01.05.2015 Views

Rittal - IT News 2009 - Rittal GmbH & Co. KG

Rittal - IT News 2009 - Rittal GmbH & Co. KG

Rittal - IT News 2009 - Rittal GmbH & Co. KG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Rittal</strong> – <strong>IT</strong> <strong>News</strong> <strong>2009</strong><br />

Up to 50%<br />

more efficient<br />

<strong>Co</strong>mplete <strong>IT</strong> competence –<br />

faster, more efficient, worldwide


Get more out of your investment<br />

As energy costs rise, cost optimisation of <strong>IT</strong> systems<br />

is a top priority, alongside security. The name <strong>Rittal</strong><br />

is synonymous with holistic solutions and maximum<br />

exploitation of all synergy potential. Efficiency reserves<br />

and optimisation potential may be found everywhere,<br />

leading to more cost-effective <strong>IT</strong> security and permanent<br />

<strong>IT</strong> availability. This more efficient handling of<br />

energy resources releases monetary potential within<br />

the company. You save energy and hard cash which<br />

can be invested in your company, however large or<br />

small it is.<br />

With <strong>Rittal</strong> at your side, you get efficiency times four:<br />

Efficiency with energy, security, availability and<br />

synergy.<br />

With the powerful alliance<br />

R R<br />

<strong>Rittal</strong> – <strong>Co</strong>mplete <strong>IT</strong> <strong>Co</strong>mpetence<br />

CONTENTS<br />

Networking, server racks from page 8<br />

Power from page 18<br />

<strong>Co</strong>oling from page 26<br />

Security, monitoring from page 34<br />

Save up to 50%<br />

<strong>Co</strong>mmunication Systems from page 48<br />

Accessories from page 49<br />

Security rooms from page 58<br />

2 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>


10% power distribution<br />

and backup<br />

3% light, etc.<br />

50% servers<br />

Excess capacity<br />

without RimatriX5<br />

Scalable<br />

capacity adjustment<br />

with RimatriX5<br />

Efficiency<br />

CO 2 emissions<br />

<strong>Co</strong>st €<br />

37% cooling Current<br />

power requirements<br />

Boosting efficiency is a matter of determination,<br />

not size. Regardless of whether<br />

you want to optimise a single rack,<br />

a complex data centre or the whole<br />

company, the buzzword is always the<br />

same: efficiency.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong><br />

You just need to take a closer look. Savings of up<br />

to 50% can be made with the operating costs for<br />

cooling and UPS. And there’s no need to forego<br />

anything. On the contrary – you will create a financial<br />

cushion for new investments.<br />

Even Darwin realised that only those “systems”<br />

which adapt to the environment will<br />

survive. RimatriX5 is synonymous with<br />

optimum adaptation to the requirements<br />

demanded by your <strong>IT</strong> environment.<br />

3


Boost your efficiency<br />

With this in mind, <strong>Rittal</strong>’s philosophy is to address<br />

a whole range of issues, not just one. By utilising<br />

the available potential across all sectors, electricity<br />

savings can be achieved with power distribution and<br />

redundancy in UPS systems. It is only possible to<br />

reduce operating costs on this scale with systems that<br />

are tailored to the very latest computer technology.<br />

However, the effort undoubtedly pays off. Increasing<br />

the efficiency of a UPS by just 2% can cut heat loss<br />

costs by up to 30%.<br />

97<br />

96<br />

95.5<br />

96<br />

Efficiency (%)<br />

95<br />

94<br />

93<br />

94<br />

95<br />

–30% heat loss<br />

92<br />

91<br />

90<br />

25 50 75 100<br />

UPS capacity utilisation (%)<br />

4 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>


Haven’t you always wanted to know<br />

which pieces of equipment are the<br />

biggest power consumers? The Power<br />

System Module PSM will show you –<br />

in exact detail.<br />

Precisely targeted down to individual<br />

item level. The whole thing is conveniently<br />

trackable online – thanks to<br />

networking capabilities in conjunction<br />

with the CMC-TC system.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong><br />

5


Finger on the pulse<br />

RiZone means complete control over the physical<br />

<strong>IT</strong> infrastructure.<br />

In RiZone, there is an intelligent interplay between<br />

intended results and cost-effectiveness. With RiZone,<br />

<strong>Rittal</strong> offers an innovative software package for the<br />

integral monitoring and administration of <strong>IT</strong> infrastructures<br />

and servers. In short, RiZone is the new<br />

efficiency software in the data centre. Modular and<br />

scalable, from small companies to large data centres,<br />

and always with maximum effect. Integration into the<br />

System Center Operations Manager (SCOM) from<br />

Microsoft turns RiZone into a highlight, ensuring that<br />

the <strong>IT</strong> team has all processes in the data centre firmly<br />

under control.<br />

+<br />

+<br />

+<br />

+<br />

=<br />

Huge electricity savings<br />

Easy project planning<br />

Enhanced protection<br />

Tailored systems<br />

RiZone cost-efficiency<br />

6 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>


Efficiency example: cooling<br />

Sub-optimum cooling output<br />

Optimum cooling output<br />

Heat load (<strong>IT</strong> load)<br />

kW<br />

MON TUE WED THU FRI SAT SUN<br />

Assume the servers in your data centre<br />

have a maximum power consumption of<br />

X kW. <strong>Co</strong>rrespondingly, the cooling output<br />

must be designed for this maximum output<br />

in unfavourable ambient temperatures.<br />

As this diagram of weekly operation shows,<br />

unless properly managed, a typical cooling<br />

system is overdimensioned most of the<br />

time.<br />

Here, RiZone saves energy by intelligently<br />

adapting the cooling output to the power<br />

consumption, airflow and ambient temperature.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong><br />

7


19 /535<br />

Networking<br />

TE 7000 open<br />

T<br />

B<br />

B<br />

T<br />

HE/SU<br />

HE<br />

H<br />

H<br />

19<br />

HE = U<br />

Benefits:<br />

Unlimited applications covering<br />

all tasks in the <strong>IT</strong> sector. Both as<br />

a network distribution frame with<br />

maximum accessibility from all<br />

sides for assembly and installation,<br />

and as a server rack with<br />

a high load capacity of up to<br />

700 kg, static. Unrestricted airflow,<br />

due to the open design.<br />

The standard cable trays in the<br />

roof area mean that even large<br />

quantities of cables are easily<br />

routed to the various levels without<br />

kinks.<br />

In a bayed configuration, the<br />

800 mm width in particular offers<br />

plenty of space for cable routing<br />

between units.<br />

There is an extensive range of<br />

accessories available for individual<br />

cable management solutions.<br />

The distance between attachment<br />

levels is infinitely variable.<br />

Material:<br />

Sheet steel<br />

Surface finish:<br />

Powder-coated, RAL 7035<br />

Load capacity:<br />

700 kg, static<br />

Supply includes:<br />

Self-supporting frame structure,<br />

with a 482.6 mm (19˝) or metric<br />

attachment level front and rear<br />

depending on the design.<br />

Open roof frame for cable entry,<br />

via 3 (1 for DK 7000.930/.934)<br />

cable routing trays. Open base<br />

frame with 2 punched sections<br />

with mounting flanges for individual<br />

configuration fitted in the<br />

width, levelling feet.<br />

Detailed drawing,<br />

available on the Internet.<br />

NEW<br />

NEW<br />

U/SU 42/– 42/– 42/76 47/82 42/– 47/–<br />

Width (B) mm 600 800 600 600 800 800<br />

Height 3) (H) mm 2000 2000 2000 2200 2000 2200<br />

Depth (T) mm 800 800 1000 1000 1000 1000<br />

Distance between levels (mm) as delivered 495 495 745 745 745 745<br />

Model No. TE with 482.6 mm (19˝) attachment level 7000.930 7000.934 7000.940 7000.942 1) 7000.944 7000.946 1)<br />

Model No. TE with metric (535 mm) attachment level – – 7000.960 1) 7000.962 1) – –<br />

482.6 mm (19˝) accessories Packs of<br />

Cable management panel 482.6 mm (19˝), 1 U for horizontal<br />

cable routing, with 5 steel rings, zinc-plated, passivated,<br />

1 7257.035 7257.035 7257.035 7257.035 7257.035 7257.035<br />

size 100 x 37 mm<br />

Cable management panel 482.6 mm (19˝), 2 U for horizontal<br />

cable routing, with 5 steel rings, zinc-plated, passivated,<br />

1 7257.100 7257.100 7257.100 7257.100 7257.100 7257.100<br />

size 120 x 80 mm<br />

Shunting rings to accommodate large quantities of cables,<br />

for mounting on the side of the mounting frame,<br />

2 7220.600 7220.600 7220.600 7220.600 7220.600 7220.600<br />

dimensions 300 x 90 mm<br />

Cable management panel 482.6 mm (19˝), 2 U, for horizontal<br />

cable routing, with removable front panel<br />

1 7158.100 7158.100 7158.100 7158.100 7158.100 7158.100<br />

<strong>Co</strong>mponent shelf 482.6 mm (19˝), 1 / 2 U static installation,<br />

depth-variable<br />

1 7063.710 2) 7063.710 2) 7063.720 2) 7063.720 2) 7063.720 7063.720<br />

Slide rail 482.6 mm (19˝), load capacity 100 kg, static,<br />

for distance between 482.6 mm (19˝) levels (internal) 740 mm<br />

2 – – 7063.740 2) 7063.740 2) 7063.740 7063.740<br />

Slide rail 482.6 mm (19˝),<br />

depth-variable within the range from 590 – 930 mm,<br />

2 7063.882 2) 7063.882 2) 7063.883 2) 7063.883 2) 7063.883 7063.883<br />

load capacity 80 kg, static<br />

C rail, variable within the range 450 – 850 mm 1 7016.140 7016.140 7016.140 7016.140 7016.140 7016.140<br />

T-head rail,<br />

variable within the range 450 – 850 mm<br />

1 7016.150 7016.150 7016.150 7016.150 7016.150 7016.150<br />

Cable route for vertical cable management,<br />

for mounting at the side rear of the 482.6 mm (19˝) mounting<br />

frame, W = 100 mm, H = 1700 mm<br />

1 set 7000.685 7000.685 7000.685 7000.685 7000.685 7000.685<br />

1) Delivery times available on request.<br />

2)<br />

Not suitable for use with a metric attachment level.<br />

3) Plus 100 mm roof-mounting/cable-routing trays.<br />

8 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Networking


Networking<br />

Network enclosures, based on <strong>Rittal</strong> TS 8, pre-configured<br />

T1<br />

B1<br />

T1<br />

B1<br />

H2<br />

H2<br />

H1<br />

H3<br />

H1<br />

H3<br />

B2<br />

T2<br />

Material:<br />

Sheet steel<br />

Surface finish:<br />

Enclosure frame:<br />

Dipcoat-primed<br />

Doors, roof and base/plinth:<br />

Dipcoat-primed,<br />

powder-coated in RAL 7035<br />

Gland plates, punched sections<br />

with mounting flanges and<br />

mounting angles:<br />

Zinc-plated, passivated<br />

Supply includes:<br />

Enclosure frame with doors or<br />

rear panel, roof plate, vented<br />

base/plinth 100 mm,<br />

earthing of all enclosure panels;<br />

Supplied loose:<br />

Levelling feet incl. base/plinth<br />

adaptor,<br />

4 spacers, for raising the roof,<br />

4 cable clamp rails for the inner<br />

frame level,<br />

10 cable shunting rings<br />

(105 x 70 mm, plastic, for<br />

DK 7830.100 in 44 x 70 mm),<br />

50 captive nuts M6, conductive,<br />

50 multi-tooth screws M6.<br />

Version 1<br />

Glazed aluminium front door,<br />

180°, with comfort handle for<br />

semi-cylinder and security lock<br />

3524 E;<br />

sheet steel rear door, 130°,<br />

with swivel handle and security<br />

lock 3524 E.<br />

482.6 mm (19˝) mounting<br />

angles, front, fitted approx.<br />

150 mm behind the frame front<br />

edge,<br />

screw-fastened to the TS<br />

punched sections with mounting<br />

flange as depth stays.<br />

Gland plate, one-piece, vented,<br />

with cable entry.<br />

Version 2<br />

Glazed aluminium front door,<br />

180°, with comfort handle for<br />

semi-cylinder and security lock<br />

3524 E;<br />

sheet steel rear door, 130°,<br />

with swivel handle and security<br />

lock 3524 E.<br />

482.6 mm (19˝) mounting angles<br />

at the front and rear, distance<br />

between levels pre-configured<br />

at 498 mm. Cranked mounting<br />

angles screw-fastened to installation<br />

brackets approx. 150 mm<br />

behind the frame front edge.<br />

Gland plate at the front, fitted as<br />

an infill panel.<br />

Version 2 plus<br />

Extra system accessories supplied<br />

loose: <strong>Co</strong>mpact light (8 W),<br />

mounting kit (magnetic),<br />

482.6 mm (19˝) socket strip,<br />

(earthing-pin), door-operated<br />

switch, junction box incl.<br />

connection accessories,<br />

482.6 mm (19˝) component shelf<br />

(500 mm) incl. mounting accessories.<br />

Detailed drawing,<br />

available on the Internet.<br />

NEW<br />

Version 1 Version 2 Version 2 Version 2 Version 2 plus Version 2 Version 2<br />

NEW<br />

NEW<br />

U 24 24 38 42 42 42 47<br />

Width (B1) mm 1) 600 800 800 800 800 800 800<br />

Height (H1 + H2) mm 1) 1200 + 100 1200 + 100 1800 + 100 2000 + 100 2000 + 100 2000 + 100 2200 + 100<br />

Depth (T1) mm 1) 600 800 800 800 800 1000 800<br />

Clearance width (B2) mm 512 712 712 712 712 712 712<br />

Clearance height (H3) mm 1112 1112 1712 1912 1912 1912 2112<br />

Clearance depth (T2) mm 512 712 712 712 712 912 712<br />

Model No. DK<br />

including 2 plug-in side panels,<br />

with security lock 3524 E<br />

Model No. DK<br />

as bayed enclosure without side panels,<br />

including baying kit TS 8800.500<br />

7830.100 7830.110 7830.800 7830.200 7830.202 7830.230 7830.220<br />

– – 7830.850 2) 7830.250 – 7830.240 7830.270 2)<br />

1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />

2) Delivery times available on request.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Networking<br />

9


Networking<br />

Network enclosures, based on <strong>Rittal</strong> TS 8, pre-configured<br />

T1<br />

B1<br />

T1<br />

B1<br />

H2<br />

H2<br />

H1<br />

H3<br />

H1<br />

H3<br />

B2<br />

T2<br />

Material:<br />

Sheet steel<br />

Surface finish:<br />

Enclosure frame:<br />

Dipcoat-primed<br />

Doors, roof and base/plinth:<br />

Dipcoat-primed,<br />

powder-coated in RAL 7035<br />

Gland plates, punched sections<br />

with mounting flanges and<br />

mounting angles:<br />

Zinc-plated, passivated<br />

Supply includes:<br />

Enclosure frame with doors or<br />

rear panel, roof plate,<br />

vented base/plinth 100 mm,<br />

earthing of all enclosure panels;<br />

Supplied loose:<br />

Levelling feet incl. base/plinth<br />

adaptor,<br />

4 spacers for raising the roof,<br />

4 cable clamp rails for the inner<br />

frame level,<br />

10 cable shunting rings<br />

(105 x 70 mm, plastic)<br />

50 captive nuts M6, conductive,<br />

50 multi-tooth screws M6.<br />

Version 3<br />

Vented glazed front door, 180°,<br />

with comfort handle for semi-cylinder<br />

and security lock 3524 E;<br />

sheet steel rear door, 180°,<br />

with swivel handle and security<br />

lock 3524 E.<br />

482.6 mm (19˝) mounting angles<br />

at the front and rear, distance<br />

between levels pre-configured<br />

at 740 mm.<br />

L-shaped mounting angles<br />

screw-fastened to 2 or 3 depth<br />

stays respectively approx.<br />

80 mm behind the front edge<br />

of the frame.<br />

Gland plate, one-piece, vented,<br />

with cable entry.<br />

Detailed drawing,<br />

available on the Internet.<br />

NEW<br />

Version 3 Version 3 Version 3 Version 3 Version 3 Version 3<br />

U 24 24 42 42 47 47<br />

Width (B1) mm 1) 800 800 800 800 800 800<br />

Height (H1 + H2) mm 1) 1200 + 100 1200 + 100 2000 + 100 2000 + 100 2200 + 100 2200 + 100<br />

Depth (T1) mm 1) 900 1000 900 1000 900 1000<br />

Clearance width (B2) mm 712 712 712 712 712 712<br />

Clearance height (H3) mm 1112 1112 1912 1912 2112 2112<br />

Clearance depth (T2) mm 812 912 812 912 812 912<br />

Model No. DK<br />

including 2 plug-in side panels,<br />

with security lock 3524 E<br />

Model No. DK<br />

as bayed enclosure without side panels,<br />

including baying kit TS 8800.500<br />

7830.120 7830.130 7830.300 7830.330 7830.320 2) 7830.340 2)<br />

– – 7830.350 7830.335 7830.370 2) 7830.380 2)<br />

1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />

2) Delivery times available on request.<br />

10 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Networking


Networking<br />

Network enclosures, based on <strong>Rittal</strong> TS 8, types 1 and 2<br />

T1<br />

B1<br />

T1<br />

B1<br />

H2<br />

B2<br />

H1<br />

H1<br />

T2<br />

Type 1<br />

Glazed aluminium front door<br />

(180°),<br />

with 3 mm single-pane safety<br />

glass, comfort handle for<br />

semi-cylinder and security lock<br />

3524 E;<br />

sheet steel rear door (130°) with<br />

handle and security lock 3524 E.<br />

Side panels, screw-fastened<br />

(depending on version).<br />

Type 2<br />

Sheet steel front door (180°),<br />

with comfort handle for semi-cylinder<br />

and security lock 3524 E;<br />

sheet steel rear door (130°) with<br />

handle and security lock 3524 E.<br />

Side panels, screw-fastened<br />

(depending on version).<br />

Material:<br />

Sheet steel<br />

Surface finish:<br />

Enclosure frame:<br />

Dipcoat-primed<br />

Doors, side panels and roof:<br />

Dipcoat-primed, powder-coated<br />

in RAL 7035<br />

Gland plates and punched<br />

sections with mounting flanges:<br />

Zinc-plated, passivated<br />

Supply includes:<br />

Enclosure frame (side panels,<br />

depending on version) with<br />

doors, roof plate, multi-piece<br />

gland plate, 2 punched sections<br />

with mounting flanges in<br />

the enclosure depth.<br />

Approvals,<br />

see Cat. 32, page 92.<br />

Detailed drawing,<br />

available on the Internet.<br />

U 15 20 20 24 24 24 24 24 29<br />

Width (B1) mm 1) 600 600 800 600 800 800 800 800 600<br />

Height (H1) mm 1) 800 1000 1000 1200 1200 1200 1200 1200 1400<br />

Depth (T1) mm 1) 600 600 600 600 600 800 900 1000 600<br />

Clearance width (B2) mm 512 512 712 512 712 712 712 712 512<br />

Clearance height (H2) mm 712 912 912 1112 1112 1112 1112 1112 1312<br />

Clearance depth (T2) mm 512 512 512 512 512 712 812 912 512<br />

Model No. DK,<br />

type 1, with glazed aluminium front door<br />

Model No. DK,<br />

type 1, with glazed aluminium front door,<br />

incl. side panel, screw-fastened, IP 55<br />

Model No. DK,<br />

type 2, with sheet steel front door<br />

Model No. DK,<br />

type 2, with sheet steel front door,<br />

incl. side panel, screw-fastened, IP 55<br />

7820.100 7820.200 7820.240 2) 7820.300 7820.340 2) 7820.350 7820.355 7820.360 2) 7820.400 2)<br />

– – – – – – – – –<br />

7821.100 7821.200 7821.240 2) 7821.300 7821.340 – 7821.355 – 7821.400 2)<br />

– – – – – – – – –<br />

U 29 29 33 33 33 38 38 38 38<br />

Width (B1) mm 1) 600 800 600 600 800 600 600 600 800<br />

Height (H1) mm 1) 1400 1400 1600 1600 1600 1800 1800 1800 1800<br />

Depth (T1) mm 1) 800 600 600 800 600 600 800 900 600<br />

Clearance width (B2) mm 512 712 512 512 712 512 512 512 712<br />

Clearance height (H2) mm 1312 1312 1512 1512 1512 1512 1712 1712 1712<br />

Clearance depth (T2) mm 712 512 512 712 512 512 712 812 512<br />

Model No. DK,<br />

type 1, with glazed aluminium front door<br />

7820.410 7820.440 2) 7820.500 7820.510 7820.540 2) 7820.600 7820.610 7820.620 7820.640<br />

Model No. DK,<br />

type 1, with glazed aluminium front door, – – – – – – – – –<br />

incl. side panel, screw-fastened, IP 55<br />

Model No. DK,<br />

type 2, with sheet steel front door<br />

7821.410 7821.440 2) 7821.500 7821.510 7821.540 2) 7821.600 7821.610 7821.620 2) 7821.640 2)<br />

Model No. DK,<br />

type 2, with sheet steel front door,<br />

– – – – – – – – –<br />

incl. side panel, screw-fastened, IP 55<br />

1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet. 2) Delivery times available on request.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Networking<br />

11


Networking<br />

Network enclosures, based on <strong>Rittal</strong> TS 8, types 1 and 2<br />

T1<br />

B1<br />

T1<br />

B1<br />

H2<br />

B2<br />

H1<br />

H1<br />

T2<br />

Type 1<br />

Glazed aluminium front door<br />

(180°),<br />

with 3 mm single-pane safety<br />

glass, comfort handle for<br />

semi-cylinder and security lock<br />

3524 E;<br />

sheet steel rear door (130°) with<br />

handle and security lock 3524 E.<br />

Side panels, screw-fastened<br />

(depending on version).<br />

Type 2<br />

Sheet steel front door (180°),<br />

with comfort handle for semi-cylinder<br />

and security lock 3524 E;<br />

sheet steel rear door (130°) with<br />

handle and security lock 3524 E.<br />

Side panels, screw-fastened<br />

(depending on version).<br />

Material:<br />

Sheet steel<br />

Surface finish:<br />

Enclosure frame:<br />

Dipcoat-primed<br />

Doors, side panels and roof:<br />

Dipcoat-primed, powder-coated<br />

in RAL 7035<br />

Gland plates and punched<br />

sections with mounting flanges:<br />

Zinc-plated, passivated<br />

Supply includes:<br />

Enclosure frame (side panels,<br />

depending on version) with<br />

doors,<br />

roof plate, multi-piece gland<br />

plate, 2 punched sections<br />

with mounting flanges in the<br />

enclosure depth.<br />

Approvals,<br />

see Cat. 32, page 92.<br />

Detailed drawing,<br />

available on the Internet.<br />

U 38 38 42 42 42 42 42 42 42 42<br />

Width (B1) mm 1) 800 800 600 600 600 600 600 800 800 800<br />

Height (H1) mm 1) 1800 1800 2000 2000 2000 2000 2000 2000 2000 2000<br />

Depth (T1) mm 1) 800 1000 600 800 900 1000 1200 600 800 900<br />

Clearance width (B2) mm 712 712 512 512 512 512 512 512 712 712<br />

Clearance height (H2) mm 1712 1712 1912 1912 1912 1912 1912 1912 1912 1912<br />

Clearance depth (T2) mm 712 912 512 712 812 912 1112 512 712 812<br />

Model No. DK,<br />

type 1, with glazed aluminium front<br />

door<br />

Model No. DK,<br />

type 1, with glazed aluminium front<br />

door, incl. side panel, screw-fastened,<br />

IP 55<br />

Model No. DK,<br />

type 2, with sheet steel front door<br />

Model No. DK,<br />

type 2, with sheet steel front door,<br />

incl. side panel, screw-fastened, IP 55<br />

7820.650 7820.670 7820.700 7820.710 2) 7820.720 7820.730 7820.830 2) 7820.740 7820.750 7820.760<br />

