T.C<br />

ALH<br />

TEMPERATURE CONTROLLER<br />

DX SERIES<br />

P.I.D.ControlwithAuto-tuningMicroprocessorbaseddigital<strong>temperature</strong>/process<strong>controller</strong>s.<br />

MODEL<br />

DX9<br />

DX7<br />

3TEMPERATURECONTROLLER<br />

Appearance<br />

External dimension<br />

Input<br />

Accuracy<br />

96X96mm(1/4DIN),mountingdepth:100mm<br />

Thermocouple(K.J.R),R.T.D.(DIN/JISPt100Ω),mV&mA<br />

72X72mm,mountingdepth:100mm<br />

[Settingaccuracy]T/C:Within±(0.5%ofSV+1digit)or±3℃[6℉](Whicheverislarger)<br />

R.Input:0~199℃[0~399℉]Within±5℃[10℉]<br />

R.T.D:Within±(0.5%ofSV+1digit)or±1℃[3℉](Whicheverislarger)<br />

[Displayaccuracy]Sameassettingaccuracy<br />

Power supply<br />

Control action<br />

Control output<br />

100~240VAC±10%(50/60Hz)<br />

PID(Auto-tuningfunction),ON/OFF,P·PI· PD<br />

Relaycontact:AC250V1C(NO-5A/NC-3A)(Resistiveload)<br />

SSRdriving: 0/12VDC(Constantvoltagepulse)[loadresistancemorethan800Ω]<br />

Current:4-20mADC[loadresistancelessthan600Ω]<br />

Alarm output<br />

Ambient<br />

<strong>temperature</strong><br />

Deviationorprocesssetting<br />

Relaycontactoutput:AC250V0.5A(AL-2,LBA),3A(AL-1)<br />

0~50℃(32~122℉)※Ambienthumidity:35~85%RH<br />

Net weight<br />

Approx320g<br />

Approx250g<br />

120 68 +0.7<br />

-0<br />

Panel cutout<br />

90 +0.8<br />

0<br />

68 +0.7<br />

0<br />

90 +0.8<br />

0<br />

82<br />

Connection<br />

10<br />

9<br />

8<br />

7<br />

RETRANSMISSION<br />

+<br />

OUTPUT <br />

6<br />

4~20mA DC<br />

5<br />

RTDINPUT<br />

B<br />

4 4<br />

3 3<br />

B<br />

RTD<br />

A<br />

2<br />

+<br />

2<br />

T.C<br />

1 1<br />

ALL<br />

LBA<br />

ALH<br />

20<br />

19<br />

18<br />

17<br />

16<br />

b C<br />

15<br />

a<br />

14<br />

13<br />

H C<br />

12<br />

L<br />

11<br />

100 240VAC<br />

50/60Hz<br />

12VA<br />

CURRENT/SSR<br />

+<br />

12 OUTPUT<br />

4~20mA DC/SSR(12VDC)<br />

11<br />

MAIN<br />

COM<br />

RTDINPUT<br />

7<br />

LBA 6<br />

ALL 5<br />

4<br />

3<br />

2<br />

1<br />

4<br />

B<br />

3<br />

B<br />

RTD 2<br />

+<br />

1<br />

14<br />

13<br />

19<br />

18<br />

17<br />

16<br />

15<br />

H<br />

C<br />

14 MAIN<br />

L<br />

13<br />

+<br />

100 - 240VAC<br />

CURRENT/SSR<br />

OUTPUT<br />

4~20mA DC/SSR(12VDC)<br />

60


TEMPERATURE CONTROLLER<br />

DX SERIES<br />

DX2<br />

DX3<br />

DX4<br />

3<br />

48X96mm(1/8DIN),mountingdepth:100mm<br />

96X48mm(Horizontal),mountingdepth:100mm<br />

Thermocouple(K.J.R),R.T.D.(DIN/JISPt100Ω),mV&mA<br />

[Settingaccuracy]T/C:Within±(0.5%ofSV+1digit)or±3℃[6℉](Whicheverislarger)<br />

