Step 11: action result<br />

To select a detection delay time of Ø, 1, 3 or<br />

4 seconds at detection point 4, press the<br />

number key, then press ENTER. For a 2<br />

second delay time, press the ENTER key<br />

to select the default and continue.<br />

Audio Lane1 On Y/N?<br />

Enter 1=Yes, Ø=No:Ø<br />

Step 12: action result<br />

If you want to measure the greeting delay<br />

time in lane 1, press key 1, then press ENTER.<br />

If not, press the Ø key, then press ENTER.<br />

Audio Lane2 On Y/N?<br />

Enter 1=Yes, Ø=No:1<br />

Step 13: action result<br />

(Scenario 4 only.) If you want to measure the<br />

greeting delay time in lane 2, press ENTER.<br />

If not, press the Ø key, then press ENTER.<br />

Pullout Time Setting<br />

Que Max (Ø-180s):12Ø<br />

Step 14: action result<br />

To leave the queue pullout time at 1<strong>20</strong> seconds,<br />

press ENTER. To change the que pullout time,<br />

press the number keys, then press ENTER.<br />

Pullout Time Setting<br />

Serv Window Idle:6Ø<br />

NOTE: To account for pullouts, the <strong>system</strong> will discard the times for a vehicle if the<br />

conditions described in both Steps 14 and 15 are met. If a car does not arrive at<br />

the service window within 1<strong>20</strong> seconds (or whatever other queue pullout time you<br />

selected) after leaving the menu board; and if a car does not arrive at the service<br />

window within 60 seconds (or whatever other service window time you selected)<br />

after the last car left.<br />

Step 15: action result<br />

To leave the service pullout time at 60 seconds,<br />

press ENTER. To change it, press the<br />

number keys, then press ENTER.<br />

Ø6/Ø7/95 16:Ø4:Ø2<br />

Enter command or ESC<br />

This completes the Installer System Setup.<br />