6(a) Hire and labour charges for shuttering for foundation concrete side shuttering of concrete floor /lintels slab etc. where no vertical props are required fitting and fixing and skirting out after completion of work 25mm to 30mm thick shuttering without staging in foundation etc Sqm 2353 (b) Hire and labour charges for shuttering with centering and necessary staging up to 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slab, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works .(up to roof of ground floor) . a. 25mm to 30mm thick wooden shuttering as per decision & direction E.I.C Sqm 1884 7 Reinforcement for reinforced concrete work in the all sorts of structure including distribution bars, stirrups binders etc. including supply of rods initial straightening and removal of loose rust cutting to required length, hooking and bending to correct shape placing in proper position and binding with 16 gauge black annealed wire at every intersection complete as per drawing and direction. Tor / Mild steel MT 39 8 125mm thick brick work with 1 st class bricks in cement mortar (4:1) in ground floor Sqm 2608 9 Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corner as directed and raking out joints or roughening of concrete surface including throating, nosing and drip course where necessary (a) 20 mm thick plaster with 6:1 mortar (inside wall) Sqm 4683 (b) 15 mm thick plaster with 6:1 mortar (out side wall) Sqm 4407 10 Net cement punning about 1.5mm thick in wall dado, window, sils, floor, drain etc. Sqm 585.00 11 Cement washing including cleaning and smoothening surface thoroughly (cement to be used 15 kg /100 Sqm. of surface for two coat. Sqm 8505 12 Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly as per manufacturer’s specification In ground floor. iii. Two coats Sqm 8505 13 Earth work in filling in foundation trenches with good earth in layers not exceeding 15cm including watering and ramming etc. layer by layer complete With earth obtained from excavation of foundation Cum 1240 14 M.S gate of jail type as per approved design made of strong M.S frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet ( not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineering – In – Charge. Quintal 61.6 15 Locking arrangement for jail type doors including supplying fitting and fixing in position complete as per approved design. Kg 100 Total Bid Price (In Figures): Total Bid Price (In Words): 130
Note: (1) Item for which no rate or price has been entered in will not be paid for by the Employer when executed and shall be deemed covered by the other rates and prices in the Bill of Quantities (refer: ITB Clause 13.2 and GCC Clause 43.3). (2) Unit rates and prices shall be quoted by the bidder in Indian rupee [ITB Clause 14.1]. (3) Where there is a discrepancy between the rate in figures and words, the rates in words will govern. [ITB Clause 27.1(a) ] 4) Where there is a discrepancy between the unit rate and the line item total resulting from multiplying the unit rate by quantity, the unit rate quoted shall govern [ITB Clause 27.1 (b)]. 131
- Page 79 and 80: DETAILED TECHNICAL SPECIFICATION FO
- Page 81 and 82: 6.0 SHORING WORKS 6.1 General: Shor
- Page 83 and 84: When testing a pipeline hydraulical
- Page 85 and 86: (i) (ii) (iii) procurement & supply
- Page 87 and 88: the worst weather and flooding cond
- Page 89 and 90: All valves shall be provided with c
- Page 91 and 92: SECTION 6: Layout Drawings of the w
- Page 93 and 94: SCHEDULE OF QUANTITIES FOR GUEST HO
- Page 95 and 96: 2 Brick work with 1st class bricks
- Page 97 and 98: smooth finish acrylic exterior emul
- Page 99 and 100: complete.(Payment to be made on bas
- Page 101 and 102: approved brand (size not less than
- Page 103 and 104: and including smoothening surface b
- Page 105 and 106: 8.1 5/6 amps switch Each 30 8.2 15/
- Page 107 and 108: sets of G.I. nut bolt & spring wash
- Page 109 and 110: power unit having suitable rating S
- Page 111 and 112: as required. 19.0 Installation of e
