all specials . No separate payment will be made <strong>for</strong><br />
accessories, specials.)<br />
15 mm dia medium duty Mtrs 35.00<br />
20 mm dia medium duty Mtrs 40.00<br />
25 mm dia medium duty Mtrs 50.00<br />
32 mm dia medium duty Mtrs 40.00<br />
50 mm dia medium duty Mtrs 40.00<br />
2 Supplying, fitting and fixing gunmetal wheel valve of<br />
approved brand and make tested to 21 kg per sq. cm. (<strong>for</strong><br />
water lines only).<br />
20 mm dia Each 8.00<br />
25 mm dia Each 4.00<br />
32 mm dia Each 2.00<br />
3 Supply, fitting & fixing approved quality P.V.C. water<br />
storage tanks <strong>with</strong> closed top <strong>with</strong> lid (black) multilayer<br />
(a) 5,000 litres capacity Each 1.00<br />
D<br />
SOIL/WASTE/VENT/PIPES & SPECIALS<br />
1 Supply of UPVC pipes (B type) & fittings con<strong>for</strong>ming to IS<br />
- 13592 - 1992<br />
Single Socketed 3 Meter Length<br />
75 mm dia Mtrs 24.00<br />
110 mm dia Mtrs 115.00<br />
Fittings<br />
110 X 110 P trap<br />
75 mm<br />
110 X 110 S trap<br />
75 mm<br />
each 6.00<br />
each 7.00<br />
Double Y<br />
110 mm dia each 4.00<br />
Door Y (LH) & (RH)<br />
110 mm dia each 6.00<br />
Door Bend (T.S.)<br />
110 mm dia each 16.00<br />
Bend 87.5 degree<br />
(a) 110 mm dia each 35.00<br />
Vent<br />
Cowl Nos 6.00<br />
(b) 110 mm<br />
2 Labour <strong>for</strong> fitting and fixing U.P.V.C. pipes <strong>for</strong> above<br />
ground work including cost of jointing materials etc. fitting<br />
and fixing all necessary specials, cutting pipes, cutting holes<br />
in walls or R.C. floor where necessary and mending good<br />
all damages excluding the cost of masonry or concrete<br />
work, if necessary, but including the cost and fitting and<br />
fixing holder bat clamps (any floor) or <strong>for</strong> underground<br />
work including cutting trenches upto 1.5 metre and refilling<br />
the same complete as per direction of Engineer-in-charge . (<br />
Payment will be made on centre line measurement of the<br />
total pipeline including specials )<br />
(A) Above ground<br />
(i) 75 mm dia. Mtr 24.00<br />
(ii) 110 mm dia. Mtr 115.00<br />
3 Supplying, fitting and fixing yard gully <strong>with</strong> approved H.C.I Each 10<br />
grating<br />
complete<br />