26.04.2015 Views

Certificate Number: 98-018A3 Page 1 of 2 1135 M ... - Mettler Toledo

Certificate Number: 98-018A3 Page 1 of 2 1135 M ... - Mettler Toledo

Certificate Number: 98-018A3 Page 1 of 2 1135 M ... - Mettler Toledo

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Certificate</strong> <strong>Number</strong>: <strong>98</strong>-<strong>018A3</strong><br />

<strong>Page</strong> 1 <strong>of</strong> 2<br />

For:<br />

Computing Scale<br />

Weight Classifier, Digital Electronic<br />

Model: PS6L<br />

n max : 4 800<br />

e min : 0.1 oz<br />

Capacity: (see below)<br />

Platform: 11.8 in x 13.8 in<br />

Accuracy Class: III<br />

Submitted By:<br />

<strong>Mettler</strong>-<strong>Toledo</strong>, Inc.<br />

1150 Dearborn Drive<br />

Worthington, OH 43085<br />

Tel: 614-438-4387<br />

Fax: 614-438-4355<br />

Contact: Scott Davidson<br />

Email: scott.davidson@mt.com<br />

Web site: www.mt.com<br />

Standard Features and Options<br />

Standard Features:<br />

Semi-automatic Zero Setting Mechanism<br />

Gross Display<br />

Automatic Zero Setting Mechanism<br />

lb, kg, or lb/oz units<br />

Initial Zero Setting Mechanism<br />

RS-232 Communication Port<br />

Screen Saver Feature (automatic shut-<strong>of</strong>f)<br />

Stainless Steel Platform<br />

AC/DC Adapter<br />

Options:<br />

Ball Transfer Plate<br />

Multi-Interval (lb/oz only)<br />

Remote Display<br />

Multi-Range (lb/oz only)<br />

Load Cell Used:<br />

<strong>Mettler</strong>-<strong>Toledo</strong> Eagle Plus, 100 kg (non-NTEP)<br />

Multi-Interval:<br />

0 – 10 lb x 0.1 oz; 10 – 70 lb x 0.2 oz; 70 – 150 lb x 0.5 oz (can be set up for a maximum <strong>of</strong> 149 lb)<br />

Multi-Range:<br />

Range 1: 0 – 10 lb x 0.1 oz ; Range 2: 0 – 100 lb x 0.5 oz<br />

Temperature Range: 10 ºC to 40 ºC (50 ºF to 104 ºF)<br />

This device was evaluated under the National Type Evaluation Program and was found to comply with the applicable technical requirements <strong>of</strong> "NIST Handbook 44:<br />

Specifications, Tolerances and Other Technical Requirements for Weighing and Measuring Devices." Evaluation results and device characteristics necessary for<br />

inspection and use in commerce are on the following pages.<br />

Tim Tyson<br />

Chairman, NCWM, Inc.<br />

Randy Jennings<br />

Chairman, National Type Evaluation Program Committee<br />

Issued: November 5, 2010<br />

<strong>1135</strong> M Street, Suite 110 / Lincoln, Nebraska 68508<br />

The National Conference on Weights and Measures (NCWM) does not approve, recommend or endorse any proprietary product or material, either as a single item or as<br />

a class or group. Results shall not be used in advertising or sales promotion to indicate explicit or implicit endorsement <strong>of</strong> the product or material by the NCWM.


<strong>Certificate</strong> <strong>Number</strong>: <strong>98</strong>-<strong>018A3</strong><br />

<strong>Page</strong> 2 <strong>of</strong> 2<br />

<strong>Mettler</strong>-<strong>Toledo</strong>, Inc.<br />

Computing Scale / PS6L<br />

Application: Weight classifier, postal/shipping scale for determining postal charges. The scale will be marked "WEIGHT<br />

CLASSIFIER FOR POSTAL USE." The weight classifier rounds weight values up to the next scale division in normal operation and<br />

in testing.<br />

Identification: The required information appears on an adhesive badge under the platter attached to the base <strong>of</strong> the scale.<br />

Sealing: The scale is sealed by means <strong>of</strong> a wire security seal threaded through a screw in an access platter that covers the setup<br />

features.<br />

Operation: Multi-interval and multi-range features are optional. Both features are protected behind the security seal. When set-up as<br />

a multi-interval or multi-range scale the division size and range will change division sizes automatically as appropriate.<br />

Test Conditions: This certificate supersedes <strong>Certificate</strong> <strong>of</strong> Conformance <strong>98</strong>-018A2 and is issued to include multiple range capability<br />

in the Standard Features and Options Box. The multiple range feature was evaluated in an NTEP laboratory. The previous test<br />

condition is listed below as reference.<br />

<strong>Certificate</strong> <strong>of</strong> Conformance <strong>Number</strong> <strong>98</strong>-018A2: This certificate supersedes <strong>Certificate</strong> <strong>of</strong> Conformance <strong>98</strong>-018A1 and is issued to<br />

clarify that Range 3 can be selected for a maximum <strong>of</strong> 149 to 150 lb. Previous test data and information supplied by the company was<br />

reviewed. No additional testing was required.<br />

<strong>Certificate</strong> <strong>of</strong> Conformance <strong>Number</strong> <strong>98</strong>-018A1: This certificate supersedes <strong>Certificate</strong> <strong>of</strong> Conformance <strong>98</strong>-018 and is issued to add<br />

a second range <strong>of</strong> capacities to the existing device. Previous test data and information supplied by the company was reviewed. No<br />

additional testing was required.<br />

<strong>Certificate</strong> <strong>of</strong> Conformance <strong>Number</strong> <strong>98</strong>-018: The emphasis <strong>of</strong> the evaluation was on the device design, operation, and compliance<br />

with influence factor and marking requirements. Several increasing/decreasing load and shift tests were performed with a power<br />

supply <strong>of</strong> 100 VAC or 130 VAC applied to the scale. The scale was tested over a temperature range <strong>of</strong> 10 C to 40 C<br />

(50 F to 104 F). A load <strong>of</strong> approximately one-half scale capacity was applied to the scale 100 800 times. The scale was tested<br />

periodically during this time.<br />

Evaluated By: A. McCoy (OH) <strong>98</strong>-018, M. Kelley (OH) <strong>98</strong>-<strong>018A3</strong><br />

Type Evaluation Criteria Used: NIST, Handbook 44: Specifications, Tolerances and Other Technical Requirements for Weighing<br />

and Measuring Devices, 2010. NCWM, Publication 14: Weighing Devices, 2010.<br />

Conclusion: The results <strong>of</strong> the evaluation and information provided by the manufacturer indicate the device complies with applicable<br />

requirements.<br />

Information Reviewed By: S. Patoray (NCWM) <strong>98</strong>-018A1, <strong>98</strong>-018A2; L. Bernetich (NCWM) <strong>98</strong>-018A2; J. Truex (NCWM)<br />

<strong>98</strong>-<strong>018A3</strong><br />

Example <strong>of</strong> Device:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!