17.04.2015 Views

CLINICAL RESULTS WITH THE EC-1Y ... - Aaren Scientific

CLINICAL RESULTS WITH THE EC-1Y ... - Aaren Scientific

CLINICAL RESULTS WITH THE EC-1Y ... - Aaren Scientific

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>CLINICAL</strong> <strong>RESULTS</strong><br />

<strong>WITH</strong> <strong>THE</strong> <strong>EC</strong>-<strong>1Y</strong>:<br />

satisfaction after one year<br />

JEAN-MICHEL BOSC, MD, FRANCE<br />

Georgina Rosca, MD , FRANCE


<strong>Aaren</strong> <strong>Scientific</strong> <strong>EC</strong>-<strong>1Y</strong><br />

(Formerly OII)<br />

• Technical presentation<br />

– The IOL<br />

• Implantation and difficulties<br />

– Glutting and coating<br />

• 1 year results<br />

– Clinical evaluation<br />

– Personal impressions


<strong>EC</strong>-<strong>1Y</strong> Single-Piece Iol<br />

Very good stability and prevention of PCO<br />

• Yellow hydrophobic acrylic<br />

material<br />

• New high-efficiency benzotriazole<br />

UV absorber<br />

• Bound azo-type yellow dye<br />

• Blue light filtered with percent<br />

transmission of approx 50% at<br />

450nm<br />

• Double square-edge around<br />

entire periphery<br />

• Finite Elemental Analysis (FEA)<br />

geometry designed to minimize<br />

capsular bag stretching, but to<br />

conform the optic edge for<br />

maximum capsular adhesion.


<strong>EC</strong>-<strong>1Y</strong><br />

Miyake Posterior Photos<br />

Alcon AcrySof<br />

<strong>Aaren</strong> <strong>Scientific</strong> <strong>EC</strong>-<strong>1Y</strong>


Implantation and difficulties<br />

Sticking haptic<br />

• Sticking is visco dependent :<br />

– HPMC : no problem<br />

– Provisc +<br />

– Duovisc+++<br />

– Healon ++<br />

– Visthesia +<br />

– Discovisc ++<br />

• Heparin treatment surface could be a solution?<br />

• Sticking management :<br />

– visco bimanual management (Hook and spatula)<br />

– manual releasing of the two surfaces haptic - optic<br />

haptic - haptic


Implantation <strong>EC</strong>1 Y and difficulties<br />

Coating of optic surface<br />

• Coating is cartridge dependent:<br />

– Alcon: no problem<br />

– Ophtec: no problem<br />

– Medicel ++<br />

– MDJ +++<br />

• Coating consequences : PCO ?<br />

• Prevention : preloaded heparin coated IOL ?


1 YEAR <strong>RESULTS</strong> <strong>WITH</strong> <strong>EC</strong>-<strong>1Y</strong><br />

<strong>CLINICAL</strong> EVALUATION<br />

Inclusion criterias<br />

• At least 50 years of age<br />

• Primary IOL implantation<br />

• No anterior segment pathology<br />

• No previous retinal detachment or retinal<br />

pathology<br />

• No ocular disorders that could possibly cause<br />

loss of VA


1 YEAR <strong>RESULTS</strong> <strong>WITH</strong> <strong>EC</strong>-<strong>1Y</strong><br />

<strong>CLINICAL</strong> EVALUATION<br />

Postoperative examination<br />

• Uncorrected and best corrected visual acuity<br />

• Slit – lamp examinations (assessement of lens<br />

positioning and transparency, glistenings or<br />

vacuoles)<br />

• Expected and unexpected complications<br />

• Results at 1 month, 6 months and 1 year


1 YEAR <strong>RESULTS</strong> <strong>WITH</strong> <strong>EC</strong>-<strong>1Y</strong><br />

<strong>CLINICAL</strong> EVALUATION: UCVA


1 YEAR <strong>RESULTS</strong> <strong>WITH</strong> <strong>EC</strong>-<strong>1Y</strong><br />

<strong>CLINICAL</strong> EVALUATION: BCVA<br />

6 months SE = -0.30 D<br />

12 months SE = -0.20 D


1 YEAR <strong>RESULTS</strong> <strong>WITH</strong> <strong>EC</strong>-<strong>1Y</strong><br />

<strong>CLINICAL</strong> EVALUATION<br />

Reported complications<br />

• There have been no significant complications<br />

related to the lens<br />

• No IOL decentration<br />

• No IOL opacities<br />

• No PCO<br />

• No glistenings or vacuoles


1 YEAR <strong>RESULTS</strong> <strong>WITH</strong> <strong>EC</strong>-<strong>1Y</strong><br />

PERSONAL IMPRESSIONS<br />

790 implantations<br />

• No PCO (1 YAG)<br />

• A-Constant : 118.4


CONCLUSIONS<br />

• <strong>EC</strong>-1yellow from OII lab. shows an excellent<br />

centration and very good behavior in the short<br />

term<br />

• IOL implantation easy and reproducible (incision<br />

2.2 mm)<br />

• Good visual outcomes<br />

• Next future developments : asphericity, heparin<br />

surface treatment, preloaded IOL<br />

• Future : Multifocality, toricity