– – – – – – 7820.832 2) – – –<br />

7821.650 7821.670 2) 7821.700 7821.710 2) 7821.720 7821.730 7821.830 2) 7821.740 7821.750 7821.760<br />

– – – – – – 7821.832 2) – – –<br />

NEW<br />

U 42 42 47 47 47 47 47 47 47 47<br />

Width (B1) mm 1) 800 800 600 600 600 800 800 800 800 800<br />

Height (H1) mm 1) 2000 2000 2200 2200 2200 2200 2200 2200 2200 2200<br />

Depth (T1) mm 1) 1000 1200 600 800 1200 600 800 900 1000 1200<br />

Clearance width (B2) mm 712 712 512 512 512 512 712 712 712 712<br />

Clearance height (H2) mm 1912 1912 2112 2112 2112 2112 2112 2112 2112 2112<br />

Clearance depth (T2) mm 912 1112 512 712 1112 512 712 812 912 1112<br />

Model No. DK,<br />

type 1, with glazed aluminium front 7820.770 7820.890 2) 7820.800 7820.810 7820.880 2) 7820.840 7820.850 7820.860 7820.870 7820.950 2)<br />

door<br />

Model No. DK,<br />

type 1, with glazed aluminium front<br />

door, incl. side panel, screw-fastened,<br />

– 7820.892 2) – – 7820.882 2) – – – – 7820.952 2)<br />

IP 55<br />

Model No. DK,<br />

type 2, with sheet steel front door<br />

7821.770 7821.890 2) 7821.800 7821.810 7821.880 2) 7821.840 2) 7821.850 7821.860 2) 7821.870 7821.950 2)<br />

Model No. DK,<br />

type 2, with sheet steel front door,<br />

– 7821.892 2) – – 7821.882 2) – – – – 7821.952 2)<br />

incl. side panel, screw-fastened, IP 55<br />

1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />

2) Delivery times available on request.<br />

NEW<br />

NEW<br />

NEW<br />

12 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Networking


Networking<br />

VerticalBox<br />

B<br />

T<br />

H<br />

<strong>Co</strong>mpact 482.6 mm (19˝)<br />

enclosure for small networks<br />

Minimal space requirements with<br />

optimum utilisation of the available<br />

space. May be used as a<br />

wall-mounted, under-desk or<br />

desktop enclosure, depending<br />

on requirements.<br />

482.6 mm (19˝) level at the front<br />

and rear, freely selectable door<br />

hinge.<br />

Quickly and easily removable<br />

door, rear panel and side panel<br />

allow free access to the interior<br />

installation.<br />

Passive ventilation in the roof<br />

and floor area.<br />

Rear panel prepared to accommodate<br />

an active fan.<br />

Cable entry optionally via the<br />

roof, base or rear panel.<br />

Material:<br />

Sheet steel,<br />

viewing window toughened<br />

safety glass, 3 mm<br />

<strong>Co</strong>lour:<br />

RAL 7035<br />

Supply includes:<br />

482.6 mm (19˝) enclosure, 5 U,<br />

with a mounting level front and<br />

rear.<br />

Glazed front door, one side<br />

panel fixed, one plug-in,<br />

removable, plug-in rear panel,<br />

removable, with opening for<br />

cable entry, prepared to accommodate<br />

one fan unit. Glazed<br />

door, side panel and rear panel<br />

with security lock 12321.<br />

Roof and base with vent slots<br />

and knock-outs for cable entry.<br />

4 plastic feet, self-adhesive,<br />

supplied loose.<br />

U Packs of 5 Page<br />

Width (B) mm 300<br />

Height (H) mm 550<br />

Depth (T) mm 600<br />

Model No. DK 1 7501.000<br />

Accessories<br />

Wall mounting bracket, 10 mm 4 2508.010 <strong>IT</strong> Cat. page 294<br />

Wall mounting bracket, 40 mm 4 2503.010 <strong>IT</strong> Cat. page 294<br />

Fan expansion kit, 230 V AC, 50/60 Hz, 117/135 m 3 /h, air throughput, unimpeded airflow 1 set 7980.100 <strong>IT</strong> Cat. page 127<br />

Blanking panel, 482.6 mm (19˝), 1 U, RAL 7035 2 7151.035 <strong>IT</strong> Cat. page 392<br />

Cable management panel, 482.6 mm (19˝), 1 U, RAL 7035, with 5 cable shunting rings<br />

40 x 50 mm<br />

1 7257.200<br />

Innovations 08,<br />

page 93<br />

482.6 mm (19˝) socket strip, 7-way, with rocker switch 1 7240.220 <strong>IT</strong> Cat. page 328<br />

Mounting kit for VerticalBox, 350 x 484 mm 1 7501.100 57<br />

482.6 mm (19˝) mounting angles, 12 U (10 U usable) 1) 2 7502.203 57<br />

Brush strip for cut-out openings 2 x 1 m 7072.200 <strong>IT</strong> Cat. page 347<br />

1)<br />

For mounting at the side of the VerticalBox. With these mounting angles, instead of 5 U vertically at the side, up to 10 U may be used horizontally<br />

if only a minimal installation depth is required. Infinitely depth-variable positioning.<br />

VerticalBox<br />

as instrument case<br />

VerticalBox<br />

as wall-mounted enclosure<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Networking<br />

13


Server racks<br />

Based on <strong>Rittal</strong> TE 7000, 1000 mm deep<br />

B<br />

T<br />

H<br />

HE<br />

19˝<br />

A<br />

A = Defined mounting<br />

distance for accessories,<br />

see below.<br />

Benefits:<br />

No frame structure,<br />

optimum accessibility<br />

Static load capacity:<br />

700 kg<br />

Material:<br />

Sheet steel<br />

Surface finish:<br />

Mounting frame:<br />

Dipcoat-primed<br />

Enclosure panels:<br />

Powder-coated, RAL 7035/9005<br />

Supply includes:<br />

Self-supporting 482.6 mm (19˝)<br />

frame structure,<br />

side panels (depending on version),<br />

vented sheet steel door<br />

front and rear, two-point locking<br />

rod, recessed handle (front) and<br />

security lock 3524 E,<br />

roof plate with brush strip<br />

for cable entry and concealed<br />

cut-out for fan integration,<br />

levelling feet.<br />

Detailed drawing,<br />

available on the Internet.<br />

NEW<br />

U (HE) 24 42 42 42 42<br />

Width (B) mm 1) 600 600 600 800 800<br />

Height (H) mm 1) 1200 2000 2000 2000 2000<br />

Depth (T) mm 1) 1000 1000 1000 1000 1000<br />

Distance between 482.6 mm (19˝) levels in its delivered state A mm 745 745 745 745 745<br />

Model No. TE<br />

RAL 7035 – 7000.882 – 7000.892 –<br />

as bayed enclosure without side panels, including baying kit RAL 9005 – – 7000.885 – 7000.895<br />

Model No. TE as small enclosure including side panels RAL 7035 7000.875 – – – –<br />

Doors<br />

Sheet steel door front and rear, fully vented; open surface area > 67% perforated <br />

Roof<br />

Roof plate including brush strip for cable entry and with an optional fan <br />

Base<br />

Base frame with maximum cut-out for cable entry or passive ventilation.<br />

Can be fitted with optional blanking panels.<br />

<br />

Interior installation<br />

482.6 mm (19˝) mounting frames front and rear <br />

Accessories<br />

Side panels, pluggable, including security lock 3524 E 7000.653 7000.663 7000.653 7000.663<br />

Ergoform-S handle for semi-cylinder, to exchange for the existing lock 2435.000 2435.000 2452.000 2) 2435.000 2452.000 2)<br />

Fan unit, with 2 fans and thermostat, pre-wired ready for connection 7000.670 7000.670 7000.671 3) 7000.670 7000.671 3)<br />

Transport castors, 4 castors including assembly parts 7000.672 7000.672 7000.672 7000.672 7000.672<br />

C rail, for cable clamping in the enclosure width via cable clamps,<br />

on the 482.6 mm (19˝) mounting frame at the rear<br />

7828.060 7828.060 7828.060 7828.060 7828.060<br />

Cable clamp rail, depth-variable 500 – 895 mm,<br />

for cable attachment in the enclosure depth via cable ties<br />

7858.162 7858.162 7858.162 7858.162 7858.162<br />

Cable clamp rail, for cable attachment in the enclosure width via cable ties,<br />

on the 482.6 mm (19˝) mounting frame at the rear<br />

7828.062 7828.062 7828.062 7828.062 7828.062<br />

Earthing kit for TE 7000.675 7000.675 7000.675 7000.675 7000.675<br />

TE socket strip, 8-way for earthing-pin plugs 7000.630 7000.630 7000.630 7000.630 7000.630<br />

Included with the supply. 1) All sizes are nominal dimensions. For absolute dimensions, refer to detailed drawings on the Internet. 2) Matt nickel-plated.<br />

3) Delivery times available on request.<br />

14 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Server racks


Server racks<br />

Based on <strong>Rittal</strong> TS 8, pre-configured<br />

T<br />

B<br />

H<br />

Design features:<br />

● Robust frame structure<br />

● Front and rear door vented<br />

across the entire surface;<br />

180° hinges<br />

● 482.6 mm (19˝) mounting<br />

frame<br />

● 4-point locking<br />

● Door hinge may be swapped<br />

to opposite side<br />

● Cable entry via the roof<br />

and base<br />

● Bayable at all levels<br />

● Static load capacity<br />

of up to 1000 kg<br />

1<br />

Material:<br />

Sheet steel<br />

Surface finish:<br />

Enclosure frame:<br />

Dipcoat-primed<br />

Enclosure panels:<br />

Dipcoat-primed, powder-coated<br />

in RAL 7035 or RAL 9005<br />

482.6 mm (19˝) mounting frame:<br />

Zinc-plated, passivated<br />

Supply includes:<br />

Enclosure frame TS 8<br />

with sheet steel doors,<br />

one-piece vented at front,<br />

vertically divided vented at rear,<br />

Levelling feet, both sides<br />

<strong>Co</strong>mfort handle with security<br />

lock 3524 E and 4-point locking.<br />

Enclosure panel earthing<br />

prefitted.<br />

Two-piece roof plate, with<br />

sliding plate and rubber cable<br />

clamp strip for cable entry.<br />

Without or with side panels in<br />

colours RAL 7035/RAL 9005.<br />

Detailed drawing,<br />

available on the Internet.<br />

1 Optimised airflow.<br />

Open surface area > 78%<br />

perforated.<br />

NEW<br />

NEW<br />

Number of front doors 1 1 1 1 1 1<br />

No. of rear doors (vertically divided) 2 2 2 2 2 2<br />

U 42 42 42 42 47 47<br />

Width (B) mm 800 800 800 800 800 800<br />

Height (H) mm 2000 2000 2000 2000 2200 2200<br />

Depth (T) mm 1200 1200 1200 1200 1000 1000<br />

Model No. DK 7831.730 7831.732 7831.740 1) 7831.742 1) 7831.752 7831.762 1)<br />

RAL colour 7035 7035 9005 9005 7035 9005<br />

Doors<br />

Sheet steel doors, vented, front and rear <br />

Plug-in side panels with T lock – – 7824.220 7816.220 1)<br />

Roof<br />

Roof plate, two-piece with rubber cable clamp strip for cable entry <br />

Base<br />

Open base, without base frame <br />

Levelling feet <br />

Interior installation<br />

482.6 mm (19˝) mounting frames front and rear <br />

L-shaped mounting angles – – – – – –<br />

Mounting angles attached to depth stays – – – – – –<br />

482.6 mm (19˝) mounting frames front and rear <br />

Load capacity 1000 kg, static <br />

Panel earthing, fitted <br />

Accessories<br />

Security lock for side panels 7824.500 7824.500 7824.500 7824.500 7824.500 7824.500<br />

Base/plinth components, front and rear, solid 8601.805 8601.805 8601.802 8601.802 8601.805 8601.802<br />

Base/plinth trims 8601.025 8601.025 8601.026 8601.026 8601.015 8601.010<br />

Base attachment bracket 8800.210 8800.210 8800.210 8800.210 8800.210 8800.210<br />

Stabiliser, pull-out 7825.260 7825.260 7825.260 7825.260 7825.250 7825.250<br />

Included with the supply 1) Delivery times available on request.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Server racks<br />

15


Server racks<br />

Based on <strong>Rittal</strong> TS 8, Plus<br />

B<br />

T<br />

H<br />

2<br />

1<br />

Rear view<br />

1<br />

2<br />

Optimised air flow.<br />

Open surface area > 78%<br />

perforated.<br />

Benefits:<br />

The pre-configured TS 8 server<br />

rack Plus provides plenty of<br />

space for the installation of deep<br />

servers or blade systems. The<br />

800 mm width and standard<br />

accessories facilitate flexible<br />

cable routing. The vented front<br />

door with filter mat protects the<br />

built-in <strong>IT</strong> components from contamination.<br />

In combination with<br />

the noise reduction door, it is<br />

suitable for use in office environments.<br />

In this way, the entire <strong>IT</strong><br />

infrastructure of a small company<br />

may be securely housed.<br />

Thanks to the twin castors fitted<br />

as standard, the rack may be<br />

used flexibly in terms of location.<br />

Material:<br />

Sheet steel<br />

Surface finish:<br />

Enclosure frame and enclosure<br />

panels:<br />

Dipcoat-primed, powder-coated<br />

in RAL 9005<br />

Supply includes:<br />

TS 8 enclosure frame with<br />

vented sheet steel door at the<br />

front, including vented noise<br />

reduction door at the rear, with<br />

130° hinges, 2 x 482.6 mm (19˝)<br />

mounting frames, plug-in side<br />

panels with security lock 3524 E,<br />

levelling feet, twin castors,<br />

system accessories for cable<br />

routing, comfort handle with<br />

security lock 3524 E and 2-point<br />

lock.<br />

Design features:<br />

● Robust frame structure<br />

● Front door fully vented, including<br />

filter mat to protect the<br />

built-in components<br />

● Rear door including sound<br />

insulation mats to reduce<br />

noise<br />

● 2-point locking<br />

● Door hinge may be swapped<br />

to opposite side<br />

● Cable entry via the roof and<br />

base<br />

● Side panels, pluggable,<br />

including security lock 3524 E<br />

● Bayable at all levels<br />

● With levelling feet, will withstand<br />

static loads of up to<br />

1000 kg<br />

● Max. transport load 360 kg<br />

with twin castors<br />

● System accessories for cable<br />

routing<br />

U 24<br />

Width (B) mm 800<br />

Height (H) mm 1200<br />

Depth (T) mm 1200<br />

Distance between 482.6 mm (19˝) levels in its delivered state mm 740<br />

Model No. DK with vented noise reduction door, rear 7831.850<br />

Side panels<br />

Side panels, plug-type, RAL 9005<br />

<br />

Doors<br />

Sheet steel door, vented, front, including filter mat<br />

<br />

Noise reduction door, vented, rear<br />

<br />

<strong>Co</strong>mfort handle with security lock, front and rear<br />

<br />

Roof<br />

Roof plate for cable entry<br />

<br />

Base<br />

4 castors (2 of them lockable) <br />

Levelling feet<br />

<br />

Open base, without base frame<br />

<br />

Interior installation<br />

482.6 mm (19˝) mounting frames front and rear <br />

Panel earthing, fitted<br />

<br />

Accessories<br />

10 cable shunting rings <br />

10 cable routing bars, 1 U <br />

50 captive nuts M6, conductive <br />

50 multi-tooth screws M6 x 16 with plastic washers <br />

Slide rails, depth-variable, 590 – 930 mm, load capacity 150 kg 7063.884<br />

482.6 mm (19˝) component shelf, D = 700 mm, load capacity 100 kg, RAL 9005 7063.837<br />

Installation kit depth-variable 706 – 1006 mm for 482.6 mm (19˝) component shelf 100 kg 7063.890<br />

Telescopic slides for component shelf DK 7063.837/DK 7063.897 7066.700<br />

Cable support, hinged, with anti-kink guard 7163.565<br />

Included with the supply. For more accessories, refer to <strong>Rittal</strong> <strong>IT</strong> Catalogue.<br />

16 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Server racks


Server racks<br />

Based on <strong>Rittal</strong> TS 8, High Performance <strong>Co</strong>oling systems HPC<br />

T1<br />

B1<br />

B2<br />

H2<br />

H1<br />

T2<br />

High Performance <strong>Co</strong>oling<br />

systems HPC:<br />

Glazed aluminium front door<br />

(180°),<br />

with 3 mm toughened safety<br />

glass, sheet steel rear door<br />

(130°), <strong>Co</strong>mfort handle on both<br />

sides for semi-cylinder and<br />

security lock 3524 E. 482.6 mm<br />

(19˝) mounting frame front and<br />

rear, distance between levels<br />

pre-configured 740 (500) mm,<br />

space to front door approx.<br />

100 mm.<br />

Max. static load capacity of the<br />

interior installation 1000 kg, static<br />

per rack. Roof plate, two-piece,<br />

for cable entry via sliding plate.<br />

Multi-divided base/gland plate.<br />

Maximum attainable protection<br />

category IP 54, in conjunction with<br />

solid roof (bayed solution) and<br />

additional screw-fastened side<br />

panels with stand-alone siting.<br />

Material:<br />

Sheet steel<br />

Surface finish:<br />

Dipcoat-primed, panels<br />

additionally powder-coated,<br />

RAL 7035.<br />

Gland plates and 482.6 mm (19˝)<br />

mounting frame zinc-plated,<br />

passivated<br />

NEW<br />

Supply includes:<br />

Enclosure frame with doors and<br />

rear panel, roof plate, gland<br />

plate, 482.6 mm (19˝) interior<br />

installation, earthing of all<br />

panels, levelling feet, fitted.<br />

U 42 42 42 42 42<br />

Width (B1) mm 1) 600 600 800 800 800<br />

Height (H1) mm 1) 2000 2000 2000 2000 2000<br />

Depth (T1) mm 1) 1000 1200 800 1000 1200<br />

Clearance width (B2) mm 512 512 712 712 712<br />

Clearance height (H2) mm 1912 1912 1912 1912 1912<br />

Clearance depth (T2) mm 912 1112 712 912 1112<br />

Model No. DK as bayed enclosure without side panels,<br />

without baying kit<br />

7831.810 7831.812 7831.830 2) 7831.800 7831.802<br />

Model No. DK with side panels, screw-fastened – 7831.813 – – 7831.803<br />

Doors<br />

Aluminium glazed front door, sheet steel rear door <br />

Roof<br />

Roof plate for cable entry, two-piece <br />

Base<br />

Levelling feet <br />

Base frame with multi-piece gland plate <br />

Interior installation<br />

482.6 mm (19˝) levels front and rear <br />

L-shaped mounting angles – – – – –<br />

Mounting angles attached to depth stays – – – – –<br />

482.6 mm (19˝) mounting frames front and rear <br />

Panel earthing, fitted <br />

Accessories<br />

Side panel, screw-fastened, IP 55 8100.235<br />

<br />

(7831.813 only)<br />

8108.235 8100.235<br />

<br />

(7831.803 only)<br />

Depth-variable slide rail, 1 U, length 590 – 930 mm, 80 kg, static, packs of 2 7063.883 7063.883 7063.882 7063.883 7063.883<br />

482.6 mm (19˝) heavy duty base, 500/700 mm deep,<br />

100 kg load capacity 1)<br />

7063.897 7063.897 7063.895 7063.897 7063.897<br />

Installation kit for heavy-duty component shelf, depth-variable 7063.890 7063.890 7063.860 7063.890 7063.890<br />

Included with the supply.<br />

1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet. 2) Delivery times available on request.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Server racks<br />

17


Power<br />

Active Power System Module PSM/Power <strong>Co</strong>ntrol Unit PCU<br />

Plug-in modules<br />

TCP/IP<br />

Intelligent power management<br />

with the <strong>Rittal</strong> PSM/PCU system<br />

Switching and measuring at individual server level<br />

During times of rising energy costs, operators need to be very aware<br />

of the performance data of their hardware. With this in mind, <strong>Rittal</strong><br />

has extended its range of active PSM modules with switching option<br />

to include the feature of current measurement per outlet slot. This<br />

supports targeted data logging and response down to individual<br />

equipment level.<br />

With the new active modules, which are compatible with existing<br />

PSM modules, it is now possible to monitor the current power consumption<br />

of individual servers and peripheral hardware at a glance.<br />

The respective outgoing output is displayed visually via two LEDs<br />

per slot based on the “traffic light” principle (green, amber, red).<br />

Additionally, the overall current of the module can be read from a<br />

7-segment display in the upper area of the module. The individual<br />

slot limits may be retrieved online via the CMC-TC system. An upper<br />

limit for the entire module may also be set. Once this is reached, all<br />

LEDs on the active module switch to red so that no further equipment<br />

is connected.<br />

Networking capability of active modules via the CMC-TC system<br />

In conjunction with the <strong>Rittal</strong> CMC-TC Processing Unit II, up to<br />

