PBS 140 Child Care Center Design Guide - The Whole Building ...
PBS 140 Child Care Center Design Guide - The Whole Building ...
PBS 140 Child Care Center Design Guide - The Whole Building ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CHAPTER 10: TECHNICAL CRITERIA<br />
10.11 Electrical<br />
Safety of the children and expansion of future electrical needs must be<br />
considered. All data, equipment, and communication requirements must<br />
be defined in advance to prevent inadequate facilities. Consult with GSA<br />
and center staff when defining needs.<br />
10.11.1 Requirements:<br />
Provide power supply as prescribed in the latest edition of GSA Facilities<br />
Standards for the Public <strong>Building</strong>s Service for TV, VCR, AV equipment,<br />
telephones, and computers for staff and children’s areas.<br />
� Except in areas with cabinets above counters, mount receptacles at<br />
1370 mm above the finished floor. All receptacles shall be pediatric<br />
type.<br />
� Provide wall duplex outlets at approximately 4000 mm on center.<br />
� Provide one duplex outlet per wall on walls less than 3000 mm.<br />
� Provide electrical power outlets for kitchen and laundry areas for refrigerator,<br />
oven, range, freezer, convection oven, microwave oven, garbage<br />
disposal, and washer/dryer units as required. Provide power supplies<br />
where under counter appliances will be located.<br />
� Install closed circuit TV camera(s) at each entrance/exit and at play<br />
yards as determined by the GSA security risk analysis.<br />
� Provide for a possible additional monitor location in the staff area.<br />
� Coordinate requirements and provide for installation of: electrically<br />
switched doors, security alarm, and intercom systems.<br />
10-12<br />
<strong>PBS</strong>-<strong>140</strong> - July 2003