INSTALLATION DRAWING<br />

MATING CONN.ECTOR<br />

DENISON #721-30018 REF.<br />

SERVOVALVE<br />

ELECTRIC CONNECTOR<br />

BENDIX #PC02H-8-4P (REF)<br />

1"<br />

"H1" 1 -12 UNF 37˚ FLARED TYPE SAE ELBOW<br />

16<br />

AUX. PUMP (SERVO & REPLEN.) INLET FROM<br />

EXTERNAL FILTER<br />

AS SHOWN<br />

P 1<br />

T<br />

2<br />

4MA/DC/NOM.<br />

4MA/DC/NOM.<br />

SERVOVALVE WIRING SCHEMATIC<br />

A<br />

B<br />

C<br />

D<br />

DENISON #099-13142<br />

11.29<br />

( 286,8)<br />

7.44<br />

( 188,9)<br />

MATING CONN.<br />

DENISON #721-30059 REF.<br />

CODE<br />

NO<br />

1<br />

T<br />

P<br />

2<br />

1.75<br />

( 44,5)<br />

RED<br />

B<br />

B<br />

+15VDC<br />

COLUMBUS, OH<br />

U. S. A.<br />

+15VDC<br />

OUT<br />

BLUE<br />

C<br />

C<br />

OUT<br />

8.54<br />

( 216,9)<br />

F<br />

O<br />

F<br />

COMMON<br />

GREEN<br />

F<br />

F<br />

-15VDC<br />

BLACK<br />

D<br />

D<br />

C<br />

-15VDC<br />

POTENTIOMETER RVDT WIRING WIRING SCHEMATIC SCHEMATIC<br />

DENISON #788-20002<br />

2.4VDC OUT AT 19˚ CAM ANGLE<br />

VIEW A-A<br />

OPTIONAL<br />

MANUAL SERVOVALVE SHUT-OFF<br />

SHOWN IN OPEN POSITION<br />

(ROTATE 90˚ TO SHUT-OFF)<br />

8.14<br />

(206,7)<br />

19˚<br />

MAX.<br />

19˚<br />

MAX.<br />

"S"-SERVO VALVE INLET<br />

SAE-8 STR. THD.<br />

"KG"-REPLENISHING PRESS. GAGE CONN.<br />

SAE-6 STR. THD.<br />

A<br />

11.31<br />

( 287,3 )<br />

2.55<br />

( 64,8)<br />

7.51<br />

( 190,8)<br />

F<br />

O<br />

F<br />

B<br />

A<br />

A<br />

NOTES:<br />

CONTROL<br />

OPTION<br />

"7E2"<br />

-B- CONTROL MTG. POSITION<br />

PUMP<br />

PACKAGE<br />

P24P<br />

&<br />

P30P<br />

PUMP<br />

ROT.<br />

CW<br />

CCW<br />

CW<br />

CCW<br />

VOLUME INDICATOR<br />

SHAFT ROTATION<br />

CCW<br />

CW<br />

CW<br />

CCW<br />

PORT<br />

"A"<br />

INLET<br />

INLET<br />

OUTLET<br />

OUTLET<br />

PORT<br />

"B"<br />

OUTLET<br />

OUTLET<br />

INLET<br />

INLET<br />

1. FOR DIMENSIONS & PORT IDENTIFICATIONS NOT SHOWN<br />

SEE THE APPROPRIATE BASIC PUMP INSTALLATION:<br />

P24P BASIC INSTALLATION (LESS CONTROLS) 23-9922-D<br />

P30P BASIC INSTALLATION (LESS CONTROLS) 23-9913-D<br />

2. REFERENCE TO PUMP ROTATION, R-CW & L-CCW, IS AS<br />

VIEWED FROM SHAFT END.<br />

3. DIMENSIONS IN PARENTHESIS ARE METRIC (SI UNITS).<br />

P24/30P P24/30P W/ W/ “7E2-B” "7E2-B" CONTROL CONTROL W/WO W/WO COMPENSATOR<br />

SHUT-OFF SHUT-OFF & WITH FEEDBACK & WITH RVDT POTENTIOMETER<br />

CW/CCW CW/CCW ROTATION, ROTATION, SAE-F SAE-F 4-BOLT 4-BOLT MOUNTING<br />

23-9923<br />

55