01.05.2015 Views

ASTREE Electronic Tongue

ASTREE Electronic Tongue

ASTREE Electronic Tongue

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Cutting edge technology for taste development of formulation!<br />

<strong>ASTREE</strong><br />

><br />

<strong>Electronic</strong> <strong>Tongue</strong><br />

Objective & Safe Taste Measurement - Fingerprint Liquid Analyzer<br />

> Food & Beverage<br />

> Nutraceutical & Pharmaceutical<br />

> Tobacco


T aste Masking<br />

> ><br />

<strong>ASTREE</strong><br />

the key tool for taste assessment<br />

><br />

S Optimize the taste masking efficiency of active<br />

(NCE / Nutraceutical) formulation even before<br />

safety assessment study<br />

S Assess the impact on taste of every ingredient<br />

S Measure the bitterness intensity and improve<br />

your formulation design / selection<br />

S Enlarge your portfolio of choice of ingredients<br />

without a systematic use of sensory panel<br />

Improve your formulation<br />

for better consumer likings<br />

C2: 24.69 %<br />

400<br />

300<br />

200<br />

100<br />

P4<br />

0<br />

Good<br />

Masking<br />

F4<br />

P3<br />

P1<br />

P2<br />

F3<br />

Discrimination index: 90<br />

Increase and change<br />

of masking agent<br />

in placebo formulation<br />

Increase and<br />

change of<br />

masking agent<br />

in active formulation<br />

-100 0 500 1000 1500<br />

C1: 70.94 %<br />

Comparison of formulation with active drug (F)<br />

and the corresponding formulation without<br />

active substance (placebo P). When the distance<br />

is reduced, the taste masking has been improved.<br />

F2<br />

F1<br />

S helf Life<br />

S Analyze taste evolution and stability of oral<br />

formulations according to various storage conditions,<br />

time or packaging<br />

C2: 3.57 %<br />

60.000<br />

40.000<br />

20.000<br />

0.000<br />

-20.000<br />

30°C<br />

25°C<br />

Discrimination index: 93<br />

Temperature<br />

increase<br />

25°C<br />

30°C<br />

5°C<br />

-40.000<br />

-60.000<br />

5°C<br />

Sauce A<br />

Sauce B<br />

> ><br />

Efficiently compare the stability<br />

profile of various formulations<br />

under stress or natural ageing<br />

-80.000<br />

-200.00 -100.00 0.00 100.00 200.00<br />

C1: 95.47 %<br />

Comparison of taste evolution of 2 sauces A<br />

and B after 30 days of storage at three various<br />

temperatures: 5°C, 25°C and 30°C.<br />

Sauce B is more stable than sauce A.<br />

T aste Comparison<br />

Compare various products:<br />

S new and original formulations<br />

S yours and competitors<br />

S brand products & generics<br />

S products from various origins …<br />

C2: 10.58 %<br />

60.000<br />

40.000<br />

20.000<br />

0.000<br />

-20.000<br />

-40.000<br />

Best formulation<br />

candidate<br />

Discrimination index: 95<br />

Competitor 2<br />

best<br />

> ><br />

Benchmark your competitors<br />

Monitor quality of your suppliers<br />

Compare your processes<br />

-60.000<br />

-80.000<br />

Competitor 1<br />

Competitor 3<br />

-100.000<br />

-200.00 -100.00 0.00 100.00 200.00<br />

C1: 80.76 %<br />

After comparing 3 marketed products, the<br />

formulation candidate selected will be the one<br />

closer to the more palatable competitive product.


What can the<br />

<strong>Electronic</strong> <strong>Tongue</strong><br />

do for you?<br />

• Develop products with consumer oriented taste<br />

• Avoid consumer complains & re-development process<br />

• Multiply taste screening & test more formulation candidates<br />

• Build internal organoleptic expertise<br />

• Save time and money by speeding up product development<br />

Food & Beverages<br />

S Mineral water<br />

S Soda - fruit & vegetable juice<br />

S Coffee - tea - chocolate<br />

S Dairy products & milk<br />

S Beer - wine - liquor<br />

S Freezed dried soup - tomato sauce<br />

S Salad dressing - vinegar …<br />

Nutraceuticals<br />

& Pharmaceuticals<br />

S Tablets (coated, effervescent and dispersible …)<br />

S Lozenges<br />

S Microgranules<br />

S Powder<br />

S Hard or Soft capsules<br />

S Oral liquid solutions & syrups …<br />

Saltiness, Sweetness, Sourness, Bitterness, Umami<br />

Pungency, Spiciness, Astringency, Kukomi ...<br />

S Taste masking efficiency<br />

S Discrimination of origins<br />

S Product stability testing<br />

S Packaging migration monitoring<br />

S Taste matching of gold reference<br />

S Comparison with other products<br />

S Bitterness masking efficiency<br />

S Shelf life & ageing<br />

S Placebo taste matching<br />

S Quantification of additives & drugs<br />

S Comparison with competitive products<br />

Test products<br />

- even non GRAS*<br />

*Generally Recognized As Safe<br />

21 CFR Part 11 Compliant<br />

Analyze the flavor and taste of:<br />

• raw materials<br />

• standard or new formulations<br />

• pilot, intermediate and final products


<strong>Electronic</strong> <strong>Tongue</strong><br />

Working principle<br />

Like the human tongue, the <strong>ASTREE</strong> <strong>Electronic</strong> <strong>Tongue</strong><br />

performs a global analysis (fingerprint) of a complex dissolved<br />

organic or inorganic compounds mixture.<br />

The sensor head (7 cross selective sensors) dips into the liquid<br />

sample to be tested.<br />

Manipulation are automatically executed thanks to the<br />

autosampler. Record of the sensor output is performed within<br />

2 minutes and then analyzed by a complete chemometric<br />

software using multivariate statistics.<br />

><br />

Taste receptor<br />

Acquisition<br />

Sensors<br />

Brain analysis<br />

><br />

Data treatment<br />

><br />

Software analysis<br />

Fingerprint Recognition<br />

Comparison<br />

Statistical Analysis<br />

Fingerprint Recognition<br />

<strong>ASTREE</strong> <strong>Electronic</strong> <strong>Tongue</strong> has for all basic tastes a similar<br />

or better detection threshold than the Human <strong>Tongue</strong>.<br />

M ore results<br />

Caffein level prediction in coffees Discrimination of tea (origin & steeping time) Beer freshness discrimination<br />

