BILL OF QUANTITIES

BILL OF QUANTITIES BILL OF QUANTITIES

12.04.2015 Views

DESIGN AND BUILD SERVICES FOR THE CLARK 230 KV POWER TRANSMISSION LINE PROJECT - PHASE 3B ITEM DESCRIPTION QTY UNIT UNIT COST AMOUNT i. Storage Batteries 1 lot j. Battery Charger 1 lot k. MBSC 1 lot l. CCTV 1 lot m. Substation Protection System 1 lot n. Line Protection System 1 lot o. Network Disturbance Monitoring 1 lot p. Fibre Optical Terminal Equipment 1 lot q. Protection Signaling Equipment 1 lot r Microwave Radio Telephone equipment 1 lot Clark Load End Substation at PSPC A36 Station Service Transformer 75 kva 22.9/0.23kV, three 2 lot phase, Outdoor ONAN type, 35 kV xlpe cable, 300:5 amp 22.9 kV CT, and accessories in accordance to the requirements of the Technical Data Sheet (TDS). To includes bus bar modification, current transformer, cover, support and wiring/termination to substation protection system. The scope covers the construction of foundation, HV and LV wiring and installation of new transformer. A37 Distribution Board 3 Phase 230 VAC with enclosure , 2 sets main breaker, tie breaker, automatic transfer switch, four (4) 3 poles branch circuit breakers, assorted copper wires, conduits and accessories in accordance to the requirements of the Technical Data Sheet (TDS). The scope includes the wiring and termination to existing MTS/AC panel and fire suppression panel. SUB-TOTAL FOR ITEM 3A ELECTRICAL WORKS B CIVIL WORKS FURNISH, INSTALL, CONSTRUCT, PLACE, APPLY AND / OR LAY, INCLUDING FURNISHING OF PLANT, LABOR, EQUIPMENT AND MATERIALS B1 EQUIPMENT FOUNDATION Consisting of concrete (211kg/cm²), Non-shirk Grout, Reinforcing Steel Bars (Grade 275), Excavation and backfill, Leveling Concrete (141 kg/cm²) and other incidentals required to complete the works. a. Power Transformer 2 lot b. Power Circuit Breaker 12 lot c. Current Transformer 72 lot d. Voltage Transformer 12 lot e. Surge Arresters 24 lot f. Ganged Disconnect Switch 24 lot G. Bus Supports 48 lot f. Emergency Generator set 1 lot B2 230 kV Gantry Structure Foundation Consisting of concrete (211kg/cm²), Non-shirk Grout, Reinforcing Steel Bars (Grade 275), Excavation and backfill, Leveling Concrete (141 kg/cm²) and other incidentals required to complete the works. 1 lot Page 8 of 15

DESIGN AND BUILD SERVICES FOR THE CLARK 230 KV POWER TRANSMISSION LINE PROJECT - PHASE 3B ITEM DESCRIPTION QTY UNIT UNIT COST AMOUNT B3 Roadways, Parking Area, Concrete Curve & Gutter, 2227 sq.m Open stock yard Construction of access road from the existing roadway to the transformer area and parking area at warehouse, consisting of Concrete Pavement (246kg/cm²), Curb and Gutter (211kg/cm²) including dowels, Reinforcing steel bars (Grade 275), Aggregate Sub-Base and other incidentals to complete the work. B4 Drainage System - Consisting of different sizes of 435 lm RCDP, Drainage Appurtenances consisting of Concrete (Main) (211kg/cm²), Reinforcing steel bars Grade 275, Excavation and backfill, Miscellaneous Steel (ASTM 300 lm A36), CHB including demolition/restoration works for the (Sec.) affected portion of the existing drainage appurtenances and other incidentals to complete the work. B5 Oil/Water Separator - Consisting of concrete 1 lot (211kg/cm²), Reinforcing Steel Bars (Grade 275), Excavation and backfill, Miscellaneous Steel, Galvanized Steel pipe, B.I. Pipe, including its tapping to the nearest drainage system and other incidentals required to complete the work. B6 Concrete Firewall - Between transformers consisting of 1 lot Concrete (211kg/cm²), Reinforcing Steel Bars (Grade 275), Excavation and Backfill, Leveling Concrete (141kg/cm²) and other incidentals required to complete the work. B7 Cable Trenches - Consisting of Concrete (211kg/cm²) 400 l.m. Reinforcing Steel Bars (Grade 275), Excavation, leveling (Main) Concrete (141kg/cm²), Checkered Steel Plate Cover, Stiffener, Embedded Metals, Steel angle, galvanized cable tray, pits, Discharge Pipes including 200 l.m. demolition/restoration works for the affected portion of (Branches) the existing cable trench to connect the new cable trench and other incidentals to complete the work. B8 Cable Pipe Crossing Roadways - Consisting of 12 l.m. concrete (211kg/cm²), Reinforcing Steel Bars (Grade 275) Excavation, Sand and Gravel bedding, uPCV Pipes, Discharge Pipes and other incidentals required to complete the works. B9 Switchyard Gravel Surfacing - Gravel surfacing on the 1200 cu.m bays where the equipment will be installed with the lines and extent as directed by the owner. B10 Seclusion Fence and Gate - Enclosing the 230kV and 235 l.m. 69kV switchyard consisting of Hot Dipped Galvanized Wire Mesh Gauge #10, G.I. Pipes Schedule 40, Miscellaneous Steel (ASTM A36), Concrete (211 kg/cm²) Reinforcing Steel Bars (Grade 275), Excavation and Backfill, and other incidentals to complete the work. B11 Embankment of Substation Expansion Area - 7040 sq.m. Consisting of clearing, grading, and embankment with compaction in layers to match the existing finish grade in accordance with DPWH Standard Specifications. Page 9 of 15