R.Input:0~199℃[0~399℉]Within±5℃[10℉]<br />

R.T.D:Within±(0.5%ofSV+1digit)or1℃[3℉](Whicheverislarger)<br />

[Displayaccuracy]Sameassettingaccuracy<br />

48X48mm(1/16DIN),mountingdepth:100mm<br />

TEMPERATURECONTROLLER<br />

100~240VAC±10%(50/60Hz)<br />

PID(Auto-tuningfunction),ON/OFF,P·PI· PD<br />

Relaycontact:AC250V1C(NO-5A/NC-3A)(Resistiveload)<br />

SSRdriving:0/12VDC(Constantvoltagepulse)[loadresistancemorethan800Ω]<br />

Current:4-20mADC[loadresistancelessthan600Ω]<br />

Deviationorprocesssetting<br />

Relaycontactoutput:AC250V0.5A(AL-2,LBA),3A(AL-1)<br />

Relaycontact:AC250V5A(Resistiveload)<br />

SSRdriving:0/12VDC(Constantvoltagepulse)<br />

[loadresistancemorethan800Ω]<br />

Current:4-20mADC[loadresistancelessthan600Ω]<br />

Deviationorprocesssetting,singlealarm<br />

Relaycontactoutput:AC250V3A<br />

(Resistiveload)<br />

0~50℃(32~122℉)※Ambienthumidity:35~85%RH<br />

Approx260g<br />

Approx250g<br />

Approx180g<br />

120<br />

30<br />

91 +0.8<br />

0<br />

45 +0.6<br />

0<br />

25<br />

45 +0.5<br />

0<br />

45 +0.5<br />

0<br />

20 20<br />

10<br />

ALL<br />

9<br />

8<br />

LBA<br />

7<br />

RETRANSMISSION<br />

OUTPUT +<br />

<br />

6<br />

4 20mA DC<br />

5<br />

RTDINPUT<br />

B<br />

4<br />

4<br />

3<br />

3<br />

RTD<br />

B<br />

+<br />

2<br />

2<br />

TC<br />

1<br />

1<br />

A<br />

b<br />

C<br />

a<br />

H C<br />

L<br />

20<br />

19<br />

100 ~ 240V AC<br />

18 50/ 60Hz<br />

17<br />

16<br />

15 ALH<br />

14<br />

+<br />

12<br />

4 20mA DC/SSR(12V DC)<br />

13<br />

11<br />

12 MAIN<br />

11<br />

10 9 8 7<br />

ALL<br />

AC100 240V<br />

LBA<br />

ALH<br />

20 18 17 15<br />

16 14<br />

19 13<br />

c<br />

b a H<br />

6 5<br />

+<br />

4~20mA DC<br />

RETRANSMISSION<br />

OUTPUT<br />

MAIN<br />

C<br />

12 11<br />

L<br />

4 3 2 1<br />

+ TC<br />

B<br />

+<br />

0/12V DC<br />

4~20mA DC<br />

12 11<br />

Voltagepulse<br />

output.<br />

Currentoutput<br />

4 3 2 1<br />

B<br />

RTD<br />

RTDINPUT<br />

A<br />

4~20mA DC/SSR(12VDC)<br />

5<br />

+<br />

11 6<br />

ALM/LBA<br />

2<br />

3<br />

4 4<br />

5<br />

Power source<br />

100 240VAC<br />

MAIN<br />

7<br />

8 T.C<br />

9<br />

✽ Terminal2 and3 are<br />

connectedforALH,ALLandLBA<br />

+<br />

7<br />

8<br />

9<br />

B<br />

B<br />

A<br />

RTD<br />

61


TEMPERATURE CONTROLLER<br />

DX SERIES<br />

3TEMPERATURECONTROLLER<br />

■ Operation Manual<br />

This maunal primarily describes precautions required in<br />

installingandwiringthe<strong>temperature</strong><strong>controller</strong>.<br />

