290-5-14-.05 Equipment and Utensils. Amended. (4) Location and Installation.<br />
(4) Location and Installation.<br />
(a) Equipment, Clothes Washers and Dryers, and Storage Cabinets,<br />
Contamination Prevention.<br />
1. Except as specified in 2 of this subsection, equipment, a cabinet used for the storage of food, or<br />
a cabinet that is used to store cleaned and sanitized equipment, utensils, laundered linens, and singleservice<br />
and single-use articles may not be located under any source of contamination, including in<br />
locker rooms ; in toilet rooms; in garbage rooms; in mechanical rooms; under sewer lines; under<br />
leaking water lines including leaking automatic fire sprinkler heads or under lines on which water has<br />
condensed; or under open stairwells.<br />
2. A storage cabinet used for linens or single-service or single-use articles may be stored in a<br />
locker room.<br />
3. If a mechanical clothes washer or dryer is provided, it shall be located so that the washer or<br />
dryer is protected from contamination and only where there is no exposed food; clean equipment,<br />
utensils, and linens; and unwrapped single-service and single-use articles.<br />
(b) Fixed Equipment, Spacing or Sealing.<br />
1. Equipment that is fixed because it is not easily movable shall be installed so that it is:<br />
(i) Spaced to allow access for cleaning along the sides, behind, and above the equipment;<br />
(ii) Spaced from adjoining equipment, walls, and ceilings a distance of not more than one<br />
thirty-second inch or 1 millimeter; or<br />
(iii) Sealed to adjoining equipment or walls, if the equipment is exposed to spillage or seepage.<br />
2. Table-mounted equipment that is not easily movable shall be installed to allow cleaning of the<br />
equipment and areas underneath and around the equipment by being:<br />
(i) Sealed to the table; or<br />
(ii) Elevated on legs that provide at least a 4 inch (10 centimeter) clearance between the table<br />
and the equipment.<br />
(c) Fixed Equipment, Elevation or Sealing.<br />
1. Except as specified in 2 and 3 of this subsection, floor-mounted equipment that is not easily<br />
movable shall be sealed to the floor or elevated on legs that provide at least a 6 inch (15 centimeter)<br />
clearance between the floor and the equipment.<br />