ASTREE Electronic Tongue
ASTREE Electronic Tongue
ASTREE Electronic Tongue
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Cutting edge technology for taste development of formulation!<br />
<strong>ASTREE</strong><br />
><br />
<strong>Electronic</strong> <strong>Tongue</strong><br />
Objective & Safe Taste Measurement - Fingerprint Liquid Analyzer<br />
> Food & Beverage<br />
> Nutraceutical & Pharmaceutical<br />
> Tobacco
T aste Masking<br />
> ><br />
<strong>ASTREE</strong><br />
the key tool for taste assessment<br />
><br />
S Optimize the taste masking efficiency of active<br />
(NCE / Nutraceutical) formulation even before<br />
safety assessment study<br />
S Assess the impact on taste of every ingredient<br />
S Measure the bitterness intensity and improve<br />
your formulation design / selection<br />
S Enlarge your portfolio of choice of ingredients<br />
without a systematic use of sensory panel<br />
Improve your formulation<br />
for better consumer likings<br />
C2: 24.69 %<br />
400<br />
300<br />
200<br />
100<br />
P4<br />
0<br />
Good<br />
Masking<br />
F4<br />
P3<br />
P1<br />
P2<br />
F3<br />
Discrimination index: 90<br />
Increase and change<br />
of masking agent<br />
in placebo formulation<br />
Increase and<br />
change of<br />
masking agent<br />
in active formulation<br />
-100 0 500 1000 1500<br />
C1: 70.94 %<br />
Comparison of formulation with active drug (F)<br />
and the corresponding formulation without<br />
active substance (placebo P). When the distance<br />
is reduced, the taste masking has been improved.<br />
F2<br />
F1<br />
S helf Life<br />
S Analyze taste evolution and stability of oral<br />
formulations according to various storage conditions,<br />
time or packaging<br />
C2: 3.57 %<br />
60.000<br />
40.000<br />
20.000<br />
0.000<br />
-20.000<br />
30°C<br />
25°C<br />
Discrimination index: 93<br />
Temperature<br />
increase<br />
25°C<br />
30°C<br />
5°C<br />
-40.000<br />
-60.000<br />
5°C<br />
Sauce A<br />
Sauce B<br />
> ><br />
Efficiently compare the stability<br />
profile of various formulations<br />
under stress or natural ageing<br />
-80.000<br />
-200.00 -100.00 0.00 100.00 200.00<br />
C1: 95.47 %<br />
Comparison of taste evolution of 2 sauces A<br />
and B after 30 days of storage at three various<br />
temperatures: 5°C, 25°C and 30°C.<br />
Sauce B is more stable than sauce A.<br />
T aste Comparison<br />
Compare various products:<br />
S new and original formulations<br />
S yours and competitors<br />
S brand products & generics<br />
S products from various origins …<br />
C2: 10.58 %<br />
60.000<br />
40.000<br />
20.000<br />
0.000<br />
-20.000<br />
-40.000<br />
Best formulation<br />
candidate<br />
Discrimination index: 95<br />
Competitor 2<br />
best<br />
> ><br />
Benchmark your competitors<br />
Monitor quality of your suppliers<br />
Compare your processes<br />
-60.000<br />
-80.000<br />
Competitor 1<br />
Competitor 3<br />
-100.000<br />
-200.00 -100.00 0.00 100.00 200.00<br />
C1: 80.76 %<br />
After comparing 3 marketed products, the<br />
formulation candidate selected will be the one<br />
closer to the more palatable competitive product.
What can the<br />
<strong>Electronic</strong> <strong>Tongue</strong><br />
do for you?<br />
• Develop products with consumer oriented taste<br />
• Avoid consumer complains & re-development process<br />
• Multiply taste screening & test more formulation candidates<br />
• Build internal organoleptic expertise<br />
• Save time and money by speeding up product development<br />
Food & Beverages<br />
S Mineral water<br />
S Soda - fruit & vegetable juice<br />
S Coffee - tea - chocolate<br />
S Dairy products & milk<br />
S Beer - wine - liquor<br />
S Freezed dried soup - tomato sauce<br />
S Salad dressing - vinegar …<br />
Nutraceuticals<br />
& Pharmaceuticals<br />
S Tablets (coated, effervescent and dispersible …)<br />
S Lozenges<br />
S Microgranules<br />
S Powder<br />
S Hard or Soft capsules<br />
S Oral liquid solutions & syrups …<br />
Saltiness, Sweetness, Sourness, Bitterness, Umami<br />
Pungency, Spiciness, Astringency, Kukomi ...<br />
S Taste masking efficiency<br />
S Discrimination of origins<br />
S Product stability testing<br />
S Packaging migration monitoring<br />
S Taste matching of gold reference<br />
S Comparison with other products<br />
S Bitterness masking efficiency<br />
S Shelf life & ageing<br />
S Placebo taste matching<br />
S Quantification of additives & drugs<br />
S Comparison with competitive products<br />
Test products<br />
- even non GRAS*<br />
*Generally Recognized As Safe<br />
21 CFR Part 11 Compliant<br />
Analyze the flavor and taste of:<br />
• raw materials<br />
• standard or new formulations<br />
• pilot, intermediate and final products
<strong>Electronic</strong> <strong>Tongue</strong><br />
Working principle<br />
Like the human tongue, the <strong>ASTREE</strong> <strong>Electronic</strong> <strong>Tongue</strong><br />