WeherewithintroduceoperationofDX9 foryourreference.<br />

■ Functional Description<br />

5<br />

6<br />

7<br />

10<br />

11<br />

C<br />

INPUT<br />

OUT<br />

MODE<br />

PV<br />

SV<br />

AT LBA ALH ALL<br />

OUTPUT<br />

1 Process-value(PV)displayunit(Green)<br />

2 Set-value(SV)displayunit(Red)<br />

3 Highalarm(ALH)lamp(Red)<br />

4 Lowalarm(ALL)lamp(Red)<br />

5 Controlloopbreakalarm(LBA)actionindicatinglamp(Red)<br />

6 Auto-tuning(AT)lamp(Green)<br />

7 Controloutput(OUT)lamp(Green)<br />

8 Set-valueincrementkey<br />

9 Set-valuedecrementkey<br />

10 Mode(SET)key<br />

11 Shiftkeyofsettingdigit<br />

■ Operation<br />

● Description of each parameter<br />

When the power is turned ON, the process-value(PV) display unit<br />

shows a process-value and the set-value(SV) display unit shows a<br />

MODE<br />

set-value. Pressing the key changes the mode and the<br />

parameterasshowninthefollowing.<br />

DX9<br />

1<br />

2<br />

3<br />

4<br />

8<br />

9<br />

·PV/SV display and SV setting modes<br />

Process<br />

value(PV)<br />

displayunit<br />

Processvalue<br />

Set-value(SV)<br />

displayunit<br />

Set-value(SV)<br />

Description<br />

Displayprocessvalue.<br />

Set-value(SV)<br />

canbeset. ✽ 1<br />

Initial-valueprior<br />

toshipment<br />

0or<br />

0.0℃(℉)<br />

✽1:Set-value(SV)isacontroltarget.Itissettablewithintheinputrange.<br />

MODE<br />

✽<br />

2<br />

✽<br />

3<br />

● Parameter setting mode<br />

Pressthekeycontinuouslyfor5sec.<br />

MODE<br />

(If no key operation is performed for 1 minute, the<br />

<strong>controller</strong> returns to the PV/SV display mode<br />

automatically)<br />

Process<br />

value(PV)<br />

display unit<br />

Name<br />

Highalarm<br />

Lowalarm<br />

Proportional<br />

band<br />

Antiresetwind-up<br />

Integraltime<br />

Derivative<br />

time<br />

Controlloop<br />

breakalarm<br />

Proportioning<br />

cycle<br />

Hysteresis(in DisplayshysteresisofSet-Valueformain<br />

ON/OFFaction) output.<br />

Fullscale<br />

limit<br />

Underscale<br />

limit<br />

Setdatalock<br />

Description<br />

DisplaysHighalarmset-value.<br />

DisplaysLowalarmset-value.<br />

Setwhenproportionalcontrolisperformed.<br />

ControlbecomesON/OFFactionwithP<br />

setto“O”or“O.O”.<br />

Prevents overshoot and/or undershoot<br />

causedbyintegralaction.<br />

Integral action is turned OFF with ARW<br />

setto“O”.<br />

Eliminatesoffsetoccurringinproportional<br />

control.IntegralactionturnsOFFwith<br />

thisactionsetto“O”.<br />

Prevents ripples by predicting output<br />

changetherebyimprovingcontrolstability.<br />

Derivative action turns OFF with this<br />

actionsetto“O”.<br />

Indicatescontrolloopbreakalarm<br />

setting.<br />

Displaysmanipulatedoutputcycle(sec.).<br />

Relaycontactoutput:20sec.<br />

Voltagepulseoutput:2sec.<br />

Transmittingoutputsignalcorrespondsto<br />

thefullscalelimit.<br />

Transmittingoutputsignalcorrespondsto<br />

theunderscalelimit.<br />