- Page 113 and 114: 40.2 63 Amp DP Each 1 41.0 Providin
- Page 115 and 116: (i) 590 mm X 390 mm X 380 mm 9 Supp
- Page 117 and 118: clamps 750 mm long 4 Installation o
- Page 119 and 120: all specials . No separate payment
- Page 121 and 122: stacking the spills within a lead o
- Page 123 and 124: cc manhole cover of approved make s
- Page 125 and 126: acing for concrete slabs , beams, a
- Page 127 and 128: 4.0 Laying and fixing of one number
- Page 129: The rate shall be inclusive of supp
- Page 133 and 134: Forms of Securities Acceptable form
- Page 135 and 136: PERFORMANCE BANK GUARANTEE To: ____
- Page 137: BANK GUARANTEE FOR ADVANCE PAYMENT
6(a) Hire and labour charges <strong>for</strong> shuttering <strong>for</strong> foundation<br />
concrete side shuttering of concrete floor /lintels slab etc.<br />
where no vertical props are required fitting and fixing and<br />
skirting out after completion of work 25mm to 30mm thick<br />
shuttering <strong>with</strong>out staging in foundation etc Sqm 2353<br />
(b) Hire and labour charges <strong>for</strong> shuttering <strong>with</strong> centering and<br />
necessary staging up to 4m using approved stout props and<br />
thick hard wood planks of approved thickness <strong>with</strong> required<br />
bracing <strong>for</strong> concrete slab, beams, columns, lintels curved or<br />
straight including fitting, fixing and striking out after<br />
completion of works .(up to roof of ground floor) .<br />
a. 25mm to 30mm thick wooden shuttering as per decision<br />
& direction E.I.C Sqm 1884<br />
7 Rein<strong>for</strong>cement <strong>for</strong> rein<strong>for</strong>ced concrete work in the all sorts<br />
of structure including distribution bars, stirrups binders etc.<br />
including supply of rods initial straightening and removal of<br />
loose rust cutting to required length, hooking and bending<br />
to correct shape<br />
placing in proper position and binding <strong>with</strong> 16 gauge black<br />
annealed wire at every intersection complete as per drawing<br />
and direction. Tor / Mild steel MT 39<br />
8 125mm thick brick work <strong>with</strong> 1 st class bricks in cement<br />
mortar (4:1) in ground floor Sqm 2608<br />
9 Plaster ( to wall, floor, ceiling etc.) <strong>with</strong> sand and cement<br />
mortar including rounding off or chamfering corner as<br />
directed and raking out joints or roughening of concrete<br />
surface including throating, nosing and drip course where<br />
necessary<br />
(a) 20 mm thick plaster <strong>with</strong> 6:1 mortar (inside wall) Sqm 4683<br />
(b) 15 mm thick plaster <strong>with</strong> 6:1 mortar (out side wall) Sqm 4407<br />
10 Net cement punning about 1.5mm thick in wall dado,<br />
window, sils, floor, drain etc. Sqm 585.00<br />
11 Cement washing including cleaning and smoothening<br />
surface thoroughly (cement to be used 15 kg /100 Sqm. of<br />
surface <strong>for</strong> two coat. Sqm 8505<br />
12 Applying decorative cement based paint of approved quality<br />
after preparing the surface including scraping the same<br />
thoroughly as per manufacturer’s specification In ground<br />
floor.<br />
iii. Two coats Sqm 8505<br />
13 Earth work in filling in foundation trenches <strong>with</strong> good earth<br />
in layers not exceeding 15cm including watering and<br />
ramming etc. layer by layer complete<br />
With earth obtained from excavation of foundation Cum 1240<br />
14 M.S gate of jail type as per approved design made of strong<br />
M.S frame work, intermediate stiffeners and round / square<br />
bars or angles. M.S. sheet ( not less than 14 gauge) gussets,<br />
cleats etc. including necessary riveting, bolting, welding,<br />
locking and hanging arrangements, fitting and fixing<br />
complete as per direction of the Engineering – In – Charge. Quintal 61.6<br />
15 Locking arrangement <strong>for</strong> jail type doors including supplying<br />
fitting and fixing in position complete as per approved<br />
design. Kg 100<br />