16 active PSM/PCU modules may be managed via TCP/IP.<br />

Event-controlled linking e.g. of switching states with other CMC-TC<br />

sensors (e.g. temperature) is also supported.<br />

<strong>Co</strong>nnection recommendations<br />

In order to ensure problem-free operation and the maximum connected<br />

load (22 kW) of the PSM bar, it is essential to ensure that a<br />

separate circuit with 16 A fuse is allocated to each module installed<br />

in the PSM bar (this is possible with 2 x three-phase 16 A infeed to<br />

the PSM bar by refraining from populating the 7th (8th) slot).<br />

For active PSM/PCU modules that are controlled via the CMC-TC<br />

system, the default values of the output ranges may be modified.<br />

These limits may be adapted to the respective equipment environment.<br />

The values may be configured here in 0.1 A increments up<br />

to 10 A (15 A) via the CMC-TC web interface!<br />

Note:<br />

Detailed information on the supply scope of the <strong>Rittal</strong> PSM system<br />

may be found in the <strong>IT</strong> Catalogue, from page 99, and in Catalogue 32,<br />

from page 789.<br />

Further information on the CMC-TC may be found in the <strong>IT</strong> Catalogue,<br />

from page 153 and in Catalogue 32, from page 806.<br />

Processing Unit II<br />

Green LEDs indicate that power<br />

is being supplied to the PSM<br />

module, and a low current flow<br />

of between 0.1 A and 7 A has<br />

been detected on the slot of that<br />

module. Other equipment may<br />

now be safely connected.<br />

Amber LEDs indicate an increased<br />

current flow of between<br />

7 A and 13 A on the slot. The<br />

power consumption of all equipment<br />

connected to the module<br />

must not exceed 3000 W. Before<br />

connecting other equipment,<br />

please note its connected load.<br />

Red LEDs indicate that the<br />

threshold of 13 A has been<br />

exceeded. No further equipment<br />

must be connected in<br />

order to avoid overloading and<br />

tripping of the prefuses.<br />

Note:<br />

The limits of the visual display may be set to customer-specific requirements<br />

via the CMC-TC system. If an upper limit has been set for<br />

the overall output of the module and this limit is reached, all LEDs on<br />

the module will automatically switch to red.<br />

18 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Power


Power<br />

Active Power System Module PSM/Power <strong>Co</strong>ntrol Unit PCU<br />

<strong>Co</strong>mmon features<br />

of the active PSM/PCU modules in conjunction<br />

with the CMC-TC<br />

● 2-digit local LED 7-segment current display.<br />

● Individual current measurement per slot with<br />

limit configuration via CMC-TC web interface.<br />

● LED colour code for fast load assessment per<br />

module, and (new): per slot.<br />

● SNMP switching option via the network.<br />

● Up to 16 modules via a joint web interface<br />

under one IP address (up to 4 modules of the<br />

same type per port).<br />

● Measuring and monitoring of the current per<br />

module and outgoing slot.<br />

● Limits (range limits, signalling via coloured<br />

LED) may be freely configured.<br />

● The 8/4 1) individual slots of the module may be<br />

switched separately in conjunction with the<br />

CMC-TC. May also be linked to other CMC-TC<br />

alarm messages.<br />

● Alarm messages are additionally indicated by<br />

flashing LEDs.<br />

● Up to 16 modules may be administered with<br />

one CMC-TC system via a shared IP address.<br />

Also required:<br />

CMC-TC Processing Unit II, DK 7320.100<br />

wide-range power pack (sec. 24 V DC),<br />

DK 7320.425<br />

1 U mounting unit, DK 7320.440<br />

<strong>Co</strong>nnection cable (Cat 5), DK 7320.472<br />

CMC-TC programming cable, DK 7320.221<br />

<strong>Co</strong>nnection cable (DE) 230 V AC, DK 7320.210<br />

1) There are additionally 2 x IEC 60 320 C13 slots<br />

(IEC 320 connection) available per module.<br />

Plug-in modules, active PSM<br />

with individual current measurement<br />

(IP-compatible in conjunction with CMC-TC)<br />

Module with 8/4 1) slots, individually switchable or<br />

logging of individual currents per outgoing slot<br />

(C13/C19) via the <strong>Rittal</strong> CMC-TC. These active,<br />

switchable modules each occupy 2 slots in the<br />

PSM bar, and therefore, up to 3 (2) modules<br />

may be installed in a PSM busbar for 2000 mm<br />

(1200 mm) high racks. <strong>Co</strong>mbined population of<br />

different modules is also supported. A maximum<br />

of 16 modules may be administered via one IP<br />

address.<br />

Material:<br />

Aluminium section with black plastic cover<br />

Supply includes:<br />

PSM plug-in module, instructions, bus cable.<br />

Plug-in module Number of slots Model No. DK<br />

IEC 60 320 C13 8 7859.222<br />

IEC 60 320 C19 4 1) 7859.232<br />

1) There are additionally 2 x IEC 60 320 C13 slots<br />

(IEC 320 connection) available.<br />

Note:<br />

Operating the module without CMC-TC<br />

(local current display in the rack)<br />

For operation of the socket strip, power pack<br />

DK 7201.210 and a mains cable (country-specific)<br />

is required. Up to 4 modules may be<br />

operated with one power pack. However, configuration<br />

of the individual limits is only possible<br />

via the CMC-TC. A PSM busbar is required to<br />

operate.<br />

<strong>Rittal</strong> Power <strong>Co</strong>ntrol Unit<br />

with individual current measurement<br />

(PCU, IP-compatible in conjunction<br />

with CMC-TC)<br />

Module with 8/4 1) slots, individually switchable<br />

or logging of individual currents per outgoing slot<br />

(C13/C19) via the <strong>Rittal</strong> CMC-TC. This module<br />

may be mounted both within the 482.6 mm (19˝)<br />

level and on the enclosure frame (zero-U).<br />

Material:<br />

Aluminium section with black plastic cover<br />

Supply includes:<br />

PCU 482.6 mm (19˝) module, bus cable,<br />

instructions, assembly parts for 482.6 mm (19˝)<br />

installation, connector.<br />

Plug-in module Number of slots Model No. DK<br />

IEC 60 320 C13 8 7859.225<br />

IEC 60 320 C19 4 1) 7859.235<br />

1) There are additionally 2 x IEC 60 320 C13 slots<br />

(IEC 320 connection) available per module.<br />

Note:<br />

Operating the PCU without CMC-TC<br />

(local current display in the rack)<br />

For operation of the socket strip, power pack<br />

DK 7201.210 and a mains cable (country-specific)<br />

are required. Up to 4 modules may be<br />

operated with one power pack. However, configuration<br />

of the individual limits is only possible<br />

via the CMC-TC.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Power<br />

19


Power<br />

Power System Module PSM<br />

PSM busbar<br />

with fixed infeed, 3-phase<br />

Busbar with fixed connection cable for strain<br />

relief. The existing DIN screw fastening prevents<br />

the cable from being pulled out accidentally.<br />

<strong>Co</strong>nnection is made using a 3 m connection cable<br />

with open cable ends.<br />

Supply includes:<br />

Busbar with fixed connection cable,<br />

assembly instructions, assembly parts.<br />

For<br />

enclosure<br />

height<br />

mm<br />

Power<br />

supply<br />

Also required:<br />

Maximum<br />

no. of<br />

modules<br />

PSM plug-in modules,<br />

see <strong>IT</strong> Catalogue, page 100 – 102.<br />

Model No.<br />

DK<br />

2000 3 x 16 A 7 7856.005<br />

2000 2 x 3 x 16 A 7 7856.006<br />

PSM busbar<br />

for 47 U rack, 3-phase<br />

PSM busbar in special versions for 47 U racks.<br />

The 2100 mm high busbar offers 8 slots for PSM<br />

modules.<br />

Technical specifications:<br />

● 3-phase infeed construction with a maximum<br />

current of 3 x 16 A<br />

● A redundant three-phase infeed with 3 x 16 A<br />

may also be added<br />

● The redundant circuit is completely separate<br />

from the 3 phases of the support rail<br />

Supply includes:<br />

Busbar, assembly instructions, assembly parts.<br />

Without cable.<br />

For<br />

enclosure<br />

height<br />

mm<br />

Power<br />

supply<br />

Also required:<br />

Maximum<br />

no. of<br />

modules<br />

<strong>Co</strong>nnection cable, PSM plug-in modules,<br />

see <strong>IT</strong> Catalogue, page 100 – 102.<br />

Model No.<br />

DK<br />

2200 2 x 3 x 16 A 8 7856.008<br />

PSM busbar<br />

with measurement<br />

Single-phase, 32 A<br />

Busbar with integral output measurement to<br />

display and monitor the entire connected current<br />

of the PSM bar. The display is local. The bar is<br />

remotely administrable and configurable in conjunction<br />

with the CMC-TC system.<br />

The following active functions are provided:<br />

● Local display<br />

● Measurement and monitoring of the current<br />

and voltage. Adjustable limits.<br />

Measurement range 0 – 16 A/0 – 250 V<br />

● Alarm notifications via a flashing display<br />

● Remote administration of the bar supported<br />

(in conjunction with the CMC-TC)<br />

Supply includes:<br />

Busbar with fixed connection cable,<br />

with CE connector (32 A), instructions,<br />

assembly parts.<br />

For<br />

enclosure<br />

height<br />

mm<br />

Power<br />

supply<br />

Note:<br />

In stand-alone mode without CMC-TC, a separate<br />

power pack DK 7201.210 with connection cables<br />

is required.<br />

Also required:<br />

Maximum<br />

no. of<br />

modules<br />

PSM plug-in modules,<br />

see <strong>IT</strong> Catalogue, page 100 – 102,<br />

CMC-TC system, see <strong>IT</strong> Catalogue,<br />

from page 153.<br />

Model No.<br />

DK<br />

2000 1 x 32 A 6 7856.003<br />

20 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Power


Power<br />

Power System Module PSM<br />

New requirements for connectors<br />

and connector strips to<br />

DIN VDE 0100-410<br />

On 1 June 2007, new requirements on fault protection<br />

in sockets and connector strip systems<br />

came into force under DIN VDE 0100-410. This<br />

standard prescribes additional protection from an<br />

RCD (Residual Current protective Device) on all<br />

sockets “intended for use by laypersons and for<br />

general use”.<br />

Exceptions to this rule are “sockets that are<br />

monitored by electricians or persons who have<br />

received instruction in electrical engineering”,<br />

such as commercial or industrial plants. In this<br />

regard, “monitored” refers to “plant and operating<br />

equipment that is maintained by qualified electricians”.<br />

Here, the use of mains voltage-independent RCDs<br />

with a rated differential current of 30 mA is advised.<br />

<strong>Rittal</strong> advises customers to check their<br />

respective applications against these requirements,<br />

and where necessary, to incorporate<br />

suitable safety devices.<br />

For applications requiring such additional protection,<br />

<strong>Rittal</strong> offers the following plug & go products.<br />

PSM busbar<br />

with fixed infeed/RCD<br />

Busbar with Residual Current protective Device<br />

(RCD). The busbar is protected against inadmissibly<br />

high touch voltages by two RCDs with a rated<br />

differential current of 30 mA. One RCD protects<br />

3 slots on the bar. Additionally, there are two 16 A<br />

miniature circuit-breakers integrated into the bar.<br />

Infeed is via a 32 A CE connector.<br />

Supply includes:<br />

Busbar with 3 m fixed connection cable,<br />

instructions, assembly parts.<br />

For<br />

enclosure<br />

height<br />

mm<br />

Power<br />

supply<br />

Also required:<br />

Plug-in module PSM,<br />

see page 21.<br />

Maximum<br />

no. of<br />

modules<br />

Model No.<br />

DK<br />

2000 1 x 32 A 6 7856.043<br />

Extended delivery times.<br />

PSM plug-in module<br />

with integral RCD<br />

PSM module with integral RCD. The rated differential<br />

current of the RCD is 30 mA. The module<br />

occupies 2 module slots on the PSM bar.<br />

Plug-in module<br />

Number<br />

of sockets<br />

Model No.<br />

DK<br />

EN 60 320 C13 8 x C13 7856.095<br />

Extended delivery times.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Power<br />

21


Power<br />

UPS, <strong>Rittal</strong> Modular Power <strong>Co</strong>ncept – PMC 40<br />

11 HE<br />

15 HE<br />

18 HE<br />

26 HE<br />

19˝<br />

19˝<br />

19˝<br />

19˝<br />

HE = U<br />

PMC 40 – compact, rackindependent<br />

UPS system<br />

(up to 40 kW, 3-phase)<br />

This uses “double conversion”<br />

UPS technology according to<br />

the highest classification VFI-SS-<br />

111, which provides a constant<br />

output irrespective of the incoming<br />

voltage, coupled with a high<br />

overall efficiency and minimal<br />

space requirements.<br />

The PMC 40 may be configured<br />

as a redundant system (decentralised<br />

parallel architecture,<br />

DPA) for maximum availability of<br />

the plant (redundant protection –<br />

without “Single Point Of Failure”).<br />

All PMC 40 UPS components<br />

are mounted directly in the<br />

482.6 mm (19˝) level of a rack<br />

at least 800 mm deep. This ensures<br />

enclosure independence.<br />

Depending on the equipment,<br />

mixed population (e.g. with<br />

servers) in the same rack is also<br />

supported.<br />

The PMC 40 (redundant version)<br />

has “safe-swap” capabilities.<br />

This allows easy, safe<br />

module exchange while the<br />

system is operational, without<br />

having to switch the UPS to<br />

bypass mode.<br />

However, parallel switching of<br />

several PMC 40 UPS systems,<br />

as with the PMC 200, is not supported.<br />

As a general principle, it is<br />

important to ensure adequate<br />

climate control of the rack into<br />

which the PMC 40 is installed.<br />

For installation purposes, the<br />

rack must have two 482.6 mm<br />

(19˝) mounting levels and a minimum<br />

depth of 800 mm.<br />

Installation, commissioning and<br />

maintenance must only be carried<br />

out by qualified personnel<br />

who have been authorised by<br />

<strong>Rittal</strong>.<br />

Supply includes:<br />

A PMC 40 UPS system is<br />

comprised of a basic unit for<br />

482.6 mm (19˝) installation.<br />

1 –2 UPS modules and, depending<br />

on the version, a maximum<br />

of two battery packs per UPS<br />

module may be integrated into<br />

this basic module. The configured<br />

complete system comes<br />

supplied with basic unit and<br />

UPS module(s). The battery<br />

packs are supplied separately.<br />

PMC 40 modules, rack-independent<br />

min. 800<br />

The UPS system<br />

PMC 40 may be installed<br />

in any 482.6 mm<br />

(19˝) rack which is at<br />

least 800 mm deep.<br />

Basic module . . . . . . plus UPS module . . . . . . plus battery pack<br />

produce a complete<br />

UPS system with an<br />

output of 10 – 40 kW.<br />

Installation examples<br />

The UPS system PMC 40 may . . . a network enclosure . . . . . . or a mixed environment.<br />

be installed directly into an<br />

existing server rack . . .<br />

Note: When installing the PMC 40 in a closed enclosure, it is important to ensure adequate climate control.<br />

22 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Power


Power<br />

UPS, <strong>Rittal</strong> Modular Power <strong>Co</strong>ncept – PMC 40<br />

Type 1 Type 2 Type 3 Type 4<br />

UPS output with 1 + 1 redundancy (with 10 kW/20 kW module) kW not possible not possible 10/20 10/20<br />

UPS modules/battery packs Qty. 1/1 1/2 2/2 2/2 2/4 2/4<br />

Maximum UPS output (with 10 kW/20 kW module) kW 10/20 10/20 20 40 20 40<br />

Redundancy without without with without with without<br />

Width (W) mm 485 (19˝) 485 (19˝) 485 (19˝) 485 (19˝)<br />

Height (H) U 11 15 18 26<br />

Depth (D) mm 740 740 740 740<br />

Model No. DK<br />

basic unit<br />

Model No. DK<br />

PMC 40 10 kW module (quantity acc. to type) 1)<br />

Model No. DK<br />

PMC 40 20 kW module (quantity acc. to type) 1)<br />

Model No. DK<br />

battery pack 4 x 10 batteries (12 V/7 Ah) prewired<br />

(service life 5 acc. to EUROBAT) Order quantity acc. to type!<br />

Model No. DK<br />

battery pack 4 x 10 batteries (12 V/7 Ah) prewired<br />

(service life 10 acc. to EUROBAT) Order quantity acc. to type!<br />

7040.010 7040.020 7040.030 7040.040<br />

1 x<br />

7040.110<br />

1 x<br />

7040.120<br />

1 x<br />

7040.200<br />

1 x<br />

7040.210<br />

1 x<br />

7040.110<br />

1 x<br />

7040.120<br />

2 x<br />

7040.200<br />

2 x<br />

7040.210<br />

2 x<br />

7040.110<br />

2 x<br />

7040.120<br />

2 x<br />

7040.200<br />

2 x<br />

7040.210<br />

2 x<br />

7040.110<br />

2 x<br />

7040.120<br />

4 x<br />

7040.200<br />

4 x<br />

7040.210<br />

Approx. autonomies at 100% load (10 kW/20 kW module) min. 8/3 18/8 8/3 18/8<br />

Approx. autonomies at 50% load (10 kW/20 kW module) min. 18/8 45/18 18/8 45/18<br />

RS232 (D-Sub 9) and USB interface (configuration and shutdown) Qty. 1/1 1/1 1/1 1/1<br />

Fault signal contacts (floating) Qty. 5 5 5 5<br />

Clamping strip input (3L+N+PE) max. conductor cross-section mm 2 10/16 10/16 10/16 10/16<br />

Clamping strip output (3L+N+PE) max. conductor cross-section mm 2 10/16 10/16 10/16 10/16<br />

Required distance between 482.6 mm (19˝) levels (min./max.) mm 690 – 800 690 – 800 690 – 800 690 – 800<br />

Weight (approx. incl. batteries and UPS modules) kg 160 260 285 485<br />

Accessories<br />

SNMP monitoring card (Budget) 7857.420<br />

RCCMD licence, bundle with 5 licences for selective shutdown of<br />

5 computers (only available in conjunction with UPS hardware)<br />

7857.423<br />

RCCMD licence, bundle with 25 licences for selective shutdown of<br />

25 computers (only available in conjunction with UPS hardware)<br />

7857.424<br />

1) Only modules of an identical output are available.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Power<br />

23


Power<br />

UPS, <strong>Rittal</strong> Modular Power <strong>Co</strong>ncept – PMC 40<br />

PMC 40 basic unit<br />

PMC 40 basic module + bypass<br />

One basic module is required per UPS system.<br />

The complete power distribution with fuse holders,<br />

input and output terminal block and mechanical<br />

maintenance bypass are pre-integrated. The<br />

basic unit has a slide-in slot for 1/2 PMC 40 UPS<br />

modules (10 kW/20 kW).<br />

There are 4 versions available for a maximum output<br />

of 20 kW and 40 kW.<br />

Additionally, there is a slot provided in the basic<br />

unit for an SNMP monitoring card. A rack with two<br />

482.6 mm (19˝) mounting levels and a minimum<br />

depth of 800 mm is required for installation.<br />

Basic unit Battery packs Model No. DK<br />

20 kW 1 bat 7040.010<br />

20 kW 2 bat 7040.020<br />

40 kW 2 bat 7040.030<br />

40 kW 4 bat 7040.040<br />

Supply includes:<br />

Basic module, assembly instructions,<br />

482.6 mm (19˝) assembly parts.<br />

Also required:<br />

PMC 40 UPS module, PMC 40 battery pack.<br />

PMC 40 UPS module<br />

10 kW/20 kW<br />

This UPS module is inserted into the basic unit<br />

and latched. Depending on the basic unit, a maximum<br />

of two UPS modules are required. Modules<br />

of the same output must always be used. The<br />

modules are easily replaced, minimising maintenance<br />

and servicing times. Thanks to the “transformerless”<br />

double conversion UPS technology<br />

used (VFI-SS-111), these modules have a high<br />

level of efficiency coupled with a constant output<br />

behaviour, even if the equipment’s power factor is<br />

well into the capacitive or inductive range. There<br />

are two output categories (10 kW/20 kW) available.<br />

UPS module<br />

Model No. DK<br />

10 kW 7040.110<br />

20 kW 7040.120<br />

Supply includes:<br />

UPS module, instructions,<br />

assembly parts.<br />

Note:<br />

Technical specifications, see page 25.<br />

PMC 40 battery pack<br />

Battery pack for PMC 40 UPS modules<br />

1 to 2 battery packs may be connected per UPS<br />

module.<br />

This doubles the available autonomy of the PMC<br />

40 UPS system. The battery pack uses 4 x 10<br />

12 V/7 Ah lead gel batteries with a service life of<br />

5 or 10 years (to EUROBAT) which may be exchanged<br />

individually as and when necessary. A<br />

rack with two 482.6 mm (19˝) mounting levels and<br />

a minimum depth of 800 mm is required for installation.<br />

Battery pack<br />

service life<br />

Model No. DK<br />

5 years 7040.200<br />

10 years 7040.210<br />

UPS<br />

module output<br />

Autonomy 2)<br />

1 battery pack<br />

per UPS module<br />

Autonomy 2)<br />

2 battery packs<br />

per UPS module<br />

10 kW 8 min. 18 min.<br />

20 kW 3 min. 8 min.<br />

20 kW<br />

(10 kW + 10 kW) 1) 8 min. 18 min.<br />

40 kW<br />

(20 kW + 20 kW) 1) 3 min. 8 min.<br />

1) For parallel connection it is essential to use identical<br />

battery configurations per UPS module.<br />

2) All figures are for 100% load.<br />

For low capacity utilisation, e.g. 50%, the available<br />

autonomy is doubled accordingly. The autonomies are<br />

subject to normal fluctuations caused by unfavourable<br />

ambient temperatures, charges or battery ageing.<br />

24 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Power


Power<br />

UPS, <strong>Rittal</strong> Modular Power <strong>Co</strong>ncept – PMC 40<br />

Technical specifications 1)<br />

PMC 40 UPS module<br />

Model No. DK 7040.110 7040.120<br />

PMC 40 UPS module type 10 kW 20 kW<br />

Power output per module kW 10 20<br />

Input voltage V 3 x 400/230 + N<br />

Input voltage tolerance (at < 80% load) % –30/+15<br />

Input frequency range Hz 35 – 70<br />

Input power factor (at 100% load) min. PF = 0.99<br />

THDI % Sine-wave THDI = 4<br />

Max. input power (batteries charged, cos phi = 1.0) kW 10.5 21<br />

Max. input current (batteries charged, cos phi = 1.0) A 15.2 30.4<br />

Max. input power (batteries discharged, cos phi = 1.0) kW 11.6 23<br />

Max. input current (batteries discharged, cos phi = 1.0) A 16.8 33.6<br />

Max. output power (batteries charged, cos phi = 1.0) kW 10 20<br />

Max. output current (batteries charged, cos phi = 1.0) A 14.5 29<br />

Output power V 3 x 400/230<br />

Voltage stability (output) % +/– 4<br />

Distortions (output, non-linear load EN 62 040-3) % +/– 2<br />

Output frequency (configurable) Hz 50 or 60<br />

Output frequency tolerance range (not synchronised with input) Hz +/– 2<br />

Overload capacity on inverter (max. 600/60 sec.) % 125/150<br />

Short-circuit resistance<br />

Inverter: 2 x 250 ms bypass: 10 x in 10 ms<br />

Crest factor 3 : 1<br />

Ambient conditions<br />

Ambient temperatures (operation) °C 0 – 40<br />

Recommended operating conditions (batteries) °C 20 – 25<br />

Storage temperatures °C –25 – +70<br />

Relative humidity (non-condensing) % < 95<br />

Efficiency (AC – AC, approx. for at least 50% load) % 94<br />

Eco-mode efficiency at (AC – AC, at 100% load) % 98<br />

Interfaces (integrated into basic unit) USB, RS232, floating contacts (5)<br />

Optional management via extension slot (remote monitoring)<br />

1 x network monitoring card (SNMP card)<br />

Standards<br />

Safety EN 62 040-1.1, EN 60 950-1<br />

Electromagnetic compatibility EN 62 040-2, EN 61 000-3-2, EN 61 000-3-3, EN 61 000-6-2<br />

Certifications<br />

CE<br />

Protection category IP 20<br />

1)<br />

We reserve the right to make technical modifications.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Power<br />

25


<strong>Co</strong>oling<br />

Modular climate control concepts – to your specific<br />

requirements! <strong>Rittal</strong> solves the problem of climate control<br />

for high heat losses per rack with liquid cooling<br />

components. Extremely high heat loads are dissipated<br />

from the network enclosures and server racks via<br />

air/water heat exchangers.<br />

Additionally, this system allows data centres to be<br />

extended in a temperature-neutral way.<br />

Product<br />

Basic solutions<br />

CRAC systems<br />

LCP Extend<br />

LCP Inline<br />

LCP Standard/Smart<br />

LCP Plus/LCP T3+<br />

Low Density<br />

Your entry into professional<br />

<strong>IT</strong> climate<br />

control<br />

with aisle containment<br />

Mid Density<br />

The tailor-made solution<br />

for discerning data<br />

centres<br />

with aisle containment<br />

<strong>Co</strong>oling requirements<br />

High Density<br />

The most powerful solutions<br />

for high-end data centres.<br />

26 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/<strong>Co</strong>oling