TurnsthesetdatalockON/OFF.<br />

✽2/✽3(option)···NodisplaywhenRetransmission<br />

outputisnotattached.<br />

62


MODE<br />

MODE<br />

MODE<br />

MODE<br />

MODE<br />

MODE<br />

MODE<br />

MODE<br />

MODE<br />

PV<br />

PV<br />

SV<br />

SV<br />

PV<br />

PV<br />

SV<br />

PV<br />

SV<br />

PV<br />

TEMPERATURE<br />

SV<br />

CONTROLLER<br />

DX SERIES<br />

PV<br />

PV<br />

SV<br />

PV<br />

SV<br />

SV<br />

PV<br />

PV<br />

SV<br />

PV<br />

SV<br />

SV<br />

● Each parameter setting<br />

PV<br />

(1)Set-value(SV)settingprocedure<br />

PV<br />

Thefollowingareexamplesofsettingthesetvalue(SV)to70℃.(PV:25℃)<br />

SV<br />

C<br />

INPUT<br />

C<br />

OUT AT LBA ALH ALL<br />

OUTPUT<br />

OUT AT LBA ALH ALL<br />

SVPV<br />

PV<br />

PV<br />

PV<br />

SV<br />

SV<br />

SV<br />

PV<br />

PV<br />

SV<br />

PV PV<br />

PV<br />

SV SV<br />

SV<br />

PV<br />

PV PV<br />

SV<br />

SV SV<br />

PV<br />

PV<br />

SV<br />

SV<br />

SV<br />

SV<br />

DX9<br />

1<br />

MODE<br />

PressthekeytoentertheSV<br />

setting mode. The last digit of<br />

the set-value(SV) display unit<br />

starts to flicker. The digit which<br />

flickersissettable.<br />

PV<br />

2<br />

Pressthekeytoshift thedigit<br />

SV<br />

which flickers up to the two<br />

digits. The digit which flickers<br />

shiftsasfollowseverytimethe<br />

keyispressed:<br />

PV<br />

(2)Eachparameter(otherthanSV)settingprocedure<br />

PV<br />

Thisparametersettingexampleshowsthatthe<br />

proportional band(P)issetto20℃.<br />

PV SV<br />

C<br />

INPUT<br />

C<br />

INPUT<br />

OUT AT LBA ALH ALL<br />

OUTPUT<br />

SV<br />

PV<br />

SV<br />

PV<br />

PV PV<br />

SV<br />

PV<br />

SVPV<br />

SV<br />

SV<br />

PV DX9<br />

PV<br />

SV<br />

PV<br />

OUT AT LBA ALH ALLPVPV<br />

PV<br />

OUTPUT<br />

SV<br />

SV<br />

SV SV<br />

PV<br />

SV<br />

PV<br />

DX9<br />

SV<br />

SV<br />

1<br />

PV<br />

MODE<br />

Pressing thekey continuously<br />

SV<br />

for 5 sec. Set the <strong>controller</strong> to<br />

the parameter setting mode<br />

(other than SV). Thus, the<br />

parameter symbol is shown on<br />

the process-valus (PV) display<br />

unit. The last digit also flickers.<br />

The digit which is flickering is<br />

settable.<br />

2<br />

MODE<br />

Press thekey to display the<br />

proportional band (P) parameter<br />

PV<br />

symbol( ) on the process-value<br />

(PV)displayunit.<br />

SV<br />

3<br />

TEMPERATURECONTROLLER<br />

INPUT<br />

C<br />

INPUT<br />

C<br />

OUTPUT<br />

OUT AT LBA ALH ALL<br />

OUTPUT<br />

OUT AT LBA ALH ALL<br />

DX9<br />

PV<br />

SV<br />

PV<br />

PV<br />

SV<br />

PV<br />

PV<br />

SV<br />

PV<br />

SV<br />

DX9 SV<br />

SV<br />

PV<br />

SV<br />

SV<br />

PV<br />

PV<br />

SV<br />

SV<br />

PV<br />

SV<br />

PV<br />

PV<br />

SV<br />

PV<br />

SV<br />

PV<br />

3<br />

Pressthekeytoset“7”.<br />

