Rapid Environmental Impact Assessment (REIA) Study <strong>for</strong> Proposed Integrated Complex <strong>for</strong> Delhi Judicial Academy,<br />

National Law School, and National Institute <strong>for</strong> Mediation & Conciliation at Dwarka, New Delhi<br />

The standby electric generator shall be installed to supply power to staircase and corridor<br />

lighting circuit, ventilation and smoke extraction system, lifts, exit signs and fire pump in<br />

case of failure of normal electric supply.<br />

The construction of electric sub station and installation of trans<strong>for</strong>mers, LT and HT<br />

panels shall be as per the provisions specified by the DVB authorities. The HT and LT<br />

panels shall be separated with the walls of 4 hrs fire rating. Each trans<strong>for</strong>mer will be<br />

separated from the other by fire resistant shield wall extending up to one meters on sides<br />

above the highest point of the trans<strong>for</strong>mer so that fire risk is minimized. HT and LT<br />

panels shall be protected with manually operated CO2 protection system.<br />

Automatic sprinklers shall be installed in the entire building. The portable fire<br />

extinguishers shall be provided at strategic locations. Automatic fire detection system i.e.<br />

smoke / heat detection system shall be provided in the buildings. The system shall be<br />

connected to the fire alarm system. An emergency intercommunication system shall be<br />

provided <strong>for</strong> the entire building. The control room / security room with communication<br />

system to all floors and facility <strong>for</strong> receiving messages from different floors shall be<br />

provided at entrance on ground floor.<br />

It is also <strong>proposed</strong> to appoint a qualified fire officer in the building to maintain / look<br />

after fire fighting system / fire order. To prevent any fire hazard, good house keeping<br />

inside and outside the building shall be strictly maintained.<br />

7.6 Rainwater Harvesting Plan<br />

The project will adopt all appropriate methods on the <strong>proposed</strong> site <strong>for</strong> harvesting of<br />

rainwater. Four nos. of rainwater collecting pits having boreholes going to the permeable<br />

strata level will be provided in the <strong>complex</strong>.<br />