LCP Inline<br />

The LCP Inline is designed for siting within<br />

a bayed enclosure suite. The hot air is drawn<br />

in from the room or hot aisle at the rear of the<br />

device and expelled at the front into the cold<br />

aisle after cooling. The LCP Inline achieves<br />

maximum performance and efficiency in conjunction<br />

with <strong>Rittal</strong> cold aisle containment.<br />

With this product, a raised floor is not necessary.<br />

LCP T3+/LCP T3+ EC<br />

Maximum reliability due to redundancies<br />

in cooling (Tier IV) and<br />

power supply (Tier III).<br />

At the heart of the LCP T3+ are two<br />

embedded cold water circuits,<br />

each of which supplies 100% of<br />

the nominal cooling output. The<br />

power supply to the fans also has<br />

a completely redundant layout.<br />

LCP Smart/LCP Plus EC<br />

These units provide reliable climate control<br />

and precise server loads up to 30 kW.<br />

Power LCP T3+ <strong>Co</strong>oling<br />

A<br />

A<br />

B<br />

B<br />

Redundant<br />

power supply<br />

Redundant<br />

cooling medium supply<br />

Benefits at a glance<br />

LCP T3+/LCP T3+ EC:<br />

● Two active cooling circuits and two<br />

switchable power circuits ensure the best<br />

possible resilience.<br />

● The built-in controllers are capable of<br />

adapting all device parameters automatically<br />

to preserve the required<br />

climate conditions.<br />

● A separate decentralised intelligence<br />

which automatically recognises emergency<br />

situations and responds correspondingly<br />

with the “auto-load balancing”<br />

and “auto-recovery” functions.<br />

LCP Plus EC:<br />

● <strong>Co</strong>mplete unit with 30 kW useful cooling<br />

output<br />

● Touchscreen<br />

● Basic CMC as standard<br />

LCP Smart:<br />

● <strong>Co</strong>mplete unit with 20 kW useful cooling<br />

output<br />

● Basic CMC as standard<br />

● Optional touchscreen<br />

LCP Inline:<br />

● <strong>Co</strong>mplete unit with 30 kW useful cooling<br />

output<br />

● No raised-floor climate control is required<br />

in the cold aisle<br />

All LCPs come with networking capability<br />

as standard, thanks to the Basic CMC with<br />

integral graphic user interface.<br />

Important<br />

● All enclosures are bayable with the<br />

corresponding TS 8 racks.<br />

● To ensure proper use of LCP components,<br />

the racks being cooled should be<br />

sealed against the ingress of ambient air<br />

wherever possible.<br />

For matching accessories,<br />

see hardcover catalogue<br />

“System Climate <strong>Co</strong>ntrol”, page 187.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/<strong>Co</strong>oling<br />

27


<strong>Co</strong>oling<br />

LCP Plus/LCP Plus EC, useful cooling output up to 40 kW<br />

B<br />

T<br />

H<br />

B = Width<br />

T = Depth<br />

Application and mode<br />

of operation:<br />

Air/water heat exchanger, bayable<br />

with server racks based on<br />

TS 8 (H x D: 2000 x 1200 mm).<br />

<strong>Co</strong>mplete unit with 40 kW useful<br />

cooling output.<br />

Benefits:<br />

● The separation of cooling and<br />

rack prevents water from<br />

penetrating the server rack.<br />

● Increased assembly- and<br />

service-friendliness<br />

● LCPs are easy to handle and<br />

may be transported in lifts and<br />

through doors.<br />

● The low weight means a minimal<br />

load area.<br />

● LCP Plus EC – the energyefficient<br />

variant of LCP Plus,<br />

fitted with extremely electricity-saving<br />

EC fan technology.<br />

Approvals,<br />

see hardcover catalogue<br />

“System Climate <strong>Co</strong>ntrol”,<br />

page 293.<br />

Model No. SK 3301.480 3300.480 1) on request<br />

Description LCP Plus LCP Plus EC LCP Plus<br />

Rated operating voltage Volt, Hz<br />

Dimensions in mm<br />

B<br />

H<br />

T<br />

230, 1~, 50/60<br />

400, 3~, 50/60<br />

300<br />

2000<br />

1200<br />

230, 1~, 50/60<br />

400, 3~, 50/60<br />

300<br />

2400<br />

1200<br />

Usable U 42 51<br />

Useful cooling output up to 30 kW up to 40 kW<br />

Rated current 9.3 A/10.4 A 5.2 A/5.8 A<br />

Pre-fuse 16 A/16 A 10 A/10 A<br />

<strong>Co</strong>oling medium<br />

Water<br />

(for specifications see Internet)<br />

Water inlet temperature<br />

+6°C to +20°C<br />

Permissible operating pressure p. max.<br />

5 bar<br />

Protection category to EN 60 529 IP 30<br />

Duty cycle 100%<br />

Electrical connection<br />

<strong>Co</strong>nnection cable<br />

Water connection<br />

1˝ external thread<br />

Weight<br />

230 kg<br />

<strong>Co</strong>lour RAL 7035<br />

Air throughput of fans 5000 m 3 /h<br />

Technical specifications<br />

available on request.<br />

Temperature control<br />

4-way fan control<br />

Linear fan control<br />

Two-way control valve<br />

Accessories Packs of SK Cat., page<br />

Add-on cover for height compensation<br />

with 2200 mm high racks<br />

1 3301.421 188<br />

Special voltages and sizes available on request. We reserve the right to make technical modifications.<br />

1)<br />

Delivery times available on request.<br />

28 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/<strong>Co</strong>oling


<strong>Co</strong>oling<br />

LCP Smart, useful cooling output up to 20 kW<br />

B<br />

T<br />

H<br />

B = Width<br />

T = Depth<br />

Application and mode<br />

of operation:<br />

The LCP Smart draws in the air<br />

at the sides of the server enclosure<br />

rear, cools it using highperformance<br />

compact registers,<br />

and blasts the cooled air back<br />

into the front part of the server<br />

enclosure at the sides.<br />

Maximum efficiency is achieved,<br />

thanks to the use of EC fans.<br />

The heat exchanger of the LCP<br />

Smart supports the longest<br />

possible usage of free cooling.<br />

Benefits:<br />

● High energy efficiency.<br />

● Bayable with server/network<br />

enclosures based on TS 8<br />

(H x D: 2000 x 1000 mm).<br />

● Fans may be individually<br />

exchanged with the system<br />

operational, self-contacting.<br />

● Basic CMC as standard.<br />

● Touchscreen display may be<br />

retrofitted.<br />

● Shorter servicing times.<br />

● Extended functionality of the<br />

monitoring and control technology/software.<br />

● Optimum adaptability thanks<br />

to dynamic, continuous control<br />

of the cold water volume<br />

flow.<br />

● <strong>Co</strong>ntrol of the inlet air temperature<br />

and the temperature difference<br />

for the best possible<br />

supply to your server systems.<br />

● Extremely robust thanks to its<br />

simple, optimised construction.<br />

Model No. SK 3301.460<br />

Rated operating voltage Volt, Hz<br />

230, 1~, 50/60<br />

400, 3~, 50/60<br />

Dimensions in mm<br />

B<br />

H<br />

T<br />

300<br />

2000<br />

1000<br />

Usable U 42<br />

Useful cooling output<br />

up to 20 kW<br />

Pre-fuse<br />

10 A<br />

Power consumption P el<br />

Max. 600 W<br />

<strong>Co</strong>oling medium<br />

Water<br />

Permissible operating pressure p. max.<br />

5 bar<br />

Duty cycle 100%<br />

Electrical connection<br />

<strong>Co</strong>nnection cable<br />

Water connection<br />

1˝ external thread<br />

Weight<br />

230 kg<br />

<strong>Co</strong>lour RAL 7035<br />

Temperature control<br />

Via integral controller<br />

Max. air throughput 3000 m 3 /h<br />

Touchscreen display<br />

for LCP Smart<br />

The display offers the opportunity of directly monitoring<br />

key functions of the LCP Smart, and implementing<br />

settings.<br />

Packs of<br />

Model No. SK<br />

1 3301.790<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/<strong>Co</strong>oling<br />

29


<strong>Co</strong>oling<br />

LCP Standard, useful cooling output up to 20 kW<br />

B<br />

T<br />

H<br />

B = Width<br />

T = Depth<br />

Application and mode<br />

of operation:<br />

Air/water heat exchanger, bayable<br />

with server racks based<br />

on TS 8 (H x D: 2000 x 1000/<br />

1200 mm).<br />

The useful cooling output of<br />

max. 20 kW can be achieved by<br />

installing additional modules.<br />

Benefits:<br />

● The separation of cooling and<br />

rack prevents water from<br />

penetrating the server rack.<br />

● Increased assembly- and<br />

service-friendliness.<br />

● LCPs are easy to handle<br />

(max. 2 m) and may be transported<br />

in lifts and through<br />

doors.<br />

● The low weight means a minimal<br />

load area.<br />

Approvals,<br />

see hardcover catalogue<br />

“System Climate <strong>Co</strong>ntrol”,<br />

page 293.<br />

Model No. SK 3300.420 3301.230 1) 3301.420<br />

Description<br />

LCP Standard<br />

Rated operating voltage Volt, Hz 230, 50/60<br />

Dimensions in mm<br />

B<br />

H<br />

T<br />

300<br />

2000<br />

800<br />

300<br />

2000<br />

1000<br />

Usable U 42<br />

Useful cooling output up to 15 kW 2) up to 20 kW<br />

300<br />

2000<br />

1200<br />

Rated current<br />

3.8 A/4.4 A<br />

Pre-fuse<br />

10 A/10 A<br />

<strong>Co</strong>oling medium<br />

Water (for specifications see Internet)<br />

Water inlet temperature<br />

+6°C to +20°C<br />

Permissible operating pressure p. max.<br />

5 bar<br />

Protection category to EN 60 529 IP 30<br />

Duty cycle 100%<br />

Electrical connection<br />

<strong>Co</strong>nnection cable<br />

Water connection<br />

3<br />

/ 4˝ external thread<br />

Weight<br />

Max. 160 kg<br />

<strong>Co</strong>lour RAL 7035<br />

Air throughput of fans 3000 m 3 /h<br />

Temperature control<br />

4-way fan control<br />

Electro-magnetic valve<br />

Accessories Packs of SK cat., page<br />

Add-on cover for height compensation<br />

with 2200 mm high racks<br />

1 – 3301.221 3301.421 188<br />

Special voltages and sizes available on request. We reserve the right to make technical modifications.<br />

1) Also available in 115 V, Model No. 3301.210.<br />

2)<br />

Unit is always fitted with 3 modules.<br />

<strong>Co</strong>oling module<br />

The cooling module allows the useful cooling output<br />

of the LCP Standard to be increased in 6.6 kW<br />

increments.<br />

Will not fit 800 mm deep LCP Standard.<br />

For detailed information, see hardcover catalogue<br />

“System Climate <strong>Co</strong>ntrol”, page 186.<br />

30 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/<strong>Co</strong>oling


<strong>Co</strong>oling<br />

LCP Inline, useful cooling output up to 30 kW<br />

T1<br />

B<br />

H<br />

B = Width<br />

T = Depth<br />

Application and mode<br />

of operation:<br />

The LCP Inline is designed for<br />

siting within a bayed enclosure<br />

suite. The hot air is extracted<br />

from the room or warm aisle at<br />

the rear of the unit, cooled, then<br />

blown out forwards into the cold<br />

aisle, where it is available to your<br />

<strong>IT</strong> equipment.<br />

The LCP Inline achieves maximum<br />

performance and efficiency<br />

in conjunction with <strong>Rittal</strong><br />

cold aisle containment. With this<br />

product, a raised floor is not<br />

necessary.<br />

Equipment:<br />

High-performance heat exchanger<br />

with very even temperature<br />

distribution.<br />

Integrated condensate management.<br />

<strong>Co</strong>ntroller with networking capability,<br />

compatible with all common<br />

communication standards<br />

(SNMP, BACnet etc.).<br />

Benefits:<br />

● <strong>Co</strong>mbines the slimline design<br />

of the LCP with the function of<br />

room air-conditioning.<br />

● Climate control technology,<br />

specially designed for <strong>IT</strong> environments<br />

with comprehensive<br />

monitoring functions.<br />

● Frame based on the popular<br />

TS 8 system.<br />

Model No. SK 3301.475 3301.470<br />

Rated operating voltage Volt, Hz<br />

230, 1~, 50/60<br />

400, 3~, 50/60<br />

Dimensions in mm<br />

B<br />

H<br />

T1<br />

300<br />

2000<br />

1066 (42˝)<br />

Usable U 42<br />

Useful cooling output<br />

up to 30 kW<br />

300<br />

2000<br />

1200<br />

Rated current<br />

9.3 A/10.4 A<br />

Pre-fuse<br />

16 A/16 A<br />

<strong>Co</strong>oling medium Water 1)<br />

Permissible operating pressure p. max.<br />

5 bar<br />

Duty cycle 100%<br />

Electrical connection<br />

<strong>Co</strong>nnection cable<br />

Water connection<br />

1˝ external thread<br />

Weight<br />

230 kg<br />

<strong>Co</strong>lour RAL 7035<br />

Temperature control<br />

Via integral controller<br />

Max. air throughput 4600/4300 m 3 /h<br />

1) Water quality according to unit specifications.<br />

Front cover<br />

The optional front cover, together with the built-in<br />

filter fleece, ensures an even air outlet at the sides<br />

as well, and reduces the air outlet speed, thus<br />

minimising draught effects.<br />

Packs of<br />

Model No. SK<br />

1 3301.980<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/<strong>Co</strong>oling<br />

31


<strong>Co</strong>oling<br />

LCP T3+/LCP T3+ EC, fully redundant, useful cooling output up to 24 kW<br />

B<br />

T<br />

H<br />

B = Width<br />

T = Depth<br />

Application and mode<br />

of operation:<br />

Air/water heat exchanger, bayable<br />

with server racks based on<br />

TS 8 (H x D: 2200 x 1200 mm).<br />

Benefits:<br />

● Efficient cooling of server<br />

racks with high thermal loads.<br />

● Fully redundant – Two active<br />

cooling circuits and two<br />

switchable power circuits<br />

ensure the best possible resilience.<br />

● The built-in controllers are<br />

capable of adapting all device<br />

parameters automatically to<br />

preserve the required climate<br />

conditions.<br />

● A separate decentralised<br />

intelligence which automatically<br />

recognises emergency<br />

situations and responds<br />

appropriately with the “autoload<br />

balancing” and “autorecovery”<br />

functions.<br />

● Interfaces which facilitate<br />

user-friendly operation and<br />

monitoring via the network or<br />

BSM systems.<br />

Optional:<br />

● Three-way control valve<br />

● Full BSM integration<br />

● Air filter system<br />

● Special colour<br />

Model No. SK 3300.230 3300.239<br />

Description LCP T3+ LCP T3+ EC<br />

Rated operating voltage V, Hz 230, 1~, 50/60<br />

Dimensions in mm<br />

B<br />

H<br />

T<br />

300<br />

2200<br />

1200<br />

Usable U 47<br />

Useful cooling output<br />

up to 24 kW<br />

Rated current 8.0 A/10.2 A 5.9 A/7.4 A<br />

Pre-fuse<br />

16 A/16 A<br />

Typical power consumption 1400 W 780 W<br />

<strong>Co</strong>oling medium<br />

Water<br />

(for specifications see Internet)<br />

Water inlet temperature<br />

+15°C to +21°C<br />

Permissible operating pressure p. max.<br />

5 bar<br />

Duty cycle 100%<br />

Electrical connection<br />

C19/C20<br />

Water connection<br />

1˝ external thread<br />

Weight<br />

215 kg<br />

<strong>Co</strong>lour RAL 7035<br />

Air throughput of fans 5000 m 3 /h 5000 m 3 /h<br />

4-way fan control<br />

Temperature control<br />

Two-way control valve<br />

Special voltages and sizes available on request. We reserve the right to make technical modifications.<br />

Linear fan control<br />

32 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/<strong>Co</strong>oling


<strong>Co</strong>oling<br />

Accessories for CRAC system<br />

<strong>Co</strong>nnection kit<br />

for connecting the <strong>Rittal</strong> CRAC system to the customer’s<br />

pipework when using water as a cooling<br />

medium.<br />

The connection kit is preassembled and is connected<br />

to an outgoing pipe with stop valve (to be<br />

provided by the customer) in both the inlet and<br />

outlet.<br />

Supply includes:<br />

Inlet side in the direction of flow<br />

● Sleeve with outer thread for screwing into the<br />

stop valve in the customer’s pipework.<br />

● Dirt trap to protect the equipment from dirt<br />

particles.<br />

● Turbine sensor to measure the water flow rate<br />

(used to determine the cooling output).<br />

● Screw connection with conical seal to allow the<br />

dismantling of components.<br />

● Stop valve to shut off the group of fittings.<br />

● High-pressure hose for flexible connection of<br />

the CRAC system with external thread for<br />

screwing into the equipment nozzle.<br />

Return side in the direction of flow<br />

● High-pressure hose for flexible connection<br />

of the CRAC system with external thread for<br />

screwing into the equipment nozzle.<br />

● Stop valve to shut off the group of fittings.<br />

● Screw connection with conical seal to allow<br />

the dismantling of components.<br />

● Line regulator valve to balance the climate<br />

control cold water system.<br />

For<br />

CRAC system<br />

Nominal<br />

width<br />

Model No.<br />

SK<br />

SK 3301.620 to 3301.650 1˝ 3300.260<br />

SK 3301.660 to 3301.690 1 1 / 4˝ 3300.261<br />

SK 3301.830 to 3301.860 1 1 / 2˝ 3300.262<br />

SK 3301.870 to 3301.990 2˝ 3300.263<br />

Energy-saving extractor<br />

plenum<br />

for top-mounting on CRAC systems.<br />

The extractor plenum is used to raise the extraction<br />

height of the return air and return it to the<br />

CRAC system at the highest possible temperature<br />

level. In this way, the energy efficiency of the<br />

unit can be increased significantly.<br />

The extractor plenum is comprised of an empty<br />

enclosure tailored to the width and depth of the<br />

CRAC system. The equipment enclosure and<br />

extractor plenum are screw-fastened together<br />

using the assembly kit supplied loose.<br />

Supply includes:<br />

Empty enclosure including assembly kit.<br />

For<br />

CRAC system<br />

Height<br />

mm<br />

Model No.<br />

SK<br />

SK 3301.620 to 3301.650 500 3300.290<br />

SK 3301.660 to 3301.690 500 3300.291<br />

SK 3301.830 to 3301.860 500 3300.292<br />

SK 3301.870 to 3301.990 500 3300.293<br />

SK 3300.510 to 3300.540 500 3300.294<br />

SK 3300.560 to 3300.590 500 3300.295<br />

SK 3300.710 to 3300.740 500 3300.296<br />

SK 3300.760 to 3300.790 500 3300.297<br />

Note:<br />

Special heights to adapt to the available room<br />

height are available on request.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/<strong>Co</strong>oling<br />

33


Security<br />

Monitoring system CMC-TC Processing Unit II plus<br />

CMC-TC Processing Unit II plus<br />

The Processing Unit II forms the basis of the<br />

CMC-TC system. This unit is required for every<br />

monitoring application. The PU II plus supports<br />

protocols IPv4 and IPv6, making it suitable for current<br />

and future IPv6 TCP-IP networks.<br />

Benefits:<br />

● Freely selectable monitoring functions<br />

● Sensor/actuator ports extendible<br />

● Network connection TCP/IP<br />

● Integral web server for configuration<br />

● Simple installation based on the plug & play<br />

system<br />

● Alarm continues to record even in the event of<br />

a network failure<br />

● Built-in real-time clock with NTP<br />

● May be used via power pack for<br />

100 – 240 V AC or 48 V DC<br />

● Choice of mounting on the enclosure frame<br />

or 482.6 mm (19˝) mounting angles<br />

● Master II interface TCP/IP SNMP<br />

● May be used for large data centres or small<br />

individual applications<br />

Interface to user:<br />

The PU II plus can be incorporated directly into<br />

the user network via 10/100BaseT. The PU II plus<br />

can also be linked to the master DK 7320.005 via<br />

this interface (TCP/IP, SNMP).<br />

Interface to the sensors/actuators:<br />

The PU II plus provides 4 open ports for sensor<br />

units. The sensor units determine the function of<br />

the PU II plus. There is a choice of 12 sensor units<br />

with different functions. In this way, the monitoring<br />

functions may be freely combined.<br />

Fast, easy programming and installation:<br />

The sensors/actuators are set up via an automatic<br />

electronic ID system. Installation is via a<br />

flexible plug & play system. This eliminates the<br />

need for time-consuming programming and<br />

wiring.<br />

Power supply:<br />

Power is supplied centrally via a power pack in<br />

the PU II plus. The connected sensor units and<br />

all connected sensors are supplied with power in<br />

this way. There is a choice of two input voltages<br />

(AC power pack DK 7320.425 and DC power<br />

pack DK 7320.435).<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

C<br />

IOIOI<br />

1 2 3 4<br />

CMC-TC<br />

Processing Unit II plus<br />

1 2 3 4 5 6 7<br />

1 2<br />

1<br />

P-I<br />

3 4<br />

2 C<br />

IOIOI<br />

Power<br />

24 V DC<br />

max. 2 A<br />

8 9 10 11 12<br />

<strong>Co</strong>ntrol key<br />

The C key is for sensor/actuator<br />

identification, set-up of the<br />

system and acknowledgement.<br />

Alarm LED<br />

The LED signals alarms or<br />

configuration changes.<br />

Link/Traffic LED<br />

The LED signals the status<br />

of the network interface<br />

10BaseT/100BaseT.<br />

RS 232 interface RJ 10<br />

For programming via the serial<br />

PC interface.<br />

LEDs for channels of sensor<br />

units<br />

The LEDs indicate the status<br />

of the attached sensor units.<br />

Acoustic alarm<br />

There is an acoustic alarm<br />

signalling device integrated<br />

into the PU II plus.<br />

Mounting attachment<br />

For attachment with individual<br />

bracket DK 7320.450 or 1 U<br />

mounting units DK 7320.440.<br />

8 Inputs for sensor unit RJ 45<br />

Up to 4 sensor units may be connected to the<br />

PU II plus via the 4 inputs. The sensor units<br />

determine the function of the PU II plus.<br />

There is a choice of 14 sensor units:<br />

– I/O Unit DK 7320.210<br />

– Access Unit DK 7320.220<br />

– Climate Unit DK 7320.230<br />

– Wireless I/O Unit DK 7320.240<br />

– FCS DK 7320.810/DK 7858.488<br />

– RTT I/O Unit DK 3124.200<br />

– RLCP DK 3301.230/.420<br />

– Active PSM DK 7856.200/.201<br />

– RPCU DK 7200.001<br />

– MPS Monitoring<br />

<strong>Co</strong>nnection cable DK 7320.470.<br />

9 Power-I 2 C bus RJ 45<br />

Up to 2 voltage extension units DK 7200.520<br />

may be connected via the power I 2 C bus.<br />

Up to three AC voltages may be monitored<br />

with every extension unit. <strong>Co</strong>nnection cable<br />

DK 7320.470.<br />

10 Alarm relay RJ 12/RS232<br />

The upper RJ 12 jack provides a change-over<br />

contact from the PU II plus alarm relay.<br />

<strong>Co</strong>nnection cable DK 7200.430.<br />

The lower RJ 12 jack provides a serial interface<br />

(display unit/GSM module/ISDN unit/<br />

Legic transponder handle/analog modem).<br />

11 Ethernet 10/100BaseT RJ 45<br />

Integral Ethernet interface to IEEE 802.3 via<br />

10/100BaseT full-duplex 10/100 Mbit/s.<br />

12 Power supply<br />

The rated voltage for the PU II plus is<br />

24 V DC. There is a choice of power packs<br />

with varying primary voltages. AC power pack<br />

DK 7320.425.<br />

Model No. DK 7320.101<br />

W x H x D mm 136 x 44 (1 U) x 129<br />

Network<br />

interface<br />

Protocols<br />

Rated voltage<br />

Serial interfaces<br />

Ports for<br />

sensor units<br />

Bus system<br />

Alarm relay<br />

output<br />

Audio display<br />

Time function<br />

Temperature<br />

application range<br />

Humidity<br />

application range<br />

IP protection<br />

category<br />

Also required:<br />

Ethernet to IEEE 802.3<br />

via 10/100BaseT full-duplex,<br />

10/100 Mbit/s<br />

TCP/IPv4, TCP/IPv6, SNMPv1,<br />

SNMPv3, Telnet, SSH, FTP,<br />

SFTP with SSH, HTTP,<br />

HTTPS with SSL, NTP, DHCP, PPP,<br />

SMTP<br />

24 V DC<br />

RS232<br />

4 jacks RJ 45, shielded<br />

Power I 2 C for extension unit<br />

voltage AC DK 7200.520<br />

Change-over contact<br />

max. 24 V DC 500 mA<br />

Piezo signal generator<br />

Real-time clock<br />

+5°C to +45°C<br />

5% to 95% relative humidity,<br />

non-condensing<br />

IP 40 to EN 60 529<br />

Power pack DK 7320.425,<br />

connection cable DK 7200.210,<br />

programming cable DK 7200.221.<br />

Optional:<br />

1 U mounting unit DK 7320.440,<br />

single cover DK 7320.441.<br />

34 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Security


Security<br />

Basic CMC plus monitoring system<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