Pressing thekey digit PV goes up<br />

and pressing thekey digit comes<br />

SV<br />

down.<br />

·Settingrange:Withininputrange.<br />

Whenmines(-)signisset,<br />

Example:<br />

When 70 is changed to -70, shift<br />

the digit flickering to the two<br />

digits,thenpressthekeytofor<br />

thedigitcomingdownindueorder<br />

of1→0→-1.<br />

4<br />

After finishing the setting, press<br />

MODE<br />

the key. All of the set-value<br />

digits stop flickering and as a<br />

result, the <strong>controller</strong> returns to<br />

thePV/SVdisplaymode.<br />

C<br />

INPUT<br />

C<br />

INPUT<br />

PV<br />

PV<br />

SV<br />

SV<br />

PV<br />

OUT AT LBA ALH ALL<br />

PV<br />

SV<br />

PV<br />

SV<br />

DX9<br />

SV<br />

OUTPUT<br />

PV<br />

PV<br />

PV<br />

SV<br />

PV<br />

SV<br />

SV<br />

OUT AT LBA ALH ALL<br />

SV<br />

PV<br />

SV<br />

PV<br />

PV<br />

DX9<br />

SV<br />

OUTPUT<br />

PV SV<br />

PV<br />

SV<br />

SV<br />

PV<br />

3<br />

Press the key to shift the<br />

digitwhichflickersuptothetwo<br />

digits.<br />

The digit which flickers shifts as<br />

follows every time thekey is<br />

pressed.<br />

PV<br />

SV<br />

4<br />

Pressthekeytoset“2”.<br />

Pressingthekey,thedigit<br />

goesup,andpressingthe<br />

key,thedigitcomesdown.<br />

PV<br />

SV<br />

INPUT<br />

OUTPUT<br />

DX9<br />

SV<br />

PV<br />

PV<br />

SV<br />

PV<br />

SV<br />

MODE<br />

✽ Ifthesettingends,pressingthekeycontinuouslyfor5<br />

sec,againreturnsthe<strong>controller</strong>tothePV/SVdisplaymode.<br />

In addition, if no key operation is performed for 1 minute,<br />

the <strong>controller</strong> is set to the PV/SV display mode<br />

automatically.<br />

C<br />

INPUT<br />

PV<br />

SV<br />

SV<br />

PV<br />

PV<br />

PV<br />

OUT AT LBA ALH ALL<br />

SV<br />

PV<br />

SV<br />

SV<br />

DX9 SV<br />

OUTPUT<br />

PV<br />

PV<br />

SV<br />

5<br />

MODE<br />

Pressing thekey after the<br />

setting ends shifts to the next<br />

parameter.Repeattheprocedures<br />

as shown from 2 to 5 to shift<br />

eachparameterinturn.<br />

SV<br />

63<br />

PV<br />

PV<br />

SV<br />

PV<br />

SV<br />

PVSV<br />

PV<br />

SV<br />

PV<br />

SV


TEMPERATURE CONTROLLER<br />

DX SERIES<br />

3TEMPERATURECONTROLLER<br />

Each parameter symbol and setting range are<br />

shown in the following.<br />

Name<br />

High alarm<br />

Low alarm<br />

Proportional<br />

band<br />

Anti-reset<br />

wind-up<br />

Integral time<br />

Derivative time<br />

Control loop<br />

break alarm<br />

Proportioning<br />

cycle<br />

Hysteresis(in<br />

ON/OFF action)<br />

Full scale limit<br />

(Option)<br />

Parameter<br />

Symbol<br />

Setting Range<br />

-199to1770℃(℉)or<br />

-199.9to999.9℃(℉)<br />

-199to1770℃(℉)or<br />

-199.9to999.9℃(℉)<br />

1tospan℃(℉)or0.1tospan℃(℉)<br />

(ON/OFFactionwithPsetto“0”or“0.0”)<br />

1tospan℃(℉)or0.1tospan℃(℉)<br />

(1 actionturnsOFFwiththisactionsetto“0”)<br />

1to3600sec.<br />

