20.0 Extra <strong>for</strong> fixing the louvers / shutters complete <strong>with</strong> frame<br />

<strong>for</strong> a exhaust fan of all sizes.<br />

Each 5<br />

21.0 Providing and fixing following capacity TP&N<br />

disconnector fuse switch unit inside the existing panel board<br />

<strong>with</strong> ISI marked HRC fuses including drilling holes in<br />

cubicle panel, making connections, etc. as required.<br />

21.1 32 Amp TP&N Each 1<br />

21.2 63 Amp TP&N Each 1<br />

22.0 Supplying and fixing following way, single pole and<br />

neutral, sheet steel, MCB distribution board, 240 volts, on<br />

surface/ recess, complete <strong>with</strong> tinned copper bus bar,<br />

neutral bus bar, earth bar, din bar, interconnections, powder<br />

painted including earthing etc. as required. (But <strong>with</strong>out<br />

MCB / RCCB / Isolator)<br />

22.1 2 + 4 way, Double door Each 2<br />

22.2 2 + 6 way, Double door Each 1<br />

22.3 2 + 8 way, Double door Each 3<br />

22.4 2 + 12 way, Double door Each 1<br />

23.0 Supplying and fixing following way, horizontal type three<br />

pole and neutral, sheet steel, MCB distribution board, 415<br />

volts, on surface / recess, complete <strong>with</strong> tinned copper bus<br />

bar, neutral bus bar, earth bar, din bar, interconnections,<br />

powder painted including earthing etc. as required. (But<br />

<strong>with</strong>out MCB / RCCB / Isolator)<br />

4 way (4 + 12), Double door Each 1<br />

24.0 Supplying and fixing 5 amps to 32 amps rating, 240/415<br />

volts, "C" curve, miniature circuit breaker suitable <strong>for</strong><br />

inductive load of following poles in the existing MCB DB<br />

complete <strong>with</strong> connections, testing and commissioning etc.<br />

as required.<br />

24.1 Single pole Each 34<br />

24.2 Double pole Each 5<br />

24.3 Triple pole Each 1<br />

24.4 Four pole Each 1<br />

25.0 Supplying and fixing single pole blanking plate in the<br />

existing MCB DB complete etc. as required.<br />

26.0 Providing and fixing M.V. danger notice plate of 200 mm X<br />

150 mm, made of mild steel, at least 2 mm thick, and<br />

vitreous enameled white on both sides, and <strong>with</strong> inscription<br />

in single red colour on front side as required.<br />

27.0 Earthing <strong>with</strong> G.I. earth pipe 4.5 metre long, 40 mm dia<br />

including accessories, and providing masonry enclosure<br />

<strong>with</strong> cover plate having locking arrangement and watering<br />

pipe etc. <strong>with</strong> charcoal / coke and salt as required.<br />

Each 4<br />

Each 1<br />

Each 1<br />

28.0 Supplying and laying 6 SWG G.I. wire at 0.50 metre below<br />

ground level <strong>for</strong> conductor earth electrode, including<br />

connection / termination <strong>with</strong> GI thimble etc. as required.<br />

Metre 5<br />

29.0 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre<br />

below ground as strip earth electrode, including connection<br />

/ terminating <strong>with</strong> G.I. nut, bolt, spring, washer etc. as<br />

required. (Jointing shall be done by overlapping and <strong>with</strong> 2 Metre 5<br />