SeaMach Reverse Cycle <strong>Air</strong> Conditioners<br />
To enter the Set Up mode, gently push & release on the center of the 4 position touch pad. During SET<br />
UP, if the touch pad is not pressed for 4 seconds, the thermostat /controller will exit the SET UP mode.<br />
To return to SET UP, press the center of the touch pad. Press & release the right side of the touch pad<br />
repeatedly to return to your previous point in the SET UP mode.<br />
Temperature Set Point Set Up<br />
To adjust the temperature set point, gently push on the top of<br />
the touch pad to raise the set point temperature or on the<br />
bottom to lower the set point temperature. Note: the<br />
temperature scale – ºF or ºC – can be selected in step 5.<br />
After selecting the desired set point, press on the right side<br />
once of the touch pad to move to Operating Mode Set Up.<br />
Operating Mode Set Up<br />
The SeaMach unit has five modes of operation – Auto, Cool Only, Heat Only, Fan Only and the<br />
Dehumidification Mode. Press either the top or the bottom of the touch pad to select the desired mode.<br />
Note: the Auto mode is recommended for normal operation.<br />
Auto – The SeaMach unit will automatically heat or cool, depending upon the set point temperature.<br />
Cool – The SeaMach unit will only operate in the cooling mode.<br />
Heat - The SeaMach unit will only operate in the heating mode.<br />
Fan Only – The fan in the SeaMach unit will run to provide air circulation in the cabin, but no heating<br />
or cooling will be provided.<br />
Dehumidification Mode – This mode is recommended when the boat is going to be unoccupied for<br />
more than 48 hours during warm or hot seasons. In the Dehumidification mode, the SeaMach unit will<br />
operate in the cooling mode for 15 minutes every 6 hours to remove moisture from the cabin. The unit<br />
will only operate if the cabin temperature is 67°F (19°C) or above.<br />
To proceed to Fan Mode Set Up, press the right side of the touch pad.<br />
SeaMach Owner’s Manual 5/05 Page 7 of 24