(IactionturnsOFFwithIsetto“0”)<br />

1to3600sec.<br />

(DactionturnsOFFwithDsetto“0”)<br />

1to7200sec.<br />

(Settingbelow“0”cannotbemade)<br />

1to100sec.<br />

0.1to100.0℃(℉)or1to100℃(℉)<br />

Min.toMax.scalepointInstrument.<br />

anddeterminesbytheamountofchangewhetherLBA<br />

istobeONorOFF.<br />

1 Whenthestatusata100%PIDcomputedvalue<br />

continuesbeyondtheLBAsettingtime,theLBA<br />

turnsONifthemeasured-value(PV)doesnotrise<br />

by2℃(℉)ormore.<br />

(Indirectaction,theabovealarmturnsONifthe<br />

measured-valuedoesnotfallby2℃(℉)ormore.<br />

2 Whenthestatusat0%PIDcomputedvalue<br />

continuesbeyondtheLBAsettingtime,theLBA<br />

turnsONifthemeasured-value(PV)doesnotfall<br />

by2℃(℉)ormore.<br />

(Indirectaction,theabovealarmturnsONifthe<br />

measured-valuedoesnotriseby2℃(℉)ormore.)<br />

● Causes of activation<br />

TheLBAisactivatedunderthefollowingconditions.<br />

1 Controlled object trouble .... Heater break, no power<br />

supply,incorrectwiring,etc.<br />

2 Sensortrouble .... Sensordisconnected,shorted,etc.<br />

3 Actuator trouble .... Burnt relay contact, incorrect wiring,<br />

relaycontactnotclosed,etc.<br />

4 Output circuit trouble .... Burnt internal relay contact,<br />

relaycontactnotopenorclosed,etc.<br />

5 Input circuit trouble .... The measured-value does not<br />

changeevenifinputchanges,etc.<br />

* If causes of the above trouble cannot be identified,<br />

checkthecontrolsystem.<br />

64<br />

Under scale<br />

limit(Option)<br />

Set data lock<br />

■ Main Functions<br />

Min.toMax.scalepointInstrument.<br />

0000:Nosetdatalocked.<br />

0001:Onlytheset-value(SV)is<br />

changeablewiththesetdatalocked.<br />

0010/0011:Setdatalocked.<br />

● Control loop break alarm (LBA) function<br />

(1) Setting procedure<br />

Usuallysettheset-valueoftheLBAtoavalueof<br />

twicetheintegraltime(I).<br />

TheLBAcanalsobesetbytheauto-tuning(AT)<br />

function.Inthiscase,theset-valueisautomaticallyset<br />

toavalueoftwicetheintegraltime(I).<br />

(2) Description of operation<br />

LBAfunctionstartstomeasuretimefromthemoment<br />

thatthePIDComputedValue(OutputONtime/cycle)<br />

become0%or100%,anddetectstheamountof<br />

ProcessValuechangeateachLBAsettingtime,<br />

● Cautions for control loop break alarm (LBA) function<br />

1 TheLBAfunctionisactivatedonlyatthe0%or100%<br />

PIDcomputedvalue.<br />

Therefore, the time from trouble occurrence till the<br />

activationoftheLBAfunctionequalsthetimeuntilPID<br />

computed value becomes 0% or 100% plus the LBA<br />

settingtime.<br />

2 The LBA function is activated while the auto-tuning<br />

(AT)functionisactivated.<br />

3 The LBA function is influenced by disturbances (heat<br />

sources,etc.)andasaresultmaybeactivatedevenif<br />

thereisnotroubleinthecontrolsystem.<br />

4 IfLBAsettingtimeistooshortordoesnotmatchthe<br />

controlledobject,theabovealarmmaynotbeturned<br />

ONandOFFornotbeturnedON.Insuchacase,set<br />

thesettingofLBAtobeslightlylonger.


