252 CHAPTER 24<br />
Appendix<br />
SYSTEM EXCLUSIVE<br />
DATA<br />
VIRUS MIDI SYSTEM EXCLU-<br />
SIVE IMPLEMENTATION<br />
The Parameters of the VIRUS are<br />
organized in three so-called pages<br />
A, B and C. Each page contains 128<br />
parameters, addressed by numbers<br />
from 0 to 127. Each parameter is<br />
represented by one byte with a<br />
maximum value of 127. All parameters<br />
are individually accessible by<br />
SysEx-Parameterchange.<br />
The pages A and B represent a Single-Program,<br />
thus a Single-Program<br />
contains 256 Bytes.<br />
Page A (LowPage) contains Single<br />
parameters that are usefull for<br />
MIDI automation. The parameters<br />
of this page are additionally controllable<br />
by MIDI Control Change.<br />
The sending and reception of MIDI<br />
Control Change can be enabled or<br />
disabled by MIDI CONTROL Low-<br />
Page (CTRL menu). When disabled<br />
(LowPage=SysEx), the VIRUS only<br />
sends and receives SysEx Parameter<br />
Change on Page A. When<br />
enabled (LowPage=Contr), the<br />
VIRUS sends MIDI Control Change<br />
on parameter movement,<br />
and receives both MIDI Control<br />
Change and SysEx-Parameterchange<br />
on Page A.<br />
The default setting is Low-<br />
Page=Contr.<br />
The remaining Single parameters<br />
in Page B (HiPage) are additionally<br />
controllable by MIDI Polyphonic<br />
Pressure (!). The send and reception<br />
of MIDI Poly Pressure can be<br />
enabled or disabled by MIDI CON-<br />
TROL HiPage (CTRL menu).<br />
When disabled (HiPage=SysEx),<br />
the VIRUS only sends and receives<br />
SysEx Parameter Change on Page<br />
B. When enabled (HiPage=PolyPrs),<br />
the VIRUS sends MIDI Poly Pressure<br />
on parameter movements, and<br />
receives both MIDI Poly Pressure<br />
and SysEx Parameter Change on<br />
Page B. This feature should not be<br />
used in connection with a keyboard<br />
that sends Polyphonic Pressure.<br />
The default setting is<br />
HiPage=SysEx.