C<br />

IOIOI<br />

CMC-TC<br />

Basic CMC plus<br />

1 2 3 4<br />

5 6<br />

1 2<br />

1<br />

P-I 2 C<br />

3 4<br />

IOIOI<br />

Power<br />

24 V DC<br />

max. 2 A<br />

11 10 9 8 7<br />

<strong>Co</strong>ntrol key<br />

The C key is for sensor/actuator<br />

identification, set-up of the<br />

system and acknowledgement.<br />

Alarm LED<br />

The LED signals alarms or<br />

configuration changes.<br />

Link/Traffic LED<br />

The LED signals the status<br />

of the network interface<br />

10BaseT/100BaseT.<br />

RS 232 interface RJ 10<br />

For programming via the serial<br />

PC interface.<br />

Acoustic alarm<br />

There is an acoustic alarm<br />

signalling device integrated<br />

into the Basic CMC plus.<br />

Mounting attachment<br />

For attachment with individual<br />

bracket DK 7320.450 or 1 U<br />

mounting units DK 7320.440.<br />

Power supply<br />

The rated voltage of the Basic<br />

CMC plus is 24 V DC. There<br />

is a choice of power packs<br />

with varying primary voltages.<br />

AC power pack DK 7320.425.<br />

Ethernet 10/100BaseT RJ 45<br />

Integral Ethernet interface to<br />

IEEE 802.3 via 10/100BaseT<br />

full-duplex 10/100 Mbit/s.<br />

Basic CMC plus<br />

The Basic CMC plus is the entry-level module for<br />

small monitoring applications; a maximum of<br />

4 sensors may be connected to the system. Three<br />

voltages may optionally be monitored via module<br />

DK 7200.520. The system has a network interface<br />

and a user-friendly web operator interface. The<br />

Basic CMC plus supports protocols IPv4 and<br />

IPv6, making it suitable for current and future IPv6<br />

TCP-IP networks.<br />

Benefits:<br />

● There are 18 plug & play sensors available<br />

to choose from<br />

● TCP/IP, SNMP network connection<br />

● Integral web server for configuration<br />

● Automatic menu setting<br />

● Simple installation based on the plug & play<br />

system<br />

● Monitoring of sensor connection<br />

● Alarm recording in case of network failure<br />

● Built-in real-time clock with NTP<br />

● May be used via power pack for 100 – 240 V AC<br />

or 48 V DC<br />

9 Alarm relay RJ 12/RS232<br />

The upper RJ 12 jack provides a change-over<br />

contact from the Basic CMC plus alarm relay.<br />

<strong>Co</strong>nnection cable DK 7200.430.<br />

The lower RJ 12 jack provides a serial interface<br />

(display unit/GSM module/ISDN unit).<br />

10 Power-I 2 C bus RJ 45<br />

Up to 2 voltage extension units DK 7200.520<br />

may be connected via the power I 2 C bus.<br />

Up to three AC voltages may be monitored<br />

with every extension unit.<br />

<strong>Co</strong>nnection cable DK 7320.470.<br />

11 Inputs for a maximum of 4 sensors<br />

Up to 4 sensors may be connected via the<br />

4 inputs. There is a choice of 18 different<br />

sensor/actuator types.<br />

Sensors/actuators<br />

Max.<br />

Model No.<br />

DK<br />

Temperature sensor 4 7320.500<br />

Humidity sensor 4 7320.510<br />

Analog sensor input module<br />

“4 – 20 mA”<br />

4 7320.520<br />

Access sensor 1) 4 x 5 7320.530<br />

Vandalism sensor 4 7320.540<br />

Acoustic sensor 4 7320.640<br />

Airflow monitor 4 7320.550<br />

Smoke alarm 4 7320.560<br />

Motion sensor 4 7320.570<br />

Digital input module 4 7320.580<br />

Digital relay output module 4 7320.590<br />

Voltage monitor 4 7320.600<br />

Voltage monitor<br />

with 10 A switch output<br />

2 – 4 7320.610<br />

Voltage monitor<br />

with 16 A switch output<br />

2 – 4 7320.611<br />

48 V voltage monitor 4 7320.620<br />

Leak sensor 4 7320.630<br />

Leak sensor, 15 m 4 7320.631<br />

Automatic Door <strong>Co</strong>ntrol Unit 4 7320.790<br />

1) Up to a maximum of 5 sensors may be connected<br />

in series.<br />

Interface to user:<br />

The Basic CMC plus can be incorporated directly<br />

into the user network via 10/100BaseT. The Basic<br />

CMC plus can also be linked to the master<br />

DK 7320.005 via this interface (TCP/IP, SNMP).<br />

Interface to the sensors/actuators:<br />

The Basic CMC plus provides 4 open ports for<br />

sensors. There is a choice of 18 sensors with<br />

different functions. In this way, the monitoring<br />

functions may be freely combined.<br />

Fast, easy programming and installation:<br />

The sensors/actuators are set up via an automatic<br />

electronic ID system.<br />

Installation is via a flexible plug & play system.<br />

This eliminates the need for time-consuming<br />

programming and wiring.<br />

Power supply:<br />

Power is supplied centrally via a power pack in<br />

the Basic CMC plus. This supplies the connected<br />

sensors. There is a choice of two input voltages<br />

(AC power pack DK 7320.425 and DC power<br />

pack DK 7320.435).<br />

Model No. DK 7320.112<br />

W x H x D mm 136 x 44 (1 U) x 129<br />

Network<br />

interface<br />

Protocols<br />

Rated voltage<br />

Serial interfaces<br />

Ports for sensors<br />

Bus system<br />

Alarm relay<br />

output<br />

Audio display<br />

Time function<br />

Temperature<br />

application range<br />

Humidity<br />

application range<br />

IP protection<br />

category<br />

Note:<br />

No sensor units, socket strips, access systems,<br />

PSM, climate control systems etc. may be connected<br />

to the Basic CMC plus. PU II plus,<br />

Model No. DK 7320.101, is needed in the CMC-TC<br />

system in such cases.<br />

Also required:<br />

Ethernet to IEEE 802.3<br />

via 10/100BaseT full-duplex,<br />

10/100 Mbit/s<br />

TCP/IPv4, TCP/IPv6, SNMPv1,<br />

SNMPv3, Telnet, SSH, FTP,<br />

SFTP with SSH, HTTP, HTTPS with<br />

SSL, NTP, DHCP, PPP, SMTP<br />

24 V DC<br />

RS232<br />

Max. 4 sensors<br />

Power I 2 C for extension unit<br />

voltage AC DK 7200.520<br />

Change-over contact<br />

max. 24 V DC 500 mA<br />

Piezo signal generator<br />

Real-time clock with NTP<br />

+5°C to +45°C<br />

5% to 95% relative humidity,<br />

non-condensing<br />

IP 40 to EN 60 529<br />

Power pack DK 7320.425,<br />

connection cable DK 7200.210,<br />

programming cable DK 7200.221.<br />

Optional:<br />

1 U mounting unit DK 7320.440,<br />

single cover DK 7320.441.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Security<br />

35


Security<br />

Accessory modules<br />

C<br />

CMC-TC<br />

GSM Modul<br />

1 2 3<br />

GSM Unit Quad-Band<br />

In order to configure a redundant transmission<br />

channel or if there is no LAN infrastructure available,<br />

the unit may be used for alarm forwarding.<br />

The alarm signal is designed in SMS format.<br />

The GSM Unit is connected to Processing Unit<br />

DK 7320.100/.101, Basic CMC DK 7320.111/.112<br />

or Master II DK 7320.005 via a serial interface.<br />

The power supply is likewise achieved via the<br />

connection cable. The only other thing needed to<br />

operate the module is a SIM card. These may<br />

either be “data only” cards or conventional SIM<br />

cards.<br />

The GSM Unit Quad-Band covers 4 GSM frequencies:<br />

850 MHz, 900 MHz, 1800 MHz and<br />

1900 MHz. This means that the system is also<br />

suitable for GSM applications on the American<br />

market. Up to four target call numbers may be<br />

set and allocated to the various events.<br />

Other functions, where offered by the provider:<br />

● Voice mail<br />

1 Alarm LED<br />

2 GSM LED<br />

3 Mounting fixture for DK 7320.440 or<br />

DK 7320.450<br />

GSM Unit Quad-Band<br />

Model No. DK<br />

SMS function 7320.820<br />

To activate CMC-TC switch outputs, an SMS message<br />

may be sent to the GSM unit via any standard<br />

mobile phone, so as to execute the actions via<br />

this route. The aerial included with the supply has<br />

a connection cable of 2.8 m. Voltage supply is<br />

achieved via the Processing Unit.<br />

A standard, commercially available SIM card for<br />

GSM must be provided by the customer.<br />

Note:<br />

The serial interface RS232 of the PU II may only<br />

be assigned to one accessory module.<br />

Also required:<br />

Processing Unit, DK 7320.100/DK 7320.101<br />

Basic CMC, DK 7320.111/DK 7320.112<br />

Master II, DK 7320.005<br />

IOIOI<br />

SIM<br />

Power<br />

24 V DC<br />

max. 80 mA<br />

4 5 6 7<br />

4<br />

5<br />

6<br />

7<br />

RJ 12 jack for connecting to the serial interface<br />

of the PU<br />

SIM card rack mount<br />

Aerial connection<br />

The GSM Unit Quad-Band may optionally be<br />

supplied with 24 V DC, 500 mA via this input.<br />

For applications with the PU, this is not necessary.<br />

36 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Security


Security<br />

Accessory modules<br />

<strong>Co</strong>mfort handle TS 8 CCP<br />

with master key function<br />

The handle assumes the function of a door lock<br />

and lever handle monitoring.<br />

Master key means that the handle can always be<br />

opened with the master key, independently of the<br />

control system. A semi-cylinder (lock insert, lock<br />

no. 3524 E) is supplied loose, but a semi-cylinder,<br />

40 mm overall length to DIN 18 252, may also<br />

be used.<br />

An access sensor (DK 7320.530) must be connected<br />

to the corresponding door for each handle.<br />

If the lever handle is closed, the locking mechanism<br />

integrated into the handle latches automatically.<br />

The handle may be released via the<br />

CMC-TC system in the network or via optional<br />

add-on systems, such as smartcard readers etc.<br />

The handle is locked in a de-energised manner<br />

(without electrical connection). The push-button<br />

may be depressed following electrical release and<br />

then opens the lever automatically. It must always<br />

be opened within an adjustable period of time.<br />

Opening via the key always overrides other<br />

options, i.e. the enclosure may always be opened<br />

with the key in the case of electrical locking and in<br />

the event of a power failure (emergency opening).<br />

CCP (<strong>Co</strong>ntinuous Current Possible):<br />

The handle release coil may be permanently<br />

charged with current. This makes it possible to<br />

use the “unlock” function and a longer release<br />

time of 0 – 999 seconds.<br />

Note:<br />

The handle must only be used in conjunction with<br />

a PU II DK 7320.100 (hardware V3.01) from software<br />

version 2.42.<br />

Handle system<br />

<strong>Co</strong>mfort handle TS 8<br />

with master key function<br />

To fit sensor unit:<br />

Technical specifications:<br />

Rated voltage: 24 V DC<br />

Rated current: Max. 100 mA<br />

<strong>Co</strong>nnection cable: Length 3 m, RJ 12 connector<br />

<strong>Co</strong>nnection cable:<br />

Length 2 m, RJ 12/RJ 12 connector<br />

<strong>Co</strong>upling for extension:<br />

RJ 12/RJ 12 jack<br />

Temperature application range:<br />

+5°C to +40°C<br />

Protection category:<br />

IP 40<br />

Also required:<br />

Access sensor DK 7320.530,<br />

see <strong>IT</strong> Catalogue, page 177.<br />

Model No. DK<br />

7320.721<br />

I/O Unit Access unit Climate Unit<br />

– –<br />

Spare battery<br />

Wireless sensors<br />

The battery of the wireless sensors is designed for<br />

a battery service life of up to 5 years. After this<br />

period, a new battery may be inserted. Essentially,<br />

the battery is monitored by the system, and<br />

notifies when a replacement is needed. There are<br />

various applications in which the battery service<br />

life is shortened (constant operation of the measurement<br />

system, poor or no radio connection,<br />

operating temperature limit range).<br />

The battery may be used for the following WL<br />

products:<br />

Spare battery<br />

Model No. DK<br />

for wireless sensors 7320.248<br />

Extended delivery times.<br />

Technical specifications:<br />

Type: Lithium primary cell<br />

Rated voltage: 3.6 V DC<br />

Temperature application range: –25°C to +65°C<br />

Wireless sensors<br />

Model No. DK<br />

Temperature sensor 7320.505<br />

Humidity sensor 7320.515<br />

Access sensor 7320.535<br />

Digital input 7320.585<br />

Measurement system 7320.242<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Security<br />

37


Security<br />

Rack extinguisher system<br />

Rack extinguisher system<br />

DET-AC Plus, 1 U<br />

with integral early fire detection<br />

D = 620 mm<br />

This compact rack extinguisher system DET-AC<br />

Plus short (Detection Active Plus) is designed for<br />

use in the <strong>Rittal</strong> <strong>IT</strong> rack, fitted in the 482.6 mm<br />

(19˝) level. The system is equipped with a 2-stage<br />

smoke analysis extractor system. A bayed rack<br />

may optionally be included in the monitoring and<br />

extinguisher system. The eco-friendly, non-toxic<br />

Novec TM1) 1230 is used as the extinguisher medium,<br />

which means that this extinguisher system<br />

is suitable for universal use. Sensitive hardware<br />

such as servers, storage and switches are not<br />

impaired by the extinguisher medium. Thanks to<br />

the extremely sensitive detection of smoke, even<br />

in racks with a high level of climate control (airflow<br />

speed), this ensures that there is plenty of<br />

time to forward an alarm message either acoustically,<br />

optically via the LC display on the enclosure<br />

front, or by connecting the integral floating contacts<br />

to the building management system or fire<br />

alarm centre and to the <strong>Rittal</strong> monitoring system<br />

CMC-TC. When opening an enclosure door, activation<br />

of the extinguisher system is blocked by<br />

the two access sensors (door monitoring).<br />

In order to ensure that proper functioning of the system<br />

is maintained even in the event of a power failure,<br />

an emergency back-up power supply with a<br />

stored energy time of 4 hours is integrated into the<br />

system. The system can also be supplied purely as<br />

an early fire detection system (DET-AC Plus early fire<br />

detection) without the extinguisher medium tank.<br />

1)<br />

Novec TM is a registered trademark of 3M.<br />

Technical specifications:<br />

DET-AC Plus short extinguisher system<br />

DK 7338.110<br />

Installation dimensions (W x H x D):<br />

482.6 mm (19˝) x 1 U x 620 mm<br />

Weight: 15 kg (incl. extinguisher and propellant<br />

gas cartridge)<br />

Operating temperature: +10°C to +35°C<br />

Protection category: IP 20 to EN 60 529<br />

Admissible protection volume:<br />

Max. 3 m 3 (with sealed enclosures)<br />

Max. DET-AC slave units DK 7338.300 that may<br />

be connected: 4<br />

Max. number of enclosures monitored:<br />

5 (volume-dependent)<br />

Extinguisher: 3.2 kg Novec TM 1230<br />

Sensors: 2 scattered-light sensors with different<br />

sensitivities<br />

Manual trigger input: Yes<br />

Extinguisher blocking input: Yes, via door contact<br />

Outputs for CMC-TC (I/O Unit): Pre-alarm, fire,<br />

extinguishing, collective fault<br />

Emergency power supply (rechargeable battery):<br />

Approx. 4 h<br />

Operating voltage: 100/240 V AC, 50/60 Hz<br />

Technical specifications:<br />

DET-AC Plus fire early detection DK 7338.200<br />

Installation dimensions (W x H x D):<br />

482.6 mm (19˝) x 1 U x 480 mm<br />

Weight: 8 kg<br />

Operating temperature: +10°C to +35°C<br />

Protection category: IP 20 to EN 60 529<br />

Max. DET-AC slave units DK 7338.300 that may<br />

be connected: 5<br />

Max. number of enclosures monitored:<br />

5 (volume-dependent)<br />

Sensors: 2 scattered-light sensors with different<br />

sensitivities<br />

Manual trigger input: Yes<br />

Extinguisher blocking input: Yes, via door contact<br />

Outputs for CMC-TC (I/O Unit): Pre-alarm, fire,<br />

extinguishing, collective fault<br />

Emergency power supply (rechargeable battery):<br />

Approx. 4 h<br />

Operating voltage: 100/240 V AC, 50/60 Hz<br />

Technical specifications:<br />

DET-AC Plus slave unit DK 7338.300<br />

Installation dimensions (W x H x D):<br />

482.6 mm (19˝) x 1 U x 530 mm<br />

Weight: 17 kg (incl. extinguisher and propellant<br />

gas cartridge)<br />

Operating temperature: +10°C to +35°C<br />

Protection category: IP 20 to EN 60 529<br />

Admissible protection volume:<br />

Max. 3 m 3 (with sealed enclosures)<br />

Extinguisher: 2.9 kg Novec TM 1230<br />

Operating voltage: 24 V DC<br />

Early smoke detection:<br />

Thanks to the two highly sensitive optical sensors,<br />

minute particles of smoke may be detected<br />

even in the early stages of a fire (pyrolysis phase)<br />

via the active smoke extraction. If the 1st alarm<br />

detects smoke aerosols, a pre-alarm is triggered,<br />

and if the 2nd alarm likewise detects smoke, the<br />

extinguisher system is activated. This prevents<br />

major fires from developing.<br />

Rack requirements:<br />

As a general principle, the racks must meet protection<br />

category IP 55, i.e. with sealed doors and<br />

screw-fastened side panels. Use of an air/water<br />

heat exchanger (LCP) is supported. All cable<br />

entry areas must be sealed.<br />

Optional smoke analysis, extension for bayed<br />

racks:<br />

The basic DET-AC Plus short is designed for a<br />

single rack, but neighbouring enclosures may<br />

also be incorporated via an additional pipe kit,<br />

provided the total interior enclosure volume to be<br />

extinguished does not exceed 3 m 3 . Several extinguisher<br />

systems may also be linked together in<br />

the bayed enclosure suites, so that all systems<br />

may be activated jointly.<br />

Automatic system deactivation<br />

(compulsory deactivation):<br />

In conjunction with the <strong>Rittal</strong> enclosure monitoring<br />

system CMC-TC plus suitable switchable <strong>Rittal</strong><br />

socket strips (Power System Module PSM/Power<br />

<strong>Co</strong>ntrol Unit PCU with active current measurement,<br />

display and switching options), in the event<br />

of an alarm, compulsory deactivation of the components<br />

installed in the rack may be triggered.<br />

This ensures that the servers are protected from<br />

further destruction.<br />

The alarms (pre-alarm, main alarm) may be transmitted<br />

via any given IP networks and processed<br />

in corresponding monitoring programs. The extinguisher<br />

system is supplied complete with mounting<br />

accessories.<br />

38 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Security


Security<br />

Rack extinguisher system<br />

1 2 3 4 5 6<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

Extinguisher tank with fill level monitoring,<br />

overpressure fuse and electrical tripping device<br />

Propellant gas cartridge<br />

Fire sensors<br />

<strong>Co</strong>nnections for CMC-TC and alarm contacts<br />

Mainboard<br />

<strong>Co</strong>nnections for extractor and waste air pipe<br />

Front panel with display and operating panel<br />

Extinguisher nozzle<br />

Emergency power supply (rechargeable batteries)<br />

Power pack<br />

Extraction fan<br />

7 8<br />

9 10 11<br />

Rack extinguisher system<br />

DET-AC Plus short, 1 U<br />

The system is comprised of<br />

4 products:<br />

● The DET-AC Plus short extinguisher<br />

system with integral<br />

early fire detection and extinguisher<br />

gas, with a short<br />

enclosure depth of 620 mm.<br />

This means that enclosures<br />

with depths of 800 – 1200 mm<br />

may be configured. For enclosures<br />

with 800 mm depth the<br />

front 482.6 mm (19˝) level<br />

must be attached to the front<br />

of the enclosure, as space at<br />

the back is needed for pipework.<br />

● The early fire detection system<br />

DET-AC Plus short is for<br />

detection only.<br />

● The slave unit<br />

DET-AC Plus short is an extinguisher<br />

gas extension only.<br />

● The DET-AC Plus short piping<br />

kit is for detection extension<br />

for one rack.<br />

Supply includes:<br />

Extinguisher system kit<br />

DET-AC Plus short<br />

DK 7338.110:<br />

Main product<br />

Extinguisher system<br />

DET-AC Plus short,<br />

instructions,<br />

flexible 482.6 mm (19˝) attachment<br />

at the rear of the enclosure,<br />

pipe kit for air extraction,<br />

single application, may be<br />

dismantled,<br />

RJ 12 cable 1 m for attaching<br />

to CMC-TC.<br />

Fire early detection kit<br />

DET-AC Plus<br />

DK 7338.200:<br />

Main product<br />

Fire early detection<br />

DET-AC Plus,<br />

instructions,<br />

depth-variable slide rail,<br />

piping kit for air extraction,<br />

single application, may be<br />

dismantled,<br />

RJ 12 cable 1 m for connecting<br />

to CMC-TC.<br />

Slave unit kit<br />

DET-AC Plus<br />

DK 7338.300:<br />

Main product<br />

Slave unit<br />

DET-AC Plus,<br />

instructions,<br />

bus cable kit for 24 V DC and<br />

for communication,<br />

depth-variable slide rail,<br />

piping kit for air extraction,<br />

slave application, may be<br />

dismantled,<br />

RJ 12 cable 1 m for connecting<br />

to CMC-TC.<br />

Piping kit<br />

DET-AC Plus<br />

for slave application<br />

DK 7338.310:<br />

Piping kit for air extraction,<br />

slave application, may be<br />

dismantled,<br />

with second T-piece.<br />

Description of main products Packs of Model No. DK<br />

Kit extinguisher system DET-AC Plus short incl. one piping kit<br />

for single applications<br />

1 7338.110 1)<br />

Kit early fire detection DET-AC Plus short incl. one piping kit<br />

for single applications<br />

1 7338.200 1)<br />

Description of extensions<br />

Kit slave unit DET-AC Plus incl. one piping kit<br />

for single applications<br />

1 7338.300 1)<br />

Kit piping kit DET-AC Plus<br />

for slave applications<br />

1 7338.310 1)<br />

Accessories required for main products<br />

Access sensor to block the extinguisher process with open doors 1 7320.530<br />

<strong>Co</strong>nnection cable D/F/B earthing-pin, for power supply 1 7200.210 2)<br />

