Section 2 - Instrumentation For Models: JGH:E:K:T<br />
Proflo Jr. No-Flow Switch<br />
CAUTION: See arc welding caution at the beginning of this chapter.<br />
Proflo Jr. Installation<br />
CAUTION: Explosion hazard - no user serviceable parts. Do not disconnect wiring while<br />
circuit is live. Complete all field wiring in accordance with local codes pertaining to<br />
potentially explosive atmospheres. Do not open battery compartment in areas known to<br />
contain explosive gases.<br />
1. Loosen the two Allen head set<br />
screws on top of Proflo Jr. case<br />
and remove magnet housing.<br />
Do not remove magnet, spring,<br />
and spacer from magnet housing.<br />
2. Remove piston end plug from<br />
desired divider valve. The Proflo<br />
Jr. installs on either side of<br />
any divider valve, but requires<br />
the correct magnet housing for<br />
each divider valve manufacturer<br />
(Trabon, Dropsa, etc.).<br />
NOTE: Do not install the Proflo<br />
Jr. on any divider valves<br />
with cycle indicator pins.<br />
3. Verify O-ring is in place on magnet<br />
housing. Thread magnet<br />
housing into end of divider<br />
valve. Torque magnet housing<br />
to 15 foot-pounds max.<br />
1. Magnet Housing<br />
2. O-Ring<br />
3. Allen Head Set<br />
Screw (2)<br />
4. Proflo Jr. Case<br />
4. Slide Proflo Jr. all the way onto magnet housing. Torque Allen head set screws to 15 inch-pounds<br />
max. DO NOT over tighten set screws.<br />
5. The LED on the Proflo Jr. indicates one complete cycle of the divider valve system. Verify correct<br />
operation by pumping oil through the divider valve assembly. The force feed lubricator data plate<br />
on the lubricator box indicates either normal and break-in cycle times at maximum rated speed,<br />
or normal cycle time for applied speed. Use break-in cycle times only for the first 200 hours of<br />
operation before changing to the normal cycle time. If unable to determine cycle time, contact the<br />
<strong>Ariel</strong> Response Center.<br />
6. For Lincoln divider valves it may be necessary to adjust the Proflo Jr. by sliding it back about 1/8”<br />
on the magnet housing until the LED flashes. All conduit and connections should be appropriate<br />
for area classification. Use flexible conduit to ease installation. Support conduit and fittings to<br />
minimize vibration.<br />
7. After Proflo Jr. installation or performance of any maintenance on the lube system, compressor<br />
cylinders, or packing, pre-lube the complete system with a purge gun to purge air from the<br />
divider valves and all components BEFORE COMPRESSOR START-UP.<br />
PAGE 2-6 3/11<br />
12S<br />
12T<br />
1 2 3 4<br />
13<br />
14<br />
5<br />
5. LED<br />
6. Red Wire Leads (2)<br />
7. Orange Wire Leads (2)<br />
8. Yellow Wire Leads (2)<br />
9. Green Wire Lead (1)<br />
12 11<br />
FIGURE 2-4 Proflo Jr. Installation<br />
10. Battery Plug<br />
11. Grounding Lug<br />
12. Battery<br />
13. Divider Valve<br />
14. End Plug<br />
6<br />
7<br />
8<br />
9<br />
10