Section 2 - Instrumentation For Models: JGH:E:K:T<br />

DNFT Installation<br />

1. Loosen the Allen set screws on the DNFT and remove<br />

magnet housing. Do not remove magnet, spring, or spacer<br />

from magnet housing.<br />

2. Remove piston enclosure plug from end of desired divider<br />

valve. The DNFT installs on any of the divider valves of the<br />

divider block. The DNFT requires the correct magnet<br />

assembly to match the divider valve manufacturer (see<br />

Fig. 2-6).<br />

NOTE: Do not install a DNFT on Lincoln divider valves<br />

with cycle indicator pins.<br />

3. If applicable, verify o-ring or metal gasket is in place on<br />

magnet housing. Thread magnet housing into end of<br />

divider valve. Torque to 15 foot pounds maximum.<br />

4. Slide DNFT all the way onto hex of magnet housing.<br />

Torque Allen set screws on hex of magnet housing to 25<br />

inch pounds, maximum.<br />

5. The LED on the DNFT indicates each divider valve cycle to allow lubricator pump adjustment for<br />

<strong>Ariel</strong> recommended cycle time and oil consumption. If the LED fails to blink during compressor<br />

operation or by manually pumping oil into the divider valve, then the DNFT requires adjustment.<br />

6. The divider valve must cycle during<br />

DNFT adjustment. To cycle it, either<br />

run the compressor or manually pump<br />

oil through the distribution block with a<br />

hand priming pump.<br />

1 2 3 4<br />

5 6 7<br />

8<br />

7. To adjust, slide DNFT all the way onto<br />

hex of magnet housing. Tighten Allen<br />

set screws to 25 inch pounds maxi-<br />

12S<br />

mum. A blinking LED indicates correct<br />

adjustment. If the LED fails to blink<br />

with divider valve cycling, slide DNFT<br />

12T 9<br />

back on the hex of the magnet housing<br />

in 1/16" increments until it does.<br />

10<br />

8. Make all conduit and connections<br />

appropriate for area classification.<br />

Support conduit and fittings to avoid<br />

bending the magnet housing.<br />

9. After DNFT installation and before<br />

compressor start-up, purge all air from<br />

divider block lubrication system with a<br />

purge gun.<br />

1. Divider Valve Piston<br />

2. Magnet<br />

3. Magnet Housing<br />

4. O-Ring<br />

5. Allen Set Screws (2)<br />

SBCO & Trabon O-Ring Seal 7/16”-20<br />

Trabon Metal Gasket Seal 7/16”-20<br />

(1994 or earlier)<br />

Lincoln O-Ring Seal 7/16”-20<br />

Extended Nose<br />

FIGURE 2-6 Typical DNFT Magnet<br />

Assemblies<br />

6. LED<br />

7. Control Housing<br />

8. Wire Leads (7)<br />

9. Divider Valve<br />

10. Piston Enclosure Plug<br />

FIGURE 2-7 Typical DNFT Installation<br />

NOTE: When installing multiple DNFTs, wire each to a separate alarm circuit of the control<br />

panel, annunciator, or PLC to simplify lubrication system and DNFT troubleshooting.<br />

PAGE 2-8 3/11