DESIGN AND BUILD SERVICES FOR THE CLARK 230 KV POWER TRANSMISSION LINE PROJECT -<br />

PHASE 3B<br />

ITEM DESCRIPTION<br />

QTY UNIT UNIT COST AMOUNT<br />

i. Storage Batteries 1 lot<br />

j. Battery Charger 1 lot<br />

k. MBSC 1 lot<br />

l. CCTV 1 lot<br />

m. Substation Protection System 1 lot<br />

n. Line Protection System 1 lot<br />

o. Network Disturbance Monitoring 1 lot<br />

p. Fibre Optical Terminal Equipment 1 lot<br />

q. Protection Signaling Equipment 1 lot<br />

r Microwave Radio Telephone equipment 1 lot<br />

Clark Load End Substation at PSPC<br />

A36 Station Service Transformer 75 kva 22.9/0.23kV, three 2 lot<br />

phase, Outdoor ONAN type, 35 kV xlpe cable, 300:5<br />

amp 22.9 kV CT, and accessories in accordance to the<br />

requirements of the Technical Data Sheet (TDS). To<br />

includes bus bar modification, current transformer, cover,<br />

support and wiring/termination to substation protection<br />

system. The scope covers the construction of<br />

foundation, HV and LV wiring and installation of new<br />

transformer.<br />

A37 Distribution Board 3 Phase 230 VAC with enclosure , 2 sets<br />

main breaker, tie breaker, automatic transfer switch, four<br />

(4) 3 poles branch circuit breakers, assorted copper<br />

wires, conduits and accessories in accordance to the<br />

requirements of the Technical Data Sheet (TDS). The<br />

scope includes the wiring and termination to existing<br />

MTS/AC panel and fire suppression panel.<br />

SUB-TOTAL FOR ITEM 3A ELECTRICAL WORKS<br />

B CIVIL WORKS<br />

FURNISH, INSTALL, CONSTRUCT, PLACE, APPLY<br />

AND / OR LAY, INCLUDING FURNISHING <strong>OF</strong> PLANT,<br />

LABOR, EQUIPMENT AND MATERIALS<br />

B1 EQUIPMENT FOUNDATION Consisting of concrete<br />

(211kg/cm²), Non-shirk Grout, Reinforcing Steel Bars<br />

(Grade 275), Excavation and backfill, Leveling Concrete<br />

(141 kg/cm²) and other incidentals required to complete<br />

the works.<br />

a. Power Transformer 2 lot<br />

b. Power Circuit Breaker 12 lot<br />

c. Current Transformer 72 lot<br />

d. Voltage Transformer 12 lot<br />

e. Surge Arresters 24 lot<br />

f. Ganged Disconnect Switch 24 lot<br />

G. Bus Supports 48 lot<br />

f. Emergency Generator set 1 lot<br />

B2 230 kV Gantry Structure Foundation Consisting of<br />

concrete (211kg/cm²), Non-shirk Grout, Reinforcing Steel<br />

Bars (Grade 275), Excavation and backfill, Leveling<br />

Concrete (141 kg/cm²) and other incidentals required to<br />

complete the works.<br />

1 lot<br />

Page 8 of 15