performs a global analysis (fingerprint) of a complex dissolved<br />
organic or inorganic compounds mixture.<br />
The sensor head (7 cross selective sensors) dips into the liquid<br />
sample to be tested.<br />
Manipulation are automatically executed thanks to the<br />
autosampler. Record of the sensor output is performed within<br />
2 minutes and then analyzed by a complete chemometric<br />
software using multivariate statistics.<br />
><br />
Taste receptor<br />
Acquisition<br />
Sensors<br />
Brain analysis<br />
><br />
Data treatment<br />
><br />
Software analysis<br />
Fingerprint Recognition<br />
Comparison<br />
Statistical Analysis<br />
Fingerprint Recognition<br />
<strong>ASTREE</strong> <strong>Electronic</strong> <strong>Tongue</strong> has for all basic tastes a similar<br />
or better detection threshold than the Human <strong>Tongue</strong>.<br />
M ore results<br />
Caffein level prediction in coffees Discrimination of tea (origin & steeping time) Beer freshness discrimination<br />
<strong>ASTREE</strong> Values<br />
5.00<br />
4.50<br />
4.00<br />
3.50<br />
3.00<br />
2.50<br />
2.00<br />
1.50<br />
1.00<br />
0.50<br />
0.00<br />
C1<br />
C3<br />
C2<br />
Caffein 0%<br />
Caffein 1%<br />
C4<br />
-0.50<br />
0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00<br />
After building a predictive model (black spots),<br />
<strong>ASTREE</strong> can determine caffein concentration<br />
in various coffees (C1 to C6) with a very good<br />
reproducibility.<br />
Correlation: 0.993780 C1: 6,51 % Discrimination index: 96 Residual Error Percentage of recognition: 100<br />
Caffein 2%<br />
S Liquid Autosampler with a carroussel<br />
capacity: 16 beakers (80 mL) or 48 beakers (20<br />
mL), a programmable sample agitation, a robotic<br />
sensor head and individual connections for<br />
each sensor<br />
S Astree Electrochemical Sensor Array <br />
including one reference electrode (Ag/AgCl)<br />
and 7 liquid cross selective sensors with 2 specific<br />
sets (Food & Beverage or Pharmaceutical<br />
industries).<br />
S Astree <strong>Electronic</strong> <strong>Tongue</strong> Unit with sensor<br />
board (1 to 28 channels available), acquisition board<br />
(acquisition frequency 10 Hz), main board for data<br />
acquisition and power supply card (110-120 VAC,<br />
220-240 VAC)<br />
• External Input / output: RS232 connections<br />
• <strong>Electronic</strong> Unit Dimensions (L x W x H):<br />
26 x 30 x 100 cm - 66 x 76 x 254 inch<br />
• <strong>Electronic</strong> Unit Weight: 25 kg<br />
C5<br />
Caffein 3%<br />
C6<br />
Caffein 4%<br />
Real Values (% of caffein)<br />
Caffein 5%<br />
100.000<br />
90.000<br />
80.000<br />
70.000<br />
60.000<br />
50.000<br />
40.000<br />
30.000<br />
20.000<br />
10.000<br />
0.000<br />
-10.000<br />
-20.000<br />
-30.000<br />
-40.000<br />
-50.000<br />
-60.000<br />
Steeping time<br />
Yunnan<br />
Plantation d'Or<br />
Ceylan<br />
Origin<br />
Wu Long<br />
-160.00 -140.00 -120.00 -100.00 -80.00 -60.00 -40.00 -20.00 0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00 200.00 220.00<br />
■ Yunnan (Black tea from China)<br />
■ Plantation d'Or (Black tea from China)<br />
■ Ceylan (Black tea from Sri Lanka)<br />
■ Wu Long (Tea from Taiwan)<br />
■ Sencha (Green tea from Japan)<br />
Sencha<br />
S Astree Software V3.0 with autosampler<br />
and acquisition control, a complete multivariate<br />
statistics package (PCA, DFA, SIMCA, PLS)<br />
and various maintenance tools as automatic<br />
system diagnostic & sensor diagnostic<br />
S Consumable Packages included: start-up<br />
kit (beakers, diagnostic solutions), calibration<br />
solutions, complete maintenance kit (electrolyte,<br />
rinsing & diagnostic solutions, spare sensor<br />
set), accessory kit<br />
C2: 93.20 %<br />
3 steeping times<br />
- 4 minutes<br />
- 6 minutes<br />
- 8 minutes<br />
1.OE+3<br />
1.OE+2<br />
1.OE+1<br />
1.OE+0<br />
1.OE-1<br />
1.OE-2<br />
1.OE-3<br />
Conformity<br />
Area<br />
M ain system specifications<br />
Multi-language software<br />
<br />
Out specification<br />
products<br />
1.OE-4<br />
1.OE+0 1.OE+1 1.OE+2 1.OE+3 1.OE+4<br />
Distances<br />
After a training phase, the <strong>ASTREE</strong> is able to<br />
discriminate fresh beers from aged beers<br />
(from 3 to 5 months).<br />
<br />
<br />
<br />
S Analysis features:<br />
• Environmental Conditions:<br />
operating temperature constant +/ 3°C<br />
• Analysis Time 200s including:<br />
- Sensor acquisition: 120s<br />
- Rinsing time: 10s<br />
• Precision: RSD ≤ 3%<br />
• Sensibility and Accuracy: sensors sensitive<br />
and partially selective to chemical species<br />
- ionic and neutral.<br />
Alpha M.O.S Headquarters<br />
20, Av Didier Daurat 31400 Toulouse - France<br />
Ph: + 33 5 62475380 / Fax: + 33 5 61545615<br />
E-mail: info@alpha-mos.com<br />
Alpha M.O.S. America<br />
33 North River St. Hillsborough, NJ 08844<br />
Ph: 908.359.9396 / Fax: 908.359.9398<br />
E-mail: amusa@alpha-mos.com<br />
Visit our website: www.alpha-mos.com