Recommended accessories<br />

The CMC-TC system for alarm forwarding via I/O unit, PU II, etc. 1 7320.210 3)<br />

1) Delivery times available on request.<br />

2) For country-specific connection cables, see <strong>IT</strong> Catalogue, page 167.<br />

3) Note: a complete CMC-TC system must be selected.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Security<br />

39


Security<br />

Rack extinguisher system<br />

1<br />

2<br />

3<br />

Examples of baying systems<br />

A maximum of 5 bayed enclosures may be<br />

detected with one system; the DET-AC Plus short<br />

extinguisher system should be used here, and all<br />

other enclosures connected to the integral extractor<br />

unit using the DET-AC Plus piping kit. Regarding<br />

volume, all other enclosures should each be<br />

allocated one DET-AC Plus slave unit. The total<br />

volume of the bayed enclosure suite must always<br />

be taken into account. The bayed enclosures<br />

must be consistently interconnected in order to<br />

ensure air exchange. All slave units must be connected<br />

to the extinguisher system with detection<br />

via a bus. This controls simultaneous activation of<br />

the extinguisher gas tank.<br />

1<br />

2<br />

3<br />

4<br />

Extinguishing 5 bayed enclosures:<br />

One extinguisher system, 4 slave units,<br />

one connection cable and 10 access sensors<br />

are needed.<br />

Extinguishing 5 bayed enclosures<br />

with 4 LCP:<br />

One extinguisher system, 4 slave units,<br />

one connection cable and 18 access sensors<br />

are needed.<br />

5 bayed enclosures, detection only,<br />

no extinguishing:<br />

One early fire detection system, 4 piping kits<br />

and one connection cable are required.<br />

Extinguishing 2 enclosures<br />

with a depth of 800 mm:<br />

No extinguisher system is used, since the<br />

combination of early fire detection and slave<br />

units has a smaller depth. One early fire<br />

detection system, 2 slave units, one connection<br />

cable and 4 access sensors are needed.<br />

Note:<br />

The extinguisher system must be installed and<br />

maintained by qualified experts. <strong>Rittal</strong> is happy to<br />

offer such a service.<br />

When baying several different <strong>IT</strong> racks together, a<br />

combined enclosure interior volume of 3 m 3 must<br />

not be exceeded!<br />

Enclosure interior volume of popular <strong>Rittal</strong> <strong>IT</strong> racks<br />

Width<br />

mm<br />

Height<br />

mm<br />

Depth<br />

mm<br />

Enclosure interior volume<br />

per rack/m 3<br />

300 2000 1000 0.6<br />

300 2000 1200 0.72<br />

600 2000 1000 1.2<br />

600 2000 1200 1.44<br />

600 2200 1000 1.32<br />

600 2200 1200 1.584<br />

800 2000 1000 1.6<br />

800 2000 1200 1.92<br />

800 2200 1000 1.76<br />

800 2200 1200 2.112<br />

Extinguisher system<br />

4<br />

Slave unit<br />

Early fire detection<br />

Extractor pipes<br />

40 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Security


Security<br />

Automatic door opener<br />

Automatic Door <strong>Co</strong>ntrol Unit<br />

● For automatic opening of the rack door in case<br />

of fire or in case of a cooling failure in sealed<br />

rack systems in conjunction with the <strong>Rittal</strong><br />

CMC-TC system.<br />

● Activation of up to 4 Automatic Door Kits<br />

(DK 7320.791/DK 7320.792) is possible. There<br />

is 1 control channel available per 2 Automatic<br />

Door Kits (e.g. front and rear door). There is<br />

optionally a normally-closed contact integrated<br />

for each door output, which is used to connect<br />

the automatic door switch (DK 7320.793) or<br />

a customer-specific system (e.g. room extinguisher<br />

system).<br />

● For mounting in a 1 U component support<br />

DK 7320.440 or with the individual mounting<br />

unit DK 7320.450.<br />

Model No. DK 7320.790<br />

W x H x D mm 136 x 44 (1 U) x 129<br />

Rated voltage<br />

Door outputs<br />

Ports for<br />

CMC-TC system<br />

Normally closed<br />

contacts<br />

Temperature<br />

application range<br />

Humidity<br />

application range<br />

IP protection<br />

category<br />

24 V DC<br />

4 x 24 V DC, 400 mA<br />

2 x RJ 12<br />

<strong>Co</strong>nnection must be designed for<br />

30 V DC, 1 A<br />

+5°C to +45°C<br />

5% to 95% relative humidity,<br />

non-condensing<br />

IP 40 to EN 60 529<br />

1<br />

2<br />

3<br />

4<br />

3<br />

2<br />

LAN<br />

1<br />

4<br />

LCP Plus<br />

Automatic Door <strong>Co</strong>ntrol Unit<br />

I/O unit<br />

Processing Unit PU II<br />

Basic CMC<br />

To fit sensor unit<br />

LCP Plus Basic CMC I/O Unit Access Unit Climate Unit<br />

– –<br />

Also required:<br />

Designation<br />

No. of Model No.<br />

packs of DK<br />

Automatic Door Kit, 1-piece door Max. 4 7320.791<br />

Automatic Door Kit, 2-piece door Max. 4 7320.792<br />

AC power pack 230 V 1 7320.425 1)<br />

DC power pack 48 V 1 7320.435<br />

<strong>Co</strong>nnection cable D/F/B 1 7200.210<br />

<strong>Co</strong>nnection cable GB 1 7200.211<br />

<strong>Co</strong>nnection cable CH 1 7200.213<br />

<strong>Co</strong>nnection cable USA/CDN 1 7200.214<br />

<strong>Co</strong>nnection cable C13 1 7200.215<br />

1) 1 connection cable is required for 1 power pack.<br />

Accessories:<br />

Designation<br />

No. of Model No.<br />

packs of DK<br />

Automatic door switch Max. 4 7320.793<br />

1 U mounting unit 1 7320.440<br />

Mounting module CMC 1 7320.450<br />

I/O unit 1 7320.210 2)<br />

Basic CMC 1 7320.111<br />

LCP Plus 1 3301.480 3)<br />

2) A complete CMC-TC system is required to operate<br />

the I/O unit.<br />

3) See page 28.<br />

Automatic Door Kit<br />

● Equips a standard door for the Automatic Door<br />

Opening System for automatic opening of the<br />

rack door in case of fire or in case of a cooling<br />

failure.<br />

● The Automatic Door Kit operates with a gas<br />

pressure damper system, allowing the door to<br />

be opened in any emergency situation. The<br />

doors are kept closed by a magnet system,<br />

which unlike mechanical lock systems will<br />

release the door in every instance.<br />

● The Automatic Door Kit is connected and activated<br />

using the related control unit (Automatic<br />

Door <strong>Co</strong>ntrol Unit DK 7320.790).<br />

● Automatic Door Kit, 1-piece. The door<br />

(DK 7320.791) is compatible with TS 8 glazed<br />

and sheet steel doors<br />

● Automatic Door Kit, 2-piece. The door<br />

(DK 7320.792) is compatible with TS 8 sheet<br />

steel glazed doors, vertically divided, and sheet<br />

steel doors, vertically divided. The tubular door<br />

frame may need to be ordered separately.<br />

Version<br />

for<br />

Packs of Model No. DK<br />

1-piece door 1 7320.791<br />

2-piece door 1 7320.792<br />

Supply includes:<br />

Gas pressure damper, cable harness,<br />

magnetic lock,<br />

assembly parts.<br />

Automatic door switch<br />

Switch for connecting to the normally closed<br />

contacts of the Automatic Door <strong>Co</strong>ntrol Unit<br />

(DK 7320.790) for manual door opening.<br />

It is mounted on the 25 mm pitch pattern of the<br />

TS 8 frame section.<br />

Technical specifications:<br />

Installation Ø 16.2 mm, 250 V/2 A<br />

Packs of<br />

Model No. DK<br />

1 7320.793<br />

Supply includes:<br />

3 m connection cable, mounting brackets,<br />

including assembly parts.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Security<br />

41


Monitoring<br />

Dynamic Rack <strong>Co</strong>ntrol<br />

<strong>Co</strong>mponent recognition, consolidation and optimisation<br />

with an innovative module of the comprehensive<br />

Data Centre Management system.<br />

Radio Frequency Identification, or RFID, is a globally<br />

standardised technology for the contactless detection<br />

of objects in the room. An RFID system is always comprised<br />

of 2 components: a reader with an aerial (RFID<br />

mounting frame with reader), and a small microchip<br />

with an aerial coil on a substrate material (RFID tag).<br />

<strong>Rittal</strong> uses this technology directly inside the rack to<br />

log component population of the 482.6 mm (19˝) level<br />

completely contactlessly and in real time. In this way,<br />

a current overview of the components installed in the<br />

racks, separated according to device category, power<br />

consumption or form factor, is possible at any time.<br />

Visualisation in the web browser<br />

Basic data and power budget of an individual<br />

rack configuration.<br />

Extended management information.<br />

Master data record of a 482.6 mm (19˝)<br />

component.<br />

42 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Monitoring


Monitoring<br />

Dynamic Rack <strong>Co</strong>ntrol<br />

RFID mounting frame<br />

for TS 8<br />

With integral RFID reader (aerial) to accommodate<br />

the 482.6 mm (19˝) built-in components.<br />

The mounting frame may be depth-variably<br />

secured in the TS 8 and is used to structure the<br />

front 482.6 mm (19˝) mounting level.<br />

Position detection of the components is accurate<br />

to within 1/3 U, therefore there are 3 aerial elements<br />

and signalling LEDs integrated into each U.<br />

The installation position of the components is<br />

correctly recognised even if they are not located<br />

precisely in the height pitch pattern. Reading and<br />

writing of the RFID tags is likewise signalled by<br />

one LED in each case.<br />

Additionally, a matching mounting frame without<br />

RFID reader (see ordering table) is required to<br />

emulate the rear mounting level.<br />

Width<br />

mm<br />

For<br />

TS 8<br />

Height<br />

mm<br />

U<br />

RFID<br />

mounting<br />

frame, front<br />

Mounting<br />

frame, rear<br />

Model No. DK Model No. DK<br />

600 2000 42 7890.206 7856.719<br />

800 2000 42 7890.208 7856.731<br />

600 2200 47 7890.226 7856.722<br />

800 2200 47 7890.228 7856.734<br />

Further dimensions available on request.<br />

Load capacity:<br />

Max. 1000 kg static load with even distribution<br />

across two 482.6 mm (19˝) mounting levels.<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

RFID tags<br />

1 RFID tag is required for each component.<br />

Each tag has a “Unique ID” (UID, not sequential),<br />

which cannot be altered, data is stored on the tag<br />

in conformity with ISO 15693. The tags are unwritten<br />

in their delivered state. The tag is stuck to the<br />

inside right of the 482.6 mm (19˝) mounting<br />

bracket with an adhesive surface. The component<br />

is later screw-fastened to the 482.6 mm (19˝)<br />

level, including the tag.<br />

Passive, writable RFID tag (13.56 MHz)<br />

Packs of<br />

Model No. DK<br />

20 7890.020<br />

Also required:<br />

RFID controller, see below and<br />

CMC-TC Processing Unit II 1)<br />

(firmware from Version 2.70), DK 7320.100,<br />

wide-range power pack (sec. 24 V DC),<br />

DK 7320.425,<br />

1 U mounting unit, DK 7320.440,<br />

connection cable (Cat 5), DK 7320.472,<br />

CMC-TC programming cable, DK 7200.221,<br />

connection cable (DE) 230 V AC, DK 7200.210,<br />

see <strong>IT</strong> Catalogue from page 158.<br />

1)<br />

Sufficient for 1 – 4 racks with RFID mounting<br />

frame.<br />

RFID controller<br />

This controller connects the RFID reader (aerial)<br />

of the 482.6 mm (19˝) mounting frame to the<br />

CMC-TC system. Additionally, at a later date, an<br />

optional RFID floor reader may be connected to<br />

this controller for precise position-finding of the<br />

rack in the data centre.<br />

One RFID controller is required per rack.<br />

Enclosure dimensions W x H x D:<br />

136 x 44 (1 U) x 129 mm<br />

Material:<br />

Plastic<br />

Rated voltage:<br />

24 V DC<br />

<strong>Co</strong>nnections:<br />

RJ 45 socket (connection to CMC-TC)<br />

2 x Mini-DIN (connection of RFID frame & floor<br />

reader)<br />

Packs of<br />

Model No. DK<br />

1 7890.500<br />

Also required:<br />

Mounting module CMC, DK 7320.450,<br />

see <strong>IT</strong> Catalogue, page 170,<br />

Cat 5 patch cable,<br />

see <strong>IT</strong> Catalogue, page 169.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Monitoring<br />

43


Monitoring<br />

RiZone – Data Centre Management Software<br />

What can the RiZone Data Centre Management Software do?<br />

1. RiZone is the management platform for all components in the data centre<br />

infrastructure.<br />

● Monitoring of redundant data centres (up to Tier IV).<br />

● Fast configuration, automatic detection of all active RimatriX5 components.<br />

● Precise adaptation to requirements, thanks to a modular licence model.<br />

● Efficient administration of the physical infrastructure (from the “single-enclosure<br />

data centre” through to the “maxi-data centre”, thanks to a high level of flexibility<br />

and availability.<br />

2. RiZone can communicate with a server management system (e.g. System<br />

Center Operations Manager from Microsoft) and exert direct influence over the<br />

availability of individual applications.<br />

3. RiZone supports the protocols SNMP and BACnet for connecting and monitoring<br />

all equipment in the <strong>IT</strong> and building structure.<br />

At last, “isolated thinking” in <strong>IT</strong> and building management is a thing of the past.<br />

RiZone is modular and scalable –<br />

for small companies through to<br />

large data centres<br />

RiZone is used for administration,<br />

monitoring and control: Access, climate<br />

control, power supply, security.<br />

Be it an individual rack, a data centre,<br />

or a company's entire <strong>IT</strong> system.<br />

44 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Monitoring


Monitoring<br />

RiZone – Data Centre Management Software<br />

Why choose <strong>Rittal</strong> RiZone?<br />

For the first time, RiZone forges a bridge between the two worlds of <strong>IT</strong> and<br />

building infrastructure.<br />

By fusing these two specialist fields, it is possible to<br />

● Optimise availability<br />

● Simplify by reducing complexity and<br />

● Boost the efficiency of the data centre.<br />

The high availability demands of data centre users necessitates a comprehensive,<br />

efficient security management sytsem. The pre-requisite for this is the monitoring of all<br />

components and parameters of the building, server room and data centre which are<br />

relevant for security and availability.<br />

The brand new feature in RiZone is the implementation of all messages, sensor values<br />

and actuators in the <strong>IT</strong> infrastructure and server environment into a plausible message<br />

chain. The formulaic correlation in RiZone Editor transforms individual warnings, data or<br />

signals into logical information and actions, for absolute protection of the data centre’s<br />

availability.<br />

RiZone – From monitoring,<br />

to administration, to response<br />

With important additional functions,<br />

RiZone is the successor to the<br />

RiWatch<strong>IT</strong> software.<br />

The decisive factor is the opportunity<br />

to create your own mathematical formulae<br />

for self-defined control circuits<br />

with RiZone.<br />

RiZone – the data centre management platform<br />

supports standardised protocols<br />

The integration of RiZone into a management environment<br />

occurs with the support of SNMP. RiZone<br />

offers the option of using the <strong>IT</strong> management protocol<br />

to forward messages from RiZone.<br />

On the active component side, RiZone supports<br />

SNMP and BACnet. RiZone is capable of interpreting<br />

any MIB.<br />

RiZone teams up with Microsoft<br />

SCOM (System Center Operations<br />

Manager)<br />

Management Pack, a RiZone module,<br />

allows the optimum integration of<br />

RiZone into the System Center Operations<br />

Manager from Microsoft.<br />

This enables bidirectional interaction<br />

between servers (application level)<br />

and the data centre infrastructure.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Monitoring<br />

45


Monitoring<br />

RiZone – Data Centre Management Software<br />

Efficiency example<br />

To correspond to the power consumption<br />

of your data centre, the<br />

cooling output must be designed<br />

for maximum performance in<br />

unfavourable ambient temperatures.<br />

As this diagram of weekly operation<br />

shows, unless properly managed,<br />

a typical cooling system<br />

is overdimensioned most of the<br />

time.<br />

Here, RiZone saves energy by<br />

intelligently adapting the cooling<br />

output to the power consumption,<br />

airflow and ambient temperature.<br />

kW<br />

MON TUE WED THU FRI SAT SUN<br />

Sub-optimum cooling output Optimum cooling output Heat load (<strong>IT</strong> load)<br />

What does the RiZone Management Pack do?<br />

1. The Microsoft System Center Operations Manager shows the same view of the <strong>IT</strong> infrastructure as <strong>Rittal</strong> RiZone<br />

2. All important alarms and parameters from the <strong>IT</strong> infrastructure are depicted in the interface of the Microsoft System<br />

Center Operation<br />

● Security information<br />

● <strong>Co</strong>nsumption figures<br />

● Efficiency calculations<br />

● Detailed informationen via RiZone activation from within the System Center Operations Manager<br />

3. Holistic optimisation (server and infrastructure) of the data centre with regard to<br />

● Energy efficiency<br />

● Message chains<br />

● Availability/security<br />

46 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Monitoring


Monitoring<br />

RiZone – Data Centre Management Software, licence models<br />

RiZone Appliance Standard<br />

RiZone is supplied as an appliance or a software<br />

appliance.<br />

As an appliance, RiZone is supplied with global<br />

support, installed on a powerful server. The software<br />

appliance is available as a virtual server<br />

which can easily be used on existing hardware<br />

in the data centre.<br />

Version<br />

Model No. DK<br />

Appliance 7990.001<br />

Software Appliance 7990.003<br />

Also required:<br />

RiZone Appliance licence according to the<br />

number of IP nodes available.<br />

RiZone Appliance<br />

High-MTBF<br />

In addition to the standard version, the high-MBTF<br />

version scales up to Tier IV availability as per the<br />

definition of the Uptime Institute.<br />

RiZone is supplied as an appliance or a software<br />

appliance.<br />

As an appliance, RiZone is supplied with global<br />

support, installed on a powerful server. The software<br />

appliance is available as a virtual server<br />

which can easily be used on existing hardware in<br />

the data centre.<br />

Version<br />

Model No. DK<br />

Appliance 7990.002<br />

Software Appliance 7990.004<br />

Also required:<br />

RiZone Appliance licence according to the<br />

number of IP nodes available.<br />

RiZone Appliance licence<br />

The flexible RiZone licence model allows optimum<br />

adaptation to any project size, while at the<br />

same time allowing the opportunity to grow with<br />

the data centre.<br />

The volume licences for the IP nodes are graduated<br />

from 10 to 1000 nodes and may be adapted<br />

precisely to the size of the data centre. For each<br />

active RimatriX5 component or other SNMP-compatible<br />

component to be covered, one node<br />

licence is required.<br />

For no. of<br />

IP nodes<br />

<strong>Co</strong>nsole<br />

licences included 1)<br />

Model No.<br />

DK<br />

10 2 7990.005<br />

25 4 7990.006<br />

50 4 7990.007<br />

100 8 7990.008<br />

250 10 7990.009<br />

500 15 7990.010<br />

1000 20 7990.011<br />

1) If additional consoles are required, these may be<br />

purchased as Client Access licences.<br />

Client Access licence<br />

Additional licence for operation of another RiZone<br />

console.<br />

Extension<br />

Model No. DK<br />

Client Access licence 7990.013<br />

Microsoft Operations Manager<br />

Management Pack<br />

Management Pack for integrating RiZone into the<br />

Microsoft Operations Manager.<br />

Extension<br />

Microsoft SCOM<br />

Management Pack<br />

Model No. DK<br />

7990.012<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/Monitoring<br />

47


<strong>Co</strong>mmunication Systems<br />

CS wall-mounted enclosures, single-wall, aluminium<br />

B3<br />

T1<br />

B1<br />

B2<br />

H2<br />

T2<br />

H1<br />

H3<br />

Material:<br />

Enclosure, rain canopy and<br />

door:<br />

2.0 mm aluminium AlMg3<br />

<strong>Co</strong>lour:<br />

RAL 7035<br />

Protection category:<br />

IP 55 to EN 60 529<br />

Supply includes:<br />

Single-walled enclosure for wall<br />

or pole mounting, with integral<br />

rain canopy,<br />

door with swing lever handle,<br />

door stay and semi-cylinder,<br />

2-point locking,<br />

external rear panel with two<br />

C rails to accommodate wall<br />

brackets or pole mounting,<br />

mounting plate, screw-fastened<br />

gland plate in the enclosure<br />

base.<br />

Width (B1) mm Packs of 275 447 447 662 852<br />

Height (H1) mm 359 439 654 654 1039<br />

Depth (T1) mm 165 220 310 310 360<br />

Clearance width (B2) mm 170 342 342 557 747<br />

Clearance height (H2) mm 262 342 557 557 942<br />

Clearance depth (T2) mm 125 180 270 270 320<br />

Mounting plate width (B3) mm 162 334 334 549 739<br />

Mounting plate height (H3) mm 275 355 570 570 955<br />

Model No. CS 1 9791.500 9791.510 9791.520 9791.530 9791.540<br />

Accessories<br />

Wall mounting bracket 4 9765.120 9765.120 9765.120 9765.120 9765.120<br />

Pole clamp 1 set 9765.125 9765.125 9765.125 9765.125 9765.125<br />

Semi-cylinder 1 9785.040 9785.040 9785.040 9785.040 9785.040<br />

Heater, 30 W 1 3115.130 3115.130 3115.130 3115.130 3115.130<br />

Thermostat 1 3110.000 3110.000 3110.000 3110.000 3110.000<br />

48 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/<strong>Co</strong>mmunication Systems


