15.11.2012 Views

Diving Equipment Authorized for U.S. Navy Use (ANU)

Diving Equipment Authorized for U.S. Navy Use (ANU)

Diving Equipment Authorized for U.S. Navy Use (ANU)

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Category/<br />

Control #<br />

Item/Stock<br />

Number<br />

5.3 4500 and 3000 PSIG H. P. AIR COMPRESSORS(cont.)<br />

CAT I<br />

5.3.18<br />

H.P.<br />

COMPRESSOR<br />

COMMERCIAL<br />

NSN 9C4310-01-<br />

107-8006<br />

Manufacturer Designation/Model Notes & comments<br />

MAKO KA7-DA<br />

HP COMPRESSOR<br />

3000 PSI 5 SCFM<br />

5.4 MEDIUM AND LOW PRESSURE AIR COMPRESSORS<br />

CAT I<br />

5.4.1<br />

CAT I<br />

5.4.2<br />

CAT I<br />

5.4.3<br />

CAT I<br />

5.4.4<br />

MP AIR<br />

COMPRESSOR,<br />

7H-4310-01-316-<br />

0406<br />

MP AIR<br />

COMPRESSOR,<br />

9C-4310-01-098-<br />

6833<br />

APL: 061500062<br />

LP AIR<br />

COMPRESSOR,<br />

COMMERCIAL<br />

LP AIR<br />

COMPRESSOR,<br />

COMMERCIAL<br />

RIX 2JS2B-300<br />

400 PSI, 150 SCFM<br />

QUINCY 5120, W-5120LPH<br />

250 PSIG, 87 SCFM<br />

AQUA AIR AA1 325<br />

200 PSIG, 18 SCFM<br />

ATLAS COPCO 18LT8BE200 PSIG, 20<br />

SCFM<br />

GENERAL NOTES APPLY<br />

GENERAL NOTES APPLY.<br />

COMPRESSOR IS OIL FREE<br />

DESIGN.<br />

GENERAL NOTES APPLY. NO<br />

LONGER M<strong>ANU</strong>FACTURED BUT<br />

AUTHORIZED FOR CONTINUED<br />

USE AND WILL CONTINUE TO BE<br />

SUPPORTED BY<br />

M<strong>ANU</strong>FACTURER.<br />

GENERAL NOTES APPLY. MAY BE<br />

USED WITH SEA 00C WRITTEN<br />

APPROVAL.<br />

GENERAL NOTES APPLY.<br />

SECTION 006 - AIR PURIFICATION SYSTEMS, AIR FILTERS & FILTER<br />

ELEMENTS<br />

6.1 COMPRESSOR AIR PURIFICATION SYSTEMS<br />

6.2 AIR FILTRATION SYSTEMS AND FILTER ELEMENTS<br />

6.3 SODALIME CARBON DIOXIDE ABSORBENTS<br />

6.1 COMPRESSION AIR PURIFICATION SYSTEMS<br />

NOTE: FAILURE TO PERFORM M<strong>ANU</strong>FACTURER REQUIRED MAINTENANCE CAN RESULT IN PREMATURE DLSS<br />

COMPONENT FAILURES AND POSSIBLY CAUSE DIVER<br />

CAT I<br />

6.1.1<br />

CAT I<br />

6.1.2<br />

CAT I<br />

6.1.3<br />

CAT I<br />

6.1.4<br />

CAT I<br />

6.1.5<br />

PURIFICATION<br />

SYSTEM,<br />

COMMERCIAL<br />

PURIFICATION<br />

SYSTEM,<br />

COMMERCIAL<br />

PURIFICATION<br />

SYSTEM,<br />

COMMERCIAL<br />

PURIFICATION<br />

SYSTEM,<br />

COMMERCIAL<br />

PURIFICATION<br />

SYSTEM,<br />

COMMERCIAL<br />

MAKO MK-420-C 300,000 FT3 @ 800F,80 CFM @<br />

6000 PSI<br />

BAUER P-10 140,000 FT3 @ 700F,35-40 CFM @<br />

5000 PSI<br />

MAKO MK 10-C 120,000 FT3 @ 800F,40 CFM @<br />

6000 PSI<br />

BAUER P-5 90,000 FT3 @ 700F,35-40 CFM @<br />

5000 PSI<br />

MAKO MK-8-C 83,000 FT3 @ 800F,40 CFM @6000<br />

PSI