CardioSoft ECG System for rest and exercise - CareFusion.de
CardioSoft ECG System for rest and exercise - CareFusion.de
CardioSoft ECG System for rest and exercise - CareFusion.de
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>CardioSoft</strong> <strong>ECG</strong> <strong>System</strong> <strong>for</strong> <strong>rest</strong> <strong>and</strong> <strong>exercise</strong><br />
Respiratory Diagnostics<br />
• Use as integrated <strong>ECG</strong>, st<strong>and</strong>-alone <strong>exercise</strong> <strong>ECG</strong> or st<strong>and</strong>-alone<br />
<strong>rest</strong>ing <strong>ECG</strong><br />
• Patient data automatically transfers between Vmax ® <strong>and</strong> <strong>CardioSoft</strong> systems<br />
• 15-channel <strong>ECG</strong> capability<br />
• Advanced <strong>and</strong> exp<strong>and</strong>ed data export <strong>and</strong> sharing options<br />
• Cubic Spline <strong>and</strong> Finite Residual Filtering (FRF) provi<strong>de</strong> high quality baseline<br />
correction <strong>and</strong> artifact resolution without sacrificing ST measurements<br />
• On-screen <strong>ECG</strong> measurements provi<strong>de</strong> paperless workflow, or hard copy<br />
print real-time during a test or post-test, when required<br />
GE Marquette’s <strong>CardioSoft</strong> 12-Lead Resting <strong>ECG</strong> <strong>and</strong> Exercise Stress Testing <strong>System</strong><br />
seamlessly integrates with the <strong>CareFusion</strong> Vmax ® system to provi<strong>de</strong> you with<br />
the most comprehensive means to differentiate the cause of exertional dyspnea.<br />
<strong>CardioSoft</strong>’s small acquisition module easily connects to the Vmax ® computer by a<br />
st<strong>and</strong>ard USB port. Arrhythmia Detection (Annotation <strong>and</strong> Classification) <strong>and</strong> Full<br />
Disclosure assist in documenting <strong>and</strong> saving all valuable data. <strong>CardioSoft</strong> data can<br />
be exported to Word <strong>and</strong> Excel <strong>for</strong>mats. Additionally, all data shared with the Vmax ®<br />
system remains in the Vmax ® database.<br />
• View arrhythmias <strong>and</strong> ST segment changes during measurement<br />
• Flexible report <strong>for</strong>mats enable you to choose those you find most useful<br />
• On-screen interpretative statements make your post-test analysis faster<br />
<strong>and</strong> easier<br />
• T-wave alternans <strong>de</strong>scribe the <strong>ECG</strong> pattern specific to the cardiac<br />
repolarization that results in an alternation of the T-wave morphology<br />
on an every-other-beat basis
Signal processing<br />
<strong>ECG</strong> analysis frequency<br />
ST measurements<br />
500 Hz<br />
ST amplitu<strong>de</strong>s, slopes, integral, in<strong>de</strong>x, ST/HR loops, ST/HR<br />
in<strong>de</strong>x up to 15 leads<br />
E, J, <strong>and</strong> post-J point Manual or computer selected<br />
Signal processor<br />
technique<br />
Baseline correction<br />
QRS <strong>de</strong>tection <strong>and</strong><br />
analysis<br />
<strong>ECG</strong> output<br />
Reanalysis<br />
Data acquisition<br />
Technology<br />
Sampling rate<br />
Dynamic range<br />
Resolution<br />
Noise<br />
<strong>ECG</strong> analysis frequency<br />
Incremental median updating<br />
Cubic spline or Finite Residual Filter algorithm<br />
Based on automatic or manual lead selection<br />
Real-time <strong>ECG</strong>/QRS beep/ITL synchronized output<br />
Post-test medians measurements from E, J <strong>and</strong> post-J point<br />
selections<br />
Active, “Type BF” floating isolated powered 14 channel<br />
acquisition module with built-in lead-fail <strong>de</strong>tection <strong>and</strong><br />
lead prep impedance measurement<br />
Over sampling at 4000 Hz, 12 leads<br />
320 mV, + - 10mV signal superimposed on<br />
+<br />
- 150 mV DC offset<br />
4.88 uV/LSB at 500 Hz<br />
140 dB (123 dB with AC filter disabled)<br />
>10 M Ohms at 10 Hz, <strong>de</strong>fibrillator protected<br />