04.04.2015 Views

RULES OF - Cobb & Douglas Public Health

RULES OF - Cobb & Douglas Public Health

RULES OF - Cobb & Douglas Public Health

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

290-5-14-.05 Equipment and Utensils. Amended. (4) Location and Installation.<br />

(4) Location and Installation.<br />

(a) Equipment, Clothes Washers and Dryers, and Storage Cabinets,<br />

Contamination Prevention.<br />

1. Except as specified in 2 of this subsection, equipment, a cabinet used for the storage of food, or<br />

a cabinet that is used to store cleaned and sanitized equipment, utensils, laundered linens, and singleservice<br />

and single-use articles may not be located under any source of contamination, including in<br />

locker rooms ; in toilet rooms; in garbage rooms; in mechanical rooms; under sewer lines; under<br />

leaking water lines including leaking automatic fire sprinkler heads or under lines on which water has<br />

condensed; or under open stairwells.<br />

2. A storage cabinet used for linens or single-service or single-use articles may be stored in a<br />

locker room.<br />

3. If a mechanical clothes washer or dryer is provided, it shall be located so that the washer or<br />

dryer is protected from contamination and only where there is no exposed food; clean equipment,<br />

utensils, and linens; and unwrapped single-service and single-use articles.<br />

(b) Fixed Equipment, Spacing or Sealing.<br />

1. Equipment that is fixed because it is not easily movable shall be installed so that it is:<br />

(i) Spaced to allow access for cleaning along the sides, behind, and above the equipment;<br />

(ii) Spaced from adjoining equipment, walls, and ceilings a distance of not more than one<br />

thirty-second inch or 1 millimeter; or<br />

(iii) Sealed to adjoining equipment or walls, if the equipment is exposed to spillage or seepage.<br />

2. Table-mounted equipment that is not easily movable shall be installed to allow cleaning of the<br />

equipment and areas underneath and around the equipment by being:<br />

(i) Sealed to the table; or<br />

(ii) Elevated on legs that provide at least a 4 inch (10 centimeter) clearance between the table<br />

and the equipment.<br />

(c) Fixed Equipment, Elevation or Sealing.<br />

1. Except as specified in 2 and 3 of this subsection, floor-mounted equipment that is not easily<br />

movable shall be sealed to the floor or elevated on legs that provide at least a 6 inch (15 centimeter)<br />

clearance between the floor and the equipment.<br />

<strong>Cobb</strong> and <strong>Douglas</strong> County <strong>Public</strong> <strong>Health</strong><br />

<strong>Douglas</strong> Food Service Code<br />

91

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!