System accessories<br />

Gland plate modules, vented<br />

with airflow regulator for DK-TS, FR(i)<br />

Allows controlled air routing from the twin base to<br />

the installed components. Individually adjustable<br />

membranes facilitate control of the air inlet opening<br />

between 10% and 80% free space.<br />

If the rear area of the enclosure is partitioned by<br />

base/gland plates, the required volumetric airflow<br />

may be individually regulated, and distribution of<br />

the airflow inside the twin base adapted to suit the<br />

requirements of each enclosure.<br />

The gland plate module may be combined with all<br />

gland plates as required. Gland plate module<br />

including contacting mounting clamps; the additional<br />

installation of PE conductors is not required.<br />

Material:<br />

Sheet steel<br />

Supply includes:<br />

Packs of 1<br />

gland plate module, vented, filter mat,<br />

assembly parts.<br />

For enclosure width<br />

mm<br />

Model No. DK<br />

600 7825.366<br />

800 7825.386<br />

Also required:<br />

For integration of the gland plates, there must be<br />

a base frame inside the enclosure.<br />

Base frame, divided, for retro-fitting,<br />

see <strong>IT</strong> Catalogue, page 448.<br />

Accessories:<br />

Spare filter mat,<br />

see <strong>IT</strong> Catalogue, page 450.<br />

Side panel, plug-type, divided<br />

for DK-TS<br />

The horizontally divided side panel offers clear<br />

advantages for storage, transportation and<br />

assembly, thanks to the reduced weight and<br />

smaller dimensions of its individual parts. The<br />

lower side panel part is inserted into the base<br />

frame and secured in the centre of the enclosure<br />

via a punched section with mounting flange. After<br />

attaching, the complete side panel is locked at<br />

the top with 2 locks.<br />

Material:<br />

Sheet steel<br />

<strong>Co</strong>lour:<br />

RAL 7035/RAL 9005<br />

Supply includes:<br />

Side panel with security lock 3524 E, punched<br />

section with mounting flange and earth conductor,<br />

assembly parts.<br />

For enclosures<br />

Height<br />

mm<br />

Depth<br />

mm<br />

<strong>Co</strong>lour<br />

Packs<br />

of<br />

Model No.<br />

DK<br />

2000 1200 RAL 7035 1 7824.310<br />

2000 1200 RAL 9005 1 7816.310 1)<br />

2200 1200 RAL 7035 1 7824.312<br />

2200 1200 RAL 9005 1 7816.312 1)<br />

1)<br />

Delivery times available on request.<br />

Roof plate<br />

for cable entry, two-piece,<br />

with brush strip, super-airtight,<br />

for DK-TS, FR(i)<br />

With offset brush trip to ensure optimum sealing<br />

even with large cable volumes. This minimises the<br />

possible ingress of inappropriate air or the unintentional<br />

escape of extinguisher gas or coolant.<br />

The two-piece design also allows convenient retrospective<br />

cable entry, by simply removing the front<br />

part of the plate.<br />

Material:<br />

Roof plate: Sheet steel, spray-finished<br />

Brush strip: Plastic, UL 94-V0<br />

<strong>Co</strong>lour:<br />

Roof plate: RAL 7035<br />

Brush strip: RAL 9005<br />

Supply includes:<br />

Assembly parts.<br />

Width<br />

mm<br />

For enclosures<br />

Depth<br />

mm<br />

Model No. DK<br />

800 800 7526.888<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/System accessories<br />

49


System accessories<br />

Noise protection kit<br />

for TS<br />

Noise insulating mats for equipping or retro-fitting<br />

enclosures.<br />

Thanks to their self-adhesive rear, the noise insulating<br />

mats are conveniently attached to existing<br />

surfaces. Sound is absorbed, for significant noise<br />

reduction. The kit is designed to reduce noise<br />

from the roof, sides and rear of an enclosure with<br />

dimensions WHD 800 x 2000 x 800 mm.<br />

Other dimensions can be accommodated by cutting<br />

to size individually.<br />

Material:<br />

Soft melamine resin-based foam, 20 mm<br />

<strong>Co</strong>lour:<br />

Pale grey<br />

Supply includes:<br />

Spacer bolts for sound decoupling of the roof<br />

plate.<br />

Material category:<br />

B1 to DIN 4102<br />

Note:<br />

Pre-configured enclosures available on request.<br />

1.00<br />

0.90<br />

0.80<br />

0.70<br />

0.60<br />

0.50<br />

α<br />

0.40<br />

0.30<br />

0.20<br />

0.10<br />

For enclosures<br />

W x H x D mm<br />

Packs<br />

of<br />

Model No. DK<br />

800 x 2000 x 800 1 set 7824.650<br />

Absorption level<br />

0.00<br />

63 100 160 250 400 630 1000 1600 2500 4000 6300 10000<br />

Hz<br />

Level of absorption α Share of absorbed output,<br />

1 = 100% (averaged).<br />

Averaged noise reduction<br />

(comparison source, 50 Hz – 20 kHz):<br />

1 m standard distance, averaged level: –10.6 dB (A)<br />

Air block panel, vertical<br />

for DK-TS<br />

Air baffle system for targeted, efficient air diversion<br />

of inlet and outlet air for equipment with side<br />

horizontal ventilation, such as switches. The cold<br />

air flowing in from below is diverted sideways<br />

through the air block panel fitted above the<br />

switches. This helps to largely avoid the mixing of<br />

cold and hot air, and reduce the quantity of cold<br />

air required.<br />

Adjustability:<br />

● In the depth 490 – 770 mm<br />

● Between 482.6 mm (19˝) level and door<br />

94 – 165 mm<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

For<br />

enclosure width Packs of Model No. DK<br />

mm<br />

800 1 set 7151.400<br />

50 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/System accessories


125<br />

96.5<br />

150<br />

System accessories<br />

<strong>Co</strong>mponent shelf,<br />

complete set, pull-out<br />

for TE<br />

Tailored to the distance between levels in enclosures<br />

as per their supplied state of 495 mm, this<br />

complete set contains a vented component shelf,<br />

telescopic slides and a mounting kit for direct<br />

attachment.<br />

The mounting kit also offers depth-variable attachment<br />

within 395 mm to 645 mm on a 25 mm pitch<br />

pattern.<br />

Load capacity:<br />

50 kg, static<br />

Material:<br />

Base: Sheet steel, spray-finished<br />

Mounting kit/telescopic slides:<br />

Zinc-plated, passivated<br />

Supply includes:<br />

<strong>Co</strong>mponent shelf, telescopic slides<br />

and mounting kit.<br />

Base depth<br />

mm<br />

<strong>Co</strong>lour Model No. DK<br />

500 RAL 7035 7000.625<br />

500 RAL 9005 7000.626<br />

Accessories:<br />

Handles for component shelf,<br />

see <strong>IT</strong> Catalogue, page 327.<br />

NEW<br />

Support<br />

for small appliances<br />

For secure attachment of non-482.6 mm (19˝)-<br />

conforming small appliances such as modems,<br />

power packs, routers etc. Angular support for<br />

mounting in the free space at the side between<br />

the 482.6 mm (19˝) level and the side panel on<br />

L-shaped mounting angles, mounting frames or<br />

punched sections.<br />

Attachment of the components and connection<br />

cables can be achieved quickly and easily using<br />

nylon tape or cable ties. Also suitable for cable<br />

routing in the enclosure depth.<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

W x H x D mm Packs of Model No. DK<br />

350 x 150 x 97 1 7246.500<br />

Accessories:<br />

Nylon loop,<br />

cable ties,<br />

see <strong>IT</strong> Catalogue, page 353.<br />

25 25<br />

350<br />

Extension kit<br />

for complete earthing kit<br />

for DK-TS<br />

To DIN EN 60 950/VDE 0805, Ø 4 mm 2 , I max. 40 A.<br />

To extend the complete earthing kit DK 7829.150,<br />

in order to keep additional components potentialfree.<br />

<strong>Co</strong>nductor length 300 mm in each case.<br />

For 6.3 mm flat-pin connectors, 8 mm earthing<br />

bolts or for attachment with contact washers and<br />

screw.<br />

Supply includes:<br />

Assembly parts<br />

and identification labels.<br />

Packs of<br />

Model No. DK<br />

1 set (5 conductors) 7829.152<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/System accessories<br />

51


System accessories<br />

Cable ties<br />

for mounting angles DK-TS and<br />

482.6 mm (19˝) mounting frames<br />

The cable holders allow rear cable routing and<br />

clamping on the 482.6 mm (19˝) mounting level<br />

within the secondary cabling. The integral pitch<br />

pattern of holes supports attachment using cable<br />

ties or nylon type and the direct attachment of<br />

specific trunking cable heads and cable holders.<br />

In this way, individual cables, bundles or trunking<br />

cables may be routed to the distributor level in a<br />

structured way at maximum packing density.<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

Packs of<br />

Model No. DK<br />

2 7611.100<br />

Cable clamp struts<br />

for cable holders<br />

The cable clamp struts may be horizontally<br />

secured between two cable holders and facilitate<br />

cable infeed and strain relieve across the entire<br />

width of the rear patch level. For cascaded cable<br />

routing, the struts may be installed offset in the<br />

depth. The cable clamp struts may be secured<br />

rotationally around the horizontal axis at 45° increments,<br />

to allow individual orientation of the struts<br />

according to the direction from which the cables<br />

are infed. The flexible mounting hole pattern<br />

allows individual use of a wide range of cable<br />

routing aids and the alignment and attachment of<br />

special cable trunking heads.<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

Packs of<br />

Model No. DK<br />

1 7611.110<br />

52 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/System accessories


System accessories<br />

Cable manager<br />

For system-compatible cable deflection while<br />

complying with minimal bending radii and to<br />

accommodate surplus cables and excess length.<br />

The elements may optionally be used individually<br />

or in combination for cable routing. They may be<br />

combined into semi-circular or circular elements.<br />

As the mounting distance between the elements<br />

grows larger, the deflection radius of the cables<br />

may optionally be enlarged, or the cable route<br />

designed individually. The option of securing elements<br />

on their straight-edge side supports the<br />

use of corners and edges, to allow protected<br />

cable routing around them.<br />

Mounting clips for use above the arc hold the<br />

routed cables back within the elements. The elements<br />

are also bayable in an axial direction to<br />

allow U-based cable routing to the mounting level,<br />

or channelling of the cable sections.<br />

Material:<br />

Plastic, UL 94-V0<br />

<strong>Co</strong>lour:<br />

RAL 7035<br />

Supply includes:<br />

Mounting clip<br />

and assembly parts.<br />

Packs of Model No. DK<br />

Basic kit 8 7064.100<br />

Maxi kit 20 7064.110<br />

Cable duct<br />

for TS/TE<br />

For laying cable in particularly high packaging<br />

densities (high density network nodes), in the field<br />

of optical fibre or copper cabling.<br />

Large capacity. A wide range of cable routing,<br />

cable clamping, channelling and cross-cabling<br />

options creates the requirements for maximum<br />

port density in the minimum possible space.<br />

The individual U-related cable routing makes it<br />

possible to dispense with additional cable routing<br />

via patch panels within the distributor level,<br />

thereby equipping every U with connection points.<br />

This increases port density by up to 50%.<br />

The removable duct cover, hinged on both sides,<br />

facilitates user-friendly access at any time. The<br />

cable sections are held back by removable crossbars<br />

to protect them against falling out. Mounting<br />

is either on mounting rails at the sides, or on<br />

mounting angles and mounting frames in the<br />

482.6 mm (19˝) distributor level. Two ducts may<br />

also be secured back-to-back. There is a second,<br />

smaller variant available for intensive partial<br />

installation.<br />

Material:<br />

Cable duct: Sheet steel, spray-finished<br />

Cable routing components: Plastic<br />

Front trim panel: Aluminium, spray-finished<br />

<strong>Co</strong>lour:<br />

RAL 7035<br />

Supply includes:<br />

Hinged front trim panel.<br />

Size<br />

W x D mm<br />

95 x 235<br />

Note:<br />

When using the duct in conjunction with 482.6 mm<br />

(19˝) mounting frames and TS 8, the inner mounting<br />

level in the vicinity of the cable duct is not<br />

available.<br />

Within the duct, additional cable holders may be<br />

attached to accommodate spare cables and for<br />

system-compatible cable deflection.<br />

Accessories:<br />

Cable ties for spare cables:<br />

No. of U Packs of Model No. DK<br />

24 1 7827.310<br />

42 1 7827.320<br />

Packs of<br />

Model No. DK<br />

4 7827.330<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/System accessories<br />

53


System accessories<br />

Anti-twist guard<br />

for cable shunting rings<br />

For individual attachment of cable shunting rings<br />

(DK 7111.000, DK 7111.900, DK 7112.000) to<br />

mounting angles, mounting frames or enclosure<br />

panels. Mounting can be achieved on a 25 mm<br />

pitch pattern of system punchings on mounting<br />

angles and on the 10.5 x 12.5 mm system punchings<br />

of the 482.6 mm (19˝) mounting frame. It may<br />

be variably mounted and rotated on the system<br />

punchings in 90° increments.<br />

Form-fit accommodation of the shunting ring into<br />

the integral channel allows large forces to be<br />

accommodated in all directions.<br />

Material:<br />

Plastic<br />

<strong>Co</strong>lour:<br />

RAL 7035<br />

Packs of<br />

Model No. DK<br />

10 7111.100<br />

Cable management panel<br />

with cable routing bars<br />

482.6 mm (19˝)<br />

For horizontal management of the patch cables<br />

with cable routing bars. Opening the individual<br />

cable routing bars allows user-friendly modification<br />

and extension of the cabling.<br />

Material:<br />

Panel: Sheet steel, spray-finished, RAL 7035<br />

Cable routing bars: Plastic, black<br />

U<br />

Bar depth No. of bars/<br />

mm<br />

U<br />

Model No. DK<br />

1 Approx. 80 5 7257.050<br />

2 Approx. 80 4 7257.150<br />

54 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/System accessories


System accessories<br />

Mounting panel<br />

482.6 mm (19˝), 2 U<br />

For fast integration of smaller mounting units<br />

within the 482.6 mm (19˝) level, such as potential<br />

equalisation rails, distributor boxes, small electrical<br />

components etc.<br />

Simple screw-fastening of the components to the<br />

integral 25 mm system punchings.<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

Panel height<br />

Panel width<br />

mm<br />

Packs of Model No. DK<br />

2 U 450 1 7151.300<br />

TS divider kit, width-variable<br />

482.6 mm (19˝)/metric in TS, FR(i)<br />

Universal depth stays to which both L-shaped<br />

and cranked mounting angles may be variably<br />

mounted in the depth and width.<br />

Divider kit for all width dimensions<br />

● Imperial mounting dimensions 19˝/22˝/23˝/24˝<br />

● Metric mounting dimensions 18/20 SU<br />

Load capacity:<br />

200 kg static load per level<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

For enclosure depth<br />

mm<br />

Packs of Model No. DK<br />

800 1 set 7827.550<br />

1000 1 set 7827.560<br />

1200 1 set 7827.570<br />

Accessories:<br />

Mounting angles 482.6 mm (19˝),<br />

see <strong>IT</strong> Catalogue, page 364.<br />

TS divider kit, heavy-duty,<br />

width/depth-variable<br />

for mounting frame 482.6 mm (19˝ )<br />

in TS, FR(i)<br />

Installation in enclosure width 800 mm<br />

The divider kit allows depth- and width-variable<br />

installation of a 600 mm wide mounting frame,<br />

482.6 mm (19˝), in 800 mm wide enclosures.<br />

Load capacity:<br />

750/1500 kg static load per level/per enclosure<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

Packs of<br />

Model No. DK<br />

1 set 7827.590<br />

Accessories:<br />

Mounting frame 482.6 mm (19˝),<br />

see <strong>IT</strong> Catalogue, page 366.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/System accessories<br />

55


System accessories<br />

Slide rail, depth-variable,<br />

1 U<br />

for server and network enclosures<br />

with two 482.6 mm (19˝) mounting levels,<br />

without additional loss of U<br />

For attachment on both cranked and L-shaped<br />

mounting angles and 482.6 mm (19˝) mounting<br />

frames. The slide rails are pulled out to the<br />

required length and secured between the front<br />

and rear mounting level on the 482.6 mm (19˝)<br />

pitch pattern.<br />

Load capacity:<br />

20 kg static load<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

Distance between<br />

482.6 mm (19˝)<br />

levels<br />

mm<br />

<strong>Co</strong>ntact<br />

surface<br />

mm<br />

Packs<br />

of<br />

Model No.<br />

DK<br />

390 – 600 30 2 7063.750<br />

540 – 750 30 2 7063.752<br />

Note:<br />

Thanks to the thin support surface of only around<br />

0.8 mm thickness, exceeding the U pitch pattern<br />

is generally avoided, provided the components do<br />

not exceed a maximum height of 43.5 mm. In this<br />

way, several units may be easily arranged on top<br />

of one another without offset.<br />

Slide rails<br />

for EL<br />

For the installation of heavy slide-in equipment.<br />

Load capacity per pair:<br />

30 kg static load<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

For hinged part<br />

depth<br />

mm<br />

<strong>Co</strong>ntact<br />

surface<br />

mm<br />

Packs<br />

of<br />

Model No.<br />

EL<br />

216 27 10 2240.000<br />

316 27 10 2250.000<br />

416 27 10 2260.000<br />

516 27 10 2262.000<br />

NEW<br />

Air baffle plates<br />

for TS<br />

Targeted air routing to the components. To prevent<br />

bridges between hot and cold air. Boosts<br />

energy efficiency at the same cooling output.<br />

Mounted all-round on the 482.6 mm (19˝) installation<br />

between the 482.6 mm (19˝) mounting frame<br />

and modular LCP, LCP Plus, side panel or partition.<br />

The width-variable air baffle plates may be individually<br />

adapted to suit the requirements.<br />

In the variant for 800 mm wide enclosures, vertical<br />

482.6 mm (19˝) mounting holes of 3 x 1 U are<br />

additionally integrated, which may be used for<br />

configuration with additional components. Cable<br />

glands with stepped collars distributed across the<br />

height facilitate shielded cable routing between<br />

the front and rear chamber.<br />

In the delivered state, these openings are each<br />

covered with a 1 U blanking panel with snap-in<br />

fastening.<br />

Width<br />

mm<br />

For enclosures<br />

Height<br />

mm<br />

Model No. DK<br />

600 2000 7151.206<br />

800 2000 7151.208<br />

Material:<br />

Air baffle plates:<br />

Sheet steel, spray-finished, RAL 7035<br />

Stepped collar: Plastic, to UL 94-V0<br />

Blanking panel: Plastic, to UL 94-V0, RAL 7035<br />

Supply includes:<br />

2 side air baffle plates, width-variable<br />

1 top air baffle plate, horizontal<br />

For W = 800 mm including blanking panel and<br />

stepped collar.<br />

Note:<br />

Mounting on the internal and external attachment<br />

level in the enclosure depth is not possible.<br />

56 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/System accessories


System accessories<br />

Assembly kit<br />

for VerticalBox<br />

The vertically hinged support plate offers even<br />

more flexibility in interior installation for cable routing,<br />

attachment of small appliances, socket strips<br />

etc.<br />

Depth-variably positionable on a 25 mm pitch<br />

pattern.<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

W x H<br />

mm<br />

Packs of Model No. DK<br />

350 x 485 1 7501.100<br />

Mounting angles,<br />

482.6 mm (19˝)<br />

for VerticalBox<br />

For mounting at the side of the VerticalBox. With<br />

these mounting angles, instead of 5 U vertically<br />

at the side, up to 10 U may be used horizontally<br />

if only a minimal installation depth is required.<br />

Infinitely depth-variable positioning.<br />

Material:<br />

Sheet steel, spray-finished<br />

<strong>Co</strong>lour:<br />

RAL 7035<br />

Supply includes:<br />

Assembly parts.<br />

Note:<br />

10 usable U.<br />

U Packs of Model No. QB<br />

12 2 7502.203<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>/System accessories<br />

57


Lampertz security rooms<br />

Basic protection solution for data centres<br />

The new Lampertz Efficiency Room<br />

<strong>IT</strong> environments today must be flexible, efficient and secure.<br />

Only modular room systems can meet all these requirements and<br />

also offer fast, clean conversions and extensions.<br />

Lampertz Efficiency Rooms (LER) offer uncompromising<br />

flexibility and extremely short delivery times.<br />

System checks are “state of the art”. Why should you, as the<br />

customer, be content with less security, flexibility and long-term<br />

benefits? Only the system testing of a room structure can attest<br />

to the required high level of security for <strong>IT</strong> systems and data.<br />

Benefits:<br />

Efficient value for money<br />

● Optimum use of your investment, due to a growing and modular<br />

structure of the entire data centre<br />

● Absolute investment protection, thanks to the option of complete<br />

dismantling and reassembly of the security room<br />

Efficient design<br />

● Optimum space utilisation of the structural conditions<br />

● Fast assembly times<br />

● Ideal for technology and infrastructure rooms<br />

● Eco-friendly manufacturing technique<br />

Efficient project handling<br />

● Extremely short delivery times (10 working days for basic<br />

package)<br />

● Customised data centre solution, thanks to the flexible modular<br />

principle<br />

● Flexible self-assembly with a supervisor<br />

Efficient climate control concepts<br />

● Optimum air routing, e.g. hot/cold aisle containment<br />

● Efficient climate control technology<br />

System-tested basic protection<br />

● <strong>Co</strong>mpliance with the latest EN and DIN standards<br />

● Multi-functional risk coverage (fire, water, break-ins . . .)<br />

One modular system – infinite possibilities<br />

The new Lampertz Efficiency Rooms are based on the modular principle.<br />

The basic package already includes a solid range of basic<br />

features, and can be adapted to individual customer requirements<br />

with various optional modules.<br />

Application example: Infrastructure room<br />

The Lampertz Efficiency Rooms – LER Basic and LER Extend – are<br />

ideally suited as a technical room for the infrastructure components<br />

of a data centre.<br />

Here, the climate control and power technology are equipped with<br />

a basic level of security.<br />

Basic package<br />

Modular room construction, security functions, door system,<br />

cable duct, delivery and assembly supervisor<br />

Access<br />

monitoring<br />

Cable duct<br />

system<br />

Climate<br />

control<br />

technology<br />

Power<br />

engineering<br />

Fire detection/<br />

fire<br />

extinguishing<br />

Base system<br />

Optional packages<br />

Security, efficiency and availability are at the heart of customer requirements.<br />

The LER option packages include solutions for security,<br />

systems engineering, climate control, power distribution and monitoring.<br />

With these versatile options, <strong>IT</strong> managers can customise their<br />

own precisely tailored, secure, made-to-measure <strong>IT</strong> package.<br />

