<strong>Family</strong> <strong>of</strong> <strong>Products</strong><br />

Hydrophobic Yellow Aspheric<br />

Preloaded


Lens-prep+ Power Range: 4.0 to 26.0 in 0.5D increments.


Available<br />

With<br />

Lens-prep +<br />

Available<br />

With<br />

Lens-prep +<br />

*Glass Transition Temperature<br />

Design:<br />

Overall Diameter:<br />

Optic<br />

Bi-Convex<br />

13.0mm<br />

Optic Diameter:<br />

6.0 or 6.5 mm<br />

A-Constant**:<br />

118.2mm<br />

Refractive Index: 1.49<br />

AC-Depth**: 5.1<br />

Haptics:<br />

Design:<br />

Modified C<br />

Angulation: 5º<br />

Material:<br />

PVDF u<br />

u<br />

Polyvinylidene Fluoride<br />

Power Range: 4.0 to 34.0D (in 0.5D increments)<br />

Optic<br />

Design:<br />

Bi-Convex<br />

Overall Diameter:<br />

13.0mm<br />

Optic Diameter:<br />

6.0mm<br />

A-Constant**:<br />

118.1mm<br />

Refractive Index: 1.49<br />

AC-Depth**: 5.1<br />

Angulation: 5º<br />

Power Range: 4.0 to 34.0D (in 0.5D increments)<br />

** A-Constant and AC-Depth are estimated and not based on clinical data.


The P.U.R.E. System<br />

Precision UnResolved-materials Extraction<br />

P.U.R.E. is a unique molecular cleaning method developed by <strong>Aaren</strong> <strong>Scientific</strong> to remove materials and<br />

extraneous processing materials found in hydrophilic lenses that are not fully polymerized. <strong>Aaren</strong> lenses<br />

that go through the P.U.R.E. System have enduring optical clarity and enhanced biocompatibility. ALL<br />

<strong>Aaren</strong> hydrophilic acrylic lenses are being treated with this proprietary system. Purity is verified by routine<br />

use <strong>of</strong> high sensitivity mass spectrometry (MS) chemical analysis.<br />

Over 1,000,000 P.U.R.E. lenses sold.<br />

* A-Constants and AC-Depths are estimated and not based on clinical data. u Polyvinylidene Fluoride


Benefits <strong>of</strong> Heparin Surface Modification<br />

• Reduces postoperative inflammatory responses in the early postoperative period.**<br />

• Results in reduced foreign-body reactions as measured by specular microscopy and slit-lamp<br />

examination, especially in the early postoperative period.**<br />

• Appears to be a valuable tool to decrease implant-associated bacterial endophthalmitis.**<br />

• HSM posterior IOLs result in less cellular response observed one year after extra-capsular<br />

cataract extraction.**<br />

• Patients who are diabetic or have glaucoma can definitely benefit from an HSM acrylic IOL<br />

compared to a non-HSM PMMA IOL, according to a multi-center study.**<br />

(**Statements taken from industry articles on file.)<br />

u Polyvinylidene Fluoride<br />

* A-Constants and AC-Depths are estimated and not based on clinical data.


Introducing and Aspheric Lenses...<br />

Traditional spherical IOLs are subject to aberrations that result in slightly distorted images on the retina -<br />

particularly at large pupil diameter. This is because light rays that enter the eye peripherally undergo stronger<br />

refraction than those that enter centrally. One <strong>of</strong> the benefits <strong>of</strong> <strong>Aaren</strong> PAL aspheric lenses is improved<br />

contrast sensitivity, especially in low<br />

MTF in Eye Model with Simulated Human Cornea<br />

MTF in Eye Model with Simulated Human Cornea<br />

5mm Aperture with 0.5mm Lens Decentration*<br />

5mm Aperture with 1.0mm Lens Decentration*<br />

light (large pupil) conditions.<br />

1.0<br />

1.0<br />

The optics <strong>of</strong> <strong>Aaren</strong> <strong>Scientific</strong>’s<br />

Precision Aspheric Lenses (PAL)<br />

are designed to compensate for<br />

the aberrations <strong>of</strong> the human eye<br />

to achieve exceptional optical<br />

performance - even in instances <strong>of</strong><br />

naturally occurred IOL misalignment.<br />

MTF<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0.0<br />

0<br />

10 20 30 40 50 60 70 80 90 100<br />

Spatial Frequency (cycles/mm)<br />

MTF<br />

0.0<br />

0<br />

(100 cycles/mm equivalent to 20/20 vision)<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

10 20 30 40 50 60 70 80 90 100<br />

Spatial Frequency (cycles/mm)<br />

MTF (Modulation Transfer Function)<br />

analysis shows the significantly<br />

improved image quality <strong>of</strong> an <strong>Aaren</strong><br />

PAL hydrophilic lens to a typical<br />

aspheric lens, under various degrees<br />

<strong>of</strong> decentration and tilt. In addition,<br />

the MTF <strong>of</strong> PAL is comparable to or<br />

better than that <strong>of</strong> a spherical optic<br />

under these same conditions.<br />

MTF<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0.0<br />

0<br />

MTF in Eye Model with Simulated Human<br />

Cornea 5mm Aperture with 0.5mm Lens<br />

y-decentration and 7degrees x-tilt*<br />

MTF<br />

MTF in Eye Model with Simulated Human<br />

Cornea 5mm Aperture with 0.5mm Lens<br />

y-decentration and 7degrees y-tilt*<br />

0.0<br />

10 20 30 40 50 60 70 80 90 100<br />

0 10 20 30 40 50 60 70 80 90 100<br />

Spatial Frequency (cycles/mm)<br />

Spatial Frequency (cycles/mm)<br />

*Best Focus defined at 3mm aperture prior to determining MTF at 5mm.<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

PAL optics are<br />

now available on<br />

most Aqua-Sense ®<br />

and BioVue ® lens<br />

models.


For flexible haptics,<br />

we recommend our SP<br />

lens series.<br />

For firmer haptics,<br />

please try our XP series<br />

Standard Power Range: 4.0 to 30.0 in 0.5D increments.<br />

* Power Range, Low: 0.5 to 3.5 in 0.5D increments.<br />

** Power Range, Negative: -0.5 to -12.0 in 0.5D increments.<br />

“A” Constants and AC Depths are estimated<br />

and not based on clinical data.


Viscoelastics and<br />

Tension Rings<br />

27 G<br />

cannula<br />

<strong>Aaren</strong> <strong>Scientific</strong> ® Bio-Clear ® is a high-quality,<br />

high-molecular weight viscoelastic made<br />

from highly purified hyaluronic acid from<br />

rooster comb.<br />

PMMA Capsular Tension Rings<br />

Precision medical devices for insertion in the capsular bag<br />

Suggested Indications:<br />

• Weak or missing zonules<br />

• IOL subluxation<br />

• Expected complications during<br />

phaco surgery<br />

Advantages:<br />

• Maintains circular expansion <strong>of</strong><br />

capsular bag<br />

• Stabilizes conditions during surgery<br />

• Improves IOL centration<br />

• Minimizes risk <strong>of</strong> capsular fibrosis<br />

• Prevents capsular collapse<br />

®<br />

4290 East Brickell Street, Bldg. A<br />

Ontario, CA 91761 USA<br />

Tel: (909) 937-1033 • Fax: (909) 937-1088<br />

E-mail: info@aareninc.com<br />

Web: www.aareninc.com<br />

P/N: 3227 J<br />

Copyright © 2009 <strong>Aaren</strong> <strong>Scientific</strong> Inc. ® All Rights Reserved.