01.04.2015 Views

Access Virus User Manual - SoundProgramming.Net

Access Virus User Manual - SoundProgramming.Net

Access Virus User Manual - SoundProgramming.Net

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ACCESS VIRUS OS4 31<br />

The Second Filter<br />

Yet another experiment in which<br />

you can come up new filtering<br />

characteristics that are typical of<br />

the <strong>Virus</strong>:<br />

Set the FILTER BALANCE pot to the<br />

center position (12 o’clock) and<br />

CUTOFF 2 to the maximum level.<br />

The FILTER ROUTING operating<br />

mode must remain SER 6. Set CUT-<br />

OFF and RESONANCE to a middle<br />

value and select a clearly audible<br />

SATURATION curve.<br />

Now you can filter this complex<br />

signal produced by a combination<br />

of the saturation stage and the<br />

Filter-1 yet again. Rotate the CUT-<br />

OFF 2 pot slowly towards the center<br />

position (12 o’clock). You can<br />

hear how Filter-2 gradually modifies<br />

the distorted signal. You can<br />

set a RESONANCE value for Filter-2<br />

if you press the FILT 2 SELECT button<br />

and rotate the RESONANCE pot<br />

to the desired position. Set the<br />

CUTOFF 2 pot to a position to the<br />

right of the center position. This<br />

configuration can be described as a<br />

complex non-linear filter set up<br />

where the cutoff frequency is controlled<br />

via the CUTOFF pot. You can<br />

dial in a wide range of sound-shaping<br />

option via CUTOFF 2. Also try<br />

modifying the resonances of both<br />

filters as well as the SATURATION<br />

curve to come up with different filtering<br />

characteristics.<br />

Now experiment with the diverse<br />

filter modes and listen closely to<br />

the effect of the parameters RESO-<br />

NANCE, ENV AMOUNT and KEY<br />

FOLLOW in conjunction with the<br />

SELECT button. Please also keep in<br />

mind that the chances of choking a<br />

sound off are substantially greater<br />

when you are using both filters:<br />

For instance, if the first filter is<br />

used as a low pass with a low cutoff<br />

frequency and the second as a<br />

high pass with a high cutoff frequency,<br />

the <strong>Virus</strong> will not generate<br />

an audible signal when you set the<br />

FILTER BALANCE pot to the center<br />

position (12 o’clock).<br />

Regardless of which FILTER<br />

ROUTING option you chose, the<br />

SATURATION stage is always post-<br />

Filter-1, i.e. after Filter in the signal<br />

chain.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!