<strong>ASTREE</strong> Values<br />

5.00<br />

4.50<br />

4.00<br />

3.50<br />

3.00<br />

2.50<br />

2.00<br />

1.50<br />

1.00<br />

0.50<br />

0.00<br />

C1<br />

C3<br />

C2<br />

Caffein 0%<br />

Caffein 1%<br />

C4<br />

-0.50<br />

0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00<br />

After building a predictive model (black spots),<br />

<strong>ASTREE</strong> can determine caffein concentration<br />

in various coffees (C1 to C6) with a very good<br />

reproducibility.<br />

Correlation: 0.993780 C1: 6,51 % Discrimination index: 96 Residual Error Percentage of recognition: 100<br />

Caffein 2%<br />

S Liquid Autosampler with a carroussel<br />

capacity: 16 beakers (80 mL) or 48 beakers (20<br />

mL), a programmable sample agitation, a robotic<br />

sensor head and individual connections for<br />

each sensor<br />

S Astree Electrochemical Sensor Array <br />

including one reference electrode (Ag/AgCl)<br />

and 7 liquid cross selective sensors with 2 specific<br />

sets (Food & Beverage or Pharmaceutical<br />

industries).<br />

S Astree <strong>Electronic</strong> <strong>Tongue</strong> Unit with sensor<br />

board (1 to 28 channels available), acquisition board<br />

(acquisition frequency 10 Hz), main board for data<br />

acquisition and power supply card (110-120 VAC,<br />

220-240 VAC)<br />

• External Input / output: RS232 connections<br />

• <strong>Electronic</strong> Unit Dimensions (L x W x H):<br />

26 x 30 x 100 cm - 66 x 76 x 254 inch<br />

• <strong>Electronic</strong> Unit Weight: 25 kg<br />

C5<br />

Caffein 3%<br />

C6<br />

Caffein 4%<br />

Real Values (% of caffein)<br />

Caffein 5%<br />

100.000<br />

90.000<br />

80.000<br />

70.000<br />

60.000<br />

50.000<br />

40.000<br />

30.000<br />

20.000<br />

10.000<br />

0.000<br />

-10.000<br />

-20.000<br />

-30.000<br />

-40.000<br />

-50.000<br />

-60.000<br />

Steeping time<br />

Yunnan<br />

Plantation d'Or<br />

Ceylan<br />

Origin<br />

Wu Long<br />

-160.00 -140.00 -120.00 -100.00 -80.00 -60.00 -40.00 -20.00 0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00 200.00 220.00<br />

■ Yunnan (Black tea from China)<br />

■ Plantation d'Or (Black tea from China)<br />

■ Ceylan (Black tea from Sri Lanka)<br />

■ Wu Long (Tea from Taiwan)<br />

■ Sencha (Green tea from Japan)<br />

Sencha<br />

S Astree Software V3.0 with autosampler<br />

and acquisition control, a complete multivariate<br />

statistics package (PCA, DFA, SIMCA, PLS)<br />

and various maintenance tools as automatic<br />

system diagnostic & sensor diagnostic<br />

S Consumable Packages included: start-up<br />

kit (beakers, diagnostic solutions), calibration<br />

solutions, complete maintenance kit (electrolyte,<br />

rinsing & diagnostic solutions, spare sensor<br />

set), accessory kit<br />

C2: 93.20 %<br />

3 steeping times<br />

- 4 minutes<br />

- 6 minutes<br />

- 8 minutes<br />

1.OE+3<br />

1.OE+2<br />

1.OE+1<br />

1.OE+0<br />

1.OE-1<br />

1.OE-2<br />

1.OE-3<br />

Conformity<br />

Area<br />

M ain system specifications<br />

Multi-language software<br />

<br />

Out specification<br />

products<br />

1.OE-4<br />

1.OE+0 1.OE+1 1.OE+2 1.OE+3 1.OE+4<br />

Distances<br />

After a training phase, the <strong>ASTREE</strong> is able to<br />

discriminate fresh beers from aged beers<br />

(from 3 to 5 months).<br />

<br />

<br />

<br />

S Analysis features:<br />

• Environmental Conditions:<br />

operating temperature constant +/ 3°C<br />

• Analysis Time 200s including:<br />

- Sensor acquisition: 120s<br />

- Rinsing time: 10s<br />

• Precision: RSD ≤ 3%<br />

• Sensibility and Accuracy: sensors sensitive<br />

and partially selective to chemical species<br />

- ionic and neutral.<br />

Alpha M.O.S Headquarters<br />

20, Av Didier Daurat 31400 Toulouse - France<br />

Ph: + 33 5 62475380 / Fax: + 33 5 61545615<br />

E-mail: info@alpha-mos.com<br />

Alpha M.O.S. America<br />

33 North River St. Hillsborough, NJ 08844<br />

Ph: 908.359.9396 / Fax: 908.359.9398<br />

E-mail: amusa@alpha-mos.com<br />

Visit our website: www.alpha-mos.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!