TEMPERATURE CONTROLLER<br />

DX SERIES<br />

● Alarm function<br />

Theactionforeachalarmbecomesasfollows:<br />

(▲:Set-value(SV)▵:Alarmset-value)<br />

·Freelyadjustablehysteresis<br />

Adjustablerange:0-100or0.0-100.0℃(℉,or%)<br />

Highalarm<br />

Hysteresiswidth<br />

Controloutput<br />

Hysteresiswidth<br />

·Deviation alarm<br />

High&Lowalarm<br />

Bandalarm<br />

Low<br />

Low<br />

ON<br />

OFF<br />

ALL<br />

ALL<br />

OFF<br />

ON<br />

ALH<br />

ALH<br />

✽ BandalarmoperatesonlyALHrelay.<br />

·Process alarm<br />

High&Lowalarm<br />

Low<br />

ON<br />

ALL<br />

OFF<br />

ALH<br />

ON<br />

OFF<br />

ON<br />

High<br />

High<br />

High<br />

Low<br />

OFF<br />

■ Circuit Configuration<br />

As shown in the following diagram, each of the power,<br />

input, MCU, and output blocks of the DX9 is mutually<br />

isolated.<br />

Isolated<br />

setpoint<br />

ON<br />

High<br />

Powersupply<br />

Isolated<br />

Low<br />

ON<br />

setpoint<br />

OFF<br />

Isolated<br />

High<br />

3<br />

TEMPERATURECONTROLLER<br />

Bandalarm<br />

● Overscale and underscale<br />

1 If a measured value exceeds the high setting range<br />

limitduetoupscale,etc.,measured-valuedisplaystarts<br />

flashing.<br />

Further,ifitexceedsthehighinputdisplayrangelimit,<br />

themeasured-value(PV)displayunitflashesoverscale<br />

display「“ ”」<br />

2 Ifameasured-valuebecomesbelowthelowsetting<br />

rangelimitduetodownscale,etc.,measured-value<br />

displaystartsflashing.<br />

Further,ifitbecomesbelowthelowinputdisplay<br />

rangelimit,themeasured-value(PV)displayunit<br />

flashesunder-scaledisplay「“ ”」<br />

● Hold function<br />

Low<br />

OFF<br />

ALL<br />

·After power is applied, the low alarm is turned on<br />

during the <strong>temperature</strong> rises. If this is not desired, the<br />

low alarm can be suspended after power is applied until<br />

the temperatre goes out of the alarm setting range by<br />

addingtheholdfunction.(Fig.2)<br />

Withoutholdfunction<br />

setpoint<br />

(Lowalarm)<br />

PowerON<br />

PVvalue<br />

Alarmoutput ON OFF ON OFF<br />

fig.1<br />

PowerON<br />

ON<br />

Withholdfunction<br />

setpoint<br />

(Lowalarm)<br />

ALH<br />

OFF<br />

High<br />

PVvalue<br />

Alarmoutput OFF OFF ON OFF<br />

fig.2<br />

Input Isolated MCU Isolated Output<br />

DX9circuitconfiguration<br />

■ Selection of Initial Set Mode<br />

<br />

Do the setting according to the specifications of the<br />

<strong>controller</strong>supplied.Ifyouselectwronginputoroutput,it<br />

causes the malfunctions. Set according to the input or<br />

outputspecificationsasshowninsideoffrontlid.<br />

(1)SettheDipswitchontheinnerPCBtoINITIALset.<br />

NORMAL<br />

INITIAL<br />

(2)Turnonthepower,then displaysontheProcess<br />

Valuedisplayunit(PV),whichisinthestateofinitial<br />

setting.<br />

(3)Pushthemodekey,thentheParameterswillbe<br />

changedasfollows:<br />

[] [] [] []<br />

PV-displayUnit<br />

SV-displayUnit<br />

(Inputmodefixed)<br />

SV-Display unit<br />

0000<br />

0001<br />

0010<br />

0011<br />

0100<br />

0101<br />