Full<br />

assembly<br />

Lighting<br />

systems<br />

Monitoring<br />

Project<br />

management<br />

Optical<br />

package<br />

Data and<br />

network<br />

technology<br />

Standard protection from:<br />

Fire<br />

Water used for<br />

fire-fighting<br />

<strong>Co</strong>rrosive gases Vandalism Unauthorised<br />

access<br />

Electro-magnetic<br />

Interference<br />

Dust<br />

Falling debris<br />

Theft/<br />

break-ins<br />

58 Lampertz Security Rooms


Lampertz Efficiency Room<br />

System-tested room construction<br />

Lampertz Efficiency Room<br />

Modular security data centres for basic<br />

protection and extended basic protection.<br />

System-tested room construction in a<br />

modular steel cassette design for both<br />

entire data centres and walls and ceilings.<br />

LER Basic<br />

System testing<br />

Criterion<br />

System test<br />

Fire protection<br />

Testing at<br />

temperatures of up to<br />

1000°C and above<br />

Standards<br />

Testing of the following standards as complete<br />

system or structure<br />

50 K temperature rise and 85% rel. humidity<br />

over 30 minutes, without reheat period<br />

F90 as system test to EN 1363 (DIN 4102),<br />

for the cellular structure and its built-in modules<br />

F120 only as component testing to EN 1363<br />

(DIN 4102), wall system only<br />

F90 only as component testing to EN 1363<br />

(DIN 4102), wall system only<br />

LER<br />

Basic<br />

<br />

LER<br />

Extend<br />

<br />

– <br />

Water<br />

Extinguisher water, IP x6 as system testing<br />

to EN 605 29, for the cellular structure and its<br />

<br />

built-in modules<br />

Rel. humidity, 85%, over 30 minutes – <br />

Dust-proofness IP 5x as system testing to EN 60 529,<br />

for the cellular structure and its built-in modules<br />

<br />

<strong>Co</strong>rrosive fire gases Flue gas-tightness, based on EN 1634-3<br />

(DIN 18095)<br />

– <br />

Unauthorised access WK 3 as system test to EN 1627/1630,<br />

for the cellular structure and its built-in modules, <br />

such as doors<br />

WK 2 as system test to EN 1627/1630,<br />

for the cellular structure and its built-in modules,<br />

such as doors<br />

<br />

EMC protection<br />

Proven by tests on comparable components by<br />

Aachen Technical University<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Note:<br />

System testing refers to testing of an entire room<br />

structure including its built-in modules such<br />

as doors, cable ducts and ventilation units:<br />

<strong>Co</strong>mponent tests have only limited meaningfulness<br />

when applied to complete data centres<br />

and server rooms!<br />

Your particular added benefit:<br />

The Lampertz Efficiency Room generation is an<br />

exemplary, certified data centre construction in<br />

the basic protection solutions market that has<br />

been system-tested to European standards.<br />

● Fire protection: EN 1363 (DIN 4102)<br />

● Unauthorised access: EN 1627<br />

● Water-proofness: EN 60 529<br />

● Dust-proofness: EN 60 529<br />

LER Basic structure:<br />

● Fire and heat-inhibiting element core,<br />

comprised of a thermally effective insulating<br />

substance<br />

● Robust sheet steel sandwich elements<br />

● Innovative element connection with<br />

a stable, zinc-plated profile system<br />

● Security door, F90, up to WK 3<br />

● Use of fire protection valves<br />

● Dismantling and reassembly are possible<br />

at any time<br />

LER Extend structure:<br />

● Fire and heat-inhibiting element core,<br />

comprised of a thermally effective<br />

insulating substance<br />

● Robust sheet steel sandwich elements<br />

● Innovative element connection with<br />

a stable, zinc-plated profile system<br />

● Security door with additional fire protection<br />

insulation, F90, up to WK 3<br />

● Special base sealing<br />

● Use of temperature- and humidityresistant<br />

seals<br />

● Use of climate control valves<br />

● Dismantling and reassembly<br />

are possible at any time<br />

LER Extend<br />

Lampertz Security Rooms<br />

59


2500<br />

1000<br />

2300<br />

100<br />

Lampertz Outdoor data centre<br />

Lampertz Outdoor data centre<br />

The Lampertz Outdoor data centre has been specifically designed<br />

for the temporary use of <strong>IT</strong> systems. It is an energy-efficient solution<br />

with fast availability to accommodate <strong>IT</strong> hardware and 482.6 mm<br />

(19˝) racks, and is available ready to install in next to no time.<br />

Outstanding benefits include the connection of a container with<br />

design features such as free-cooling, extinguisher system and integral<br />

power and emergency power supply. The complete package<br />

ensures reliable usage at optimum operating costs.<br />

The Outdoor data centre is particularly suitable for companies wishing<br />

to use the Lampertz Outdoor data centre for bridging purposes<br />

while an existing data centre is being converted or extended, without<br />

foregoing availability and security. However, the Outdoor data<br />

centre can also be used as an independent main or back-up data<br />

centre.<br />

Illustration shows model L20D<br />

The benefits to you:<br />

Mobility<br />

● Positionable on any area outdoors or indoors suitable for container<br />

siting. The location can also be changed.<br />

Energy efficiency<br />

● By using free cooling technology for climate control, up to 40%<br />

of cooling costs can be saved compared with conventional<br />

climate control units.<br />

Plug and play solution<br />

● The Lampertz Outdoor data centre is supplied ready to use:<br />

Position – connect – and it’s ready to go!<br />

Availability<br />

● The <strong>IT</strong> container will be on site and ready to use in next<br />

to no time – worldwide.<br />

Individuality<br />

● The Lampertz Outdoor data centre is available with <strong>Rittal</strong> TS 8<br />

quality racks (basic version unpopulated). It is also possible to<br />

use existing 482.6 mm (19˝) racks provided by the customer.<br />

Protection properties<br />

● The location may be chosen irrespective of weather conditions.<br />

The Outdoor data centre will withstand rain, wind, heat and cold.<br />

Monitoring<br />

● Whether used with <strong>Co</strong>mputer Multi <strong>Co</strong>ntrol monitoring from <strong>Rittal</strong><br />

or an existing system, our customers have complete control and<br />

a comprehensive overview of the <strong>IT</strong> infrastructures at all times.<br />

Environmental awareness<br />

● We use eco-friendly materials and technologies. This also means<br />

that we use non-toxic extinguisher media.<br />

1<br />

1<br />

2<br />

3<br />

6000<br />

5800<br />

3<br />

3<br />

3 3 4 5<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Climate control 400/740 mm<br />

Electricity 400/600 mm<br />

Rack 600/1000 mm<br />

UPS 600/1000 mm<br />

Extinguisher system 300/1000 mm<br />

1<br />

600<br />

100<br />

Position – connect – and it’s ready to go!<br />

In next to no time, the mobile and energy-efficient Outdoor data<br />

centre is on site and ready to use.<br />

60 Lampertz Security Rooms


Lampertz Outdoor data centre<br />

Lampertz Outdoor<br />

data centre<br />

Even the basic version of the Outdoor<br />

data centre is a fully functional system.<br />

Basic model supply includes:<br />

● <strong>IT</strong> container<br />

● Climate control<br />

● Power distribution<br />

● Raised floor<br />

● Cable ducts<br />

● Access system<br />

The basic modules:<br />

<strong>Co</strong>ntainer:<br />

Steel frame with “made in Germany” sectional<br />

metal facade as a freely supporting<br />

steel frame structure in various RAL colours<br />

(in red RAL 3020 as standard). Walls,<br />

ceilings and bases are in F30 equivalent.<br />

Dimensions:<br />

External<br />

(W x H x D): 2435 x 3000 x 6055 mm<br />

Internal:<br />

(W x H x D): 2270 x 2700 x 5727 mm<br />

Useful area: 13 m 2<br />

Weight: approx. 3.5 tonnes<br />

Floor load: 3500 N/m²<br />

Raised floor:<br />

For air routing and for cable management,<br />

there is a 300 mm high raised floor integrated.<br />

Power distribution:<br />

The supply includes the internal lighting,<br />

one working socket, seven fused outputs<br />

for power supply to the racks, and a multimeasurement<br />

unit for monitoring current<br />

intensity and voltage.<br />

Cable ducts:<br />

Two hard ducts are provided for power<br />

supply and data cabling (two further cable<br />

ducts may additionally be integrated).<br />

Access system:<br />

The door corresponds to resistance<br />

category WK 2.<br />

Option modules<br />

UPS<br />

The energy-efficient UPS is accommodated<br />

in a rack.<br />

Extinguisher system<br />

Fully automated fire extinguisher<br />

system including early fire detection.<br />

482.6 mm (19˝) rack system<br />

Depending on the model, up to seven<br />

482.6 mm (19˝) racks may be integrated.<br />

Power distribution (to/in the) rack<br />

Plug & play power distribution<br />

packages available.<br />

Climate control:<br />

Climate control in free cooling technology 20 kW 2+1 redundant =<br />

is in three output levels:<br />

approx. 5300 euros 1)<br />

7 kW 1+1 redundant = approx. 2500 euros 1)<br />

14 kW 2+1 redundant =<br />

1) Savings per annum compared with a conventional<br />

climate control solution based on<br />

approx. 4400 euros 1) an electricity price of 0.095 euro/kWh.<br />

1<br />

-15 -10 -5 0 5 10 15 20 25 30 35<br />

External air temperature °C<br />

1 Power consumption of air circulation cooling units 23800 kWh/a<br />

2 Lampertz free cooling 3600 kWh/a<br />

2<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

0<br />

Annual energy requirements kWh/a<br />

Access system<br />

Other access systems may alternatively<br />

be used.<br />

Monitoring<br />

The <strong>Co</strong>mputer Multi <strong>Co</strong>ntrol TC<br />

monitors the technical components<br />

and sends error messages.<br />

<strong>Co</strong>lours<br />

The Lampertz Outdoor data centre is<br />

available in various RAL colours.<br />

Cable duct<br />

Two cable ducts (hard ducts) may<br />

additionally be supplied.<br />

Solar protection<br />

A sun shade is available for outdoor<br />

siting.<br />

Service/maintenance<br />

Servicing once per annum.<br />

Lampertz Security Rooms<br />

61


List of model numbers<br />

Model No.<br />

Page<br />

Model No.<br />

Page<br />

Model No.<br />

Page<br />

Model No.<br />

Page<br />

Model No.<br />

Page<br />

2240.000 56<br />

7246.500 51<br />

7820.870 12<br />

7830.220 9<br />

9791.510 48<br />

2250.000 56<br />

7257.050 54<br />

7820.880 12<br />

7830.230 9<br />

9791.520 48<br />

2260.000 56<br />

7257.150 54<br />

7820.882 12<br />

7830.240 9<br />

9791.530 48<br />

2262.000 56<br />

7320.101 34<br />

7820.890 12<br />

7830.250 9<br />

9791.540 48<br />

3300.230 32<br />

7320.111 41<br />

7820.892 12<br />

7830.270 9<br />

3300.239 32<br />

7320.112 35<br />

7820.950 12<br />

7830.300 10<br />

3300.260 33<br />

7320.210 39, 41<br />

7820.952 12<br />

7830.320 10<br />

3300.261 33<br />

7320.248 37<br />

7821.100 11<br />

7830.330 10<br />

3300.262 33<br />

7320.425 41<br />

7821.200 11<br />

7830.335 10<br />

3300.263 33<br />

7320.435 41<br />

7821.240 11<br />

7830.340 10<br />

3300.290 33<br />

7320.440 41<br />

7821.300 11<br />

7830.350 10<br />

3300.291 33<br />

7320.450 41<br />

7821.340 11<br />

7830.370 10<br />

3300.292 33<br />

7320.530 39<br />

7821.355 11<br />

7830.380 10<br />

3300.293 33<br />

7320.721 37<br />

7821.400 11<br />

7830.800 9<br />

3300.294 33<br />

7320.790 41<br />

7821.410 11<br />

7830.850 9<br />

3300.295 33<br />

7320.791 41<br />

7821.440 11<br />

7831.730 15<br />

3300.296 33<br />

7320.792 41<br />

7821.500 11<br />

7831.732 15<br />

3300.297 33<br />

7320.793 41<br />

7821.510 11<br />

7831.740 15<br />

3300.420 30<br />

7320.820 36<br />

7821.540 11<br />

7831.742 15<br />

3300.480 28<br />

7338.110 39<br />

7821.600 11<br />

7831.752 15<br />

3301.210 30<br />

7338.200 39<br />

7821.610 11<br />

7831.762 15<br />

3301.230 30<br />

7338.300 39<br />

7821.620 11<br />

7831.800 17<br />

3301.420 30<br />

7338.310 39<br />

7821.640 11<br />

7831.802 17<br />

3301.460 29<br />

7501.000 13<br />

7821.650 12<br />

7831.803 17<br />

3301.470 31<br />

7501.100 57<br />

7821.670 12<br />

7831.810 17<br />

3301.475 31<br />

7502.203 57<br />

7821.700 12<br />

7831.812 17<br />

3301.480 28<br />

7526.888 49<br />

7821.710 12<br />

7831.813 17<br />

3301.790 29<br />

7611.100 52<br />

7821.720 12<br />

7831.830 17<br />

3301.980 31<br />

7611.110 52<br />

7821.730 12<br />

7831.850 16<br />

7000.625 51<br />

7816.310 49<br />

7821.740 12<br />

7856.003 20<br />

7000.626 51<br />

7816.312 49<br />

7821.750 12<br />

7856.005 20<br />

7000.875 14<br />

7820.100 11<br />

7821.760 12<br />

7856.006 20<br />

7000.882 14<br />

7820.200 11<br />

7821.770 12<br />

7856.008 20<br />

7000.885 14<br />

7820.240 11<br />

7821.800 12<br />

7856.043 21<br />

7000.892 14<br />

7820.300 11<br />

7821.810 12<br />

7856.095 21<br />

7000.895 14<br />

7820.340 11<br />

7821.830 12<br />

7856.719 43<br />

7000.930 8<br />

7820.350 11<br />

7821.832 12<br />

7856.722 43<br />

7000.934 8<br />

7820.355 11<br />

7821.840 12<br />

7856.731 43<br />

7000.940 8<br />

7820.360 11<br />

7821.850 12<br />

7856.734 43<br />

7000.942 8<br />

7820.400 11<br />

7821.860 12<br />

7857.420 23<br />

7000.944 8<br />

7820.410 11<br />

7821.870 12<br />

7857.423 23<br />

7000.946 8<br />

7820.440 11<br />

7821.880 12<br />

7857.424 23<br />

7000.960 8<br />

7820.500 11<br />

7821.882 12<br />

7859.222 19<br />

7000.962 8<br />

7820.510 11<br />

7821.890 12<br />

7859.225 19<br />

7040.010 24<br />

7820.540 11<br />

7821.892 12<br />

7859.232 19<br />

7040.020 24<br />

7820.600 11<br />

7821.950 12<br />

7859.235 19<br />

7040.030 24<br />

7820.610 11<br />

7821.952 12<br />

7890.020 43<br />

7040.040 24<br />

7820.620 11<br />

7824.310 49<br />

7890.206 43<br />

7040.110 24<br />

7820.640 11<br />

7824.312 49<br />

7890.208 43<br />

7040.120 24<br />

7820.650 12<br />

7824.650 50<br />

7890.226 43<br />

7040.200 24<br />

7820.670 12<br />

7825.366 49<br />

7890.228 43<br />

7040.210 24<br />

7820.700 12<br />

7825.386 49<br />

7890.500 43<br />

7063.750 56<br />

7820.710 12<br />

7827.310 53<br />

7990.001 47<br />

7063.752 56<br />

7820.720 12<br />

7827.320 53<br />

7990.002 47<br />

7064.100 53<br />

7820.730 12<br />

7827.330 53<br />

7990.003 47<br />

7064.110 53<br />

7820.740 12<br />

7827.550 55<br />

7990.004 47<br />

7111.100 54<br />

7820.750 12<br />

7827.560 55<br />

7990.005 47<br />

7151.206 56<br />

7820.760 12<br />

7827.570 55<br />

7990.006 47<br />

7151.208 56<br />

7820.770 12<br />

7827.590 55<br />

7990.007 47<br />

7151.300 55<br />

7820.800 12<br />

7829.152 51<br />

7990.008 47<br />

7151.400 50<br />

7820.810 12<br />

7830.100 9<br />

7990.009 47<br />

7200.210 39, 41<br />

7820.830 12<br />

7830.110 9<br />

7990.010 47<br />

7200.211 41<br />

7820.832 12<br />

7830.120 10<br />

7990.011 47<br />

7200.213 41<br />

7820.840 12<br />

7830.130 10<br />

7990.012 47<br />

7200.214 41<br />

7820.850 12<br />

7830.200 9<br />

7990.013 47<br />

7200.215 41<br />

7820.860 12<br />

7830.202 9<br />

9791.500 48<br />

62 <strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong>


A<br />

Active Power System Module<br />

PSM/Power <strong>Co</strong>ntrol Unit PCU 18, 19<br />

Add-on unit<br />

– GSM Unit Quad-Band 36<br />

Air baffle plates for TS 56<br />

Air block panel, vertical 50<br />

Anti-twist guard 54<br />

Automatic Door <strong>Co</strong>ntrol Unit 41<br />

Automatic Door Kit 41<br />

Automatic door switch 41<br />

B<br />

Basic CMC plus 35<br />

C<br />

Cable clamp struts 52<br />

Cable duct for TS/TE 53<br />

Cable management panel<br />

with cable routing bars 54<br />

Cable manager 53<br />

Cable ties 52, 53<br />

CMC-TC monitoring system<br />

– Add-on GSM unit 36<br />

– Basic CMC plus 35<br />

– Processing Unit II plus (PU II plus) 34<br />

CMC-TC sensor units 36<br />

<strong>Co</strong>mfort handle TS 8 CCP<br />

– with master key function 37<br />

<strong>Co</strong>mponent shelf for TE 51<br />

<strong>Co</strong>nnection kit 33<br />

<strong>Co</strong>oling module<br />

– for LCP Standard 30<br />

CS wall-mounted enclosures 48<br />

D<br />

Depth-variable slide rails 56<br />

Distributor frame TE 7000 open 8<br />

Dynamic Rack <strong>Co</strong>ntrol 42, 43<br />

E<br />

Energy-saving extractor plenum 33<br />

Extension kit for complete earthing kit 51<br />

F<br />

Front cover 31<br />

G<br />

Gland plate modules, vented 49<br />

GSM Unit Quad-Band 36<br />

H<br />

Heat exchanger<br />

– LCP Inline 31<br />

– LCP Plus EC 28<br />

– LCP Smart 29<br />

– LCP Standard 30<br />

– LCP T3+/LCP T3+ EC 32<br />

High density cable duct 53<br />

HPC racks<br />

– for high performance cooling 17<br />

L<br />

Lampertz<br />

– Efficiency Room 58, 59<br />

– Outdoor data centre 60, 61<br />

LCP Inline 31<br />

LCP Plus/LCP Plus EC 28<br />

LCP Smart 29<br />

LCP Standard 30<br />

LCP T3+/LCP T3+ EC 32<br />

Liquid cooling package 26 – 32<br />

M<br />

Microsoft Operations Manager 47<br />

Modular Power <strong>Co</strong>ncept PMC 40 22 – 25<br />

Monitoring system CMC-TC<br />

– Basic CMC plus 35<br />

– Processing Unit II plus 34<br />

Mounting angles, 482.6 mm (19˝)<br />

– for VerticalBox 57<br />

Mounting kit for VerticalBox 57<br />

Mounting panel 482.6 mm (19˝), 2 U 55<br />

N<br />

Network enclosures<br />

– Based on <strong>Rittal</strong> TE 7000 open 8<br />

– Based on <strong>Rittal</strong> TS 8 9 – 12<br />

Noise protection kit for TS 50<br />

P<br />

Plug-in modules, active PSM 19<br />

PMC 40 22 – 25<br />

PMC 40 basic unit 24<br />

PMC 40 battery pack 24<br />

PMC 40 UPS module 24<br />

Power <strong>Co</strong>ntrol Unit<br />

with individual current measurement 19<br />

Processing Unit II plus 34<br />

PSM<br />

– Busbar 20, 21<br />

PSM busbar with fixed infeed/RCD 21<br />

PSM plug-in module with integral RCD 21<br />

R<br />

Index<br />

Rack extinguisher system<br />

DET-AC Plus short 38 – 40<br />

RFID controller 43<br />

RFID mounting frame 43<br />

RFID tags 43<br />

RiZone –<br />

Data Centre<br />

Management Software 44 – 47<br />

Roof plate<br />

– for cable entry, super-airtight 49<br />

S<br />

Server racks 15 – 17<br />

– Based on <strong>Rittal</strong> TE 7000 14<br />

– Based on <strong>Rittal</strong> TS 8, Plus 16<br />

– Based on <strong>Rittal</strong> TS 8, pre-configured 15<br />

– for high performance cooling 17<br />

Side panel, plug-type, divided 49<br />

Slide rails for EL 56<br />

Software RiZone 44 – 47<br />

Sound insulating mats for TS 50<br />

Spare battery for wireless sensors 37<br />

Support<br />

– for small appliances 51<br />

T<br />

TE 7000<br />

– Open, distributor frame 8<br />

– Server racks 14<br />

Touchscreen display<br />

– for LCP Smart 29<br />

TS 8 enclosures<br />

– Network enclosures 9 – 12<br />

– Server racks 15 – 17<br />

TS divider kit, variable<br />

– for mounting angles 55<br />

– for mounting frame 55<br />

U<br />

UPS, three-phase, PMC 40 22 – 25<br />

V<br />

VerticalBox 13<br />

W<br />

Wall-mounted enclosures CS 48<br />

We reserve the right to further developments<br />

and technical modifications of<br />

our products. Such modifications, along<br />

with errors and printing errata, shall not<br />

constitute grounds for compensation.<br />

We refer customers to our Terms of Sale<br />

and Delivery.<br />

<strong>Rittal</strong> <strong>IT</strong> <strong>News</strong> <strong>2009</strong><br />

63


All in all – solutions from <strong>Rittal</strong><br />

Industrial Enclosures<br />

Power Distribution<br />

Electronic Packaging<br />

System Climate <strong>Co</strong>ntrol<br />

<strong>IT</strong> Solutions<br />

Network enclosures Server racks KVM technology<br />

Telco racks Office solutions Distributor racks<br />

Wall-mounted enclosures RimatriX5 Power management<br />

concepts <strong>IT</strong> cooling Monitoring Security Services Kiosks<br />

<strong>Co</strong>mmunication Systems<br />

Outdoor enclosures Climate control units<br />

System integration<br />

<strong>Rittal</strong> has one of the largest ranges of enclosures available<br />

for immediate delivery. However, <strong>Rittal</strong> also supplies integrated<br />

solutions – up to Level 4. This comprises mechanical<br />

installation, power supply, electronic components, climate<br />

control and central monitoring. For all of your requirements.<br />

Fully assembled and functional. Wherever in the world you<br />

develop and implement solutions for yourself and your<br />

customers, we are close at hand. The global alliance<br />

between production, distribution and service guarantees<br />

closeness to the customer. Worldwide!<br />

05/09 E572E<br />

<strong>Rittal</strong> <strong>GmbH</strong> & <strong>Co</strong>. <strong>KG</strong> Postfach 1662 D-35726 Herborn<br />

Telephone: +49(0)2772 505-0 Telefax: +49(0)2772 505-2319 eMail: info@rittal.de www.rittal.com<br />

R<br />

Switch to perfection

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!