used for<br />
operator input. Each key is assigned two distinct functions. Various key combinations<br />
are also used. Each key has secondary functions; allowing an operator to enter target<br />
values, perform piece samples, access setup parameters, etc.<br />
ZERO<br />
CLR<br />
PRINT<br />
UNITS<br />
TARE<br />
SELECT<br />
ON<br />
OFF<br />
Figure 3.3 Model 350 I.S. Keypad<br />
Key Press <strong>Weigh</strong> Mode Count Mode<br />
Performs a gross zero function<br />
and/or clears an entry in progress.<br />
Hold this key on power-up to turn<br />
on the display if in sleep mode.<br />
Performs a print function and/or<br />
'scrolls' through digits during<br />
setpoint entry.<br />
Performs a quantity zero function<br />
and/or clears an entry in<br />
progress.<br />
Performs a print function and/or<br />
'scrolls' through digits during<br />
setpoint entry.'<br />
Toggles between 'lb' and 'kg' and/<br />
or advances cursor to next entry<br />
position.<br />
Toggles through standard sample<br />
sizes and/or begins a new<br />
sample entry.<br />
Performs an auto-tare function (if<br />
enabled) and/or accepts an entry<br />
in progress.<br />
Toggles between display modes<br />
and/or restores power to the<br />
indicator (if auto-shutoff enabled).<br />
Performs an auto-tare function<br />
and requests a piece sample<br />
and/or accepts an entry in<br />
progress.<br />
Toggles between display modes<br />
and/or restores power to the<br />
indicator (if auto-shutoff enabled).<br />
Absolute clear - clears an entry in<br />
progress and/or clears the value<br />
of a parameter.<br />
No function.<br />
16<br />