Description<br />

CurrentorVoltage<br />

K(CA)<br />

JISPt100Ω<br />

DINPt100Ω<br />

R(PR)<br />

J(IC)<br />

65


TEMPERATURE CONTROLLER<br />

DX SERIES<br />

3TEMPERATURECONTROLLER<br />

[] [] [] []<br />

[] [] [] []<br />

66<br />

PV-displayUnit<br />

SV-displayUnit<br />

Indicator/Controllerselectable<br />

Set<br />

Description<br />

0<br />

Indicator<br />

1<br />

Controller<br />

℃/℉ Selectable<br />

Set<br />

Description<br />

0<br />

℉<br />

1<br />

℃<br />

Decimalmodeselectable<br />

Set<br />

Description<br />

0 Withdecimalmode<br />

1 Withoutdecimalmode<br />

(Outputmodefixed)<br />

Set<br />

Description<br />

0<br />

Currentoutput<br />

1 Relayorvoltage,Pulse<br />

PV-displayUnit<br />

SV-displayUnit<br />

Deviation/Processalarmselectable<br />

Set<br />

Description<br />

0 DeviationSetting<br />

1<br />

ProcessSetting<br />

Alarmmodeselectable<br />

Set<br />

Description<br />

0 Bandalarm(ALH)<br />

1 HighandLowalarm<br />

RetransmissionOutput(PV:250Step):Option<br />

Set<br />

Description<br />

0 Withretransmissionoutput<br />

1 Withoutretransmissionoutput<br />

Holdfunctionofalarmselectable<br />

Set<br />

Description<br />

0 Withholdfunction<br />

1 Withoutholdfunction<br />

PV-<br />

Display<br />

unit<br />

MODEL SUFFIX CODE DESCRIPTION<br />

DX4<br />

DX3<br />

DX2<br />

DX7<br />

DX9<br />

INPUT<br />

(Fixed in order)<br />

K<br />

J<br />

R<br />

P<br />

V<br />

C<br />

CONTROL OUTPUT<br />

(Fixed in order)<br />

ALARM<br />

M<br />

C<br />

S<br />

F<br />

N<br />

S<br />

W<br />

RETRANSMISSION OUTPUT<br />

(Option for DX2, DX3 and<br />

DX9)<br />

CONTROL ACTION<br />

Descriptions<br />

Decimalpoint<br />

position<br />

selection<br />

Input<br />

shiftvalue<br />

Hysteresisof<br />

highalarm(ALH)<br />

Upperlimitof<br />

<strong>temperature</strong><br />

settingrange<br />

Lowerlimitof<br />

<strong>temperature</strong><br />

settingrange<br />

A<br />

M<br />

G<br />

V<br />

Q<br />

N<br />

SV-Display<br />

unit Remark<br />

(Setting range)<br />

Ifyouwant000.0<br />

0~4 set0002onSVdisplayunit<br />

-100~3200<br />

(-199.9~999.9)<br />

-100~3200<br />

(-199.9~999.9)<br />

-100~3200<br />

(-199.9~999.9)<br />

-100~3200<br />

(-199.9~999.9)<br />

■ Model and Suffix code (DX Series)<br />

R<br />

D<br />

48X48mm<br />

96X48mm(Horizontal)<br />

48X96mm(Vertical)<br />

72X72mm<br />

96X96mm<br />

K(CA)<br />

J(IC)<br />

R(PR13%)<br />

P:DINPt100Ω<br />

D:JISPt100Ω<br />

1~5VDC<br />

4~20mADC<br />

Relaycontact<br />

Useforonly<br />

processalarm<br />

RANGE<br />

-50~1,300℃<br />

-50~600℃<br />

0~1,700℃<br />

-199~600℃<br />

0~3,200℃<br />

0~3,200℃<br />

Current(4~20mADC)<br />

SSRdrivepulsevoltage(0/12VDC)<br />

Voltage(0~10VDC)<br />

None(Indicator)<br />

Singlealarm(OnlyforDX4)<br />

Dualalarm(notavailableforDX4)<br />

4~20mADCforProcess-Value<br />

0~10mADCforProcess-Value<br />

0~5VDCforProcess-Value<br />

1~5VDCforProcess-Value<br />

1~10VDCforProcess-Value<br />

None<br />

Reverseactionforheatingcontrol<br />

Directactionforcoolingcontrol