252 CHAPTER 24<br />

Appendix<br />

SYSTEM EXCLUSIVE<br />

DATA<br />

VIRUS MIDI SYSTEM EXCLU-<br />

SIVE IMPLEMENTATION<br />

The Parameters of the VIRUS are<br />

organized in three so-called pages<br />

A, B and C. Each page contains 128<br />

parameters, addressed by numbers<br />

from 0 to 127. Each parameter is<br />

represented by one byte with a<br />

maximum value of 127. All parameters<br />

are individually accessible by<br />

SysEx-Parameterchange.<br />

The pages A and B represent a Single-Program,<br />

thus a Single-Program<br />

contains 256 Bytes.<br />

Page A (LowPage) contains Single<br />

parameters that are usefull for<br />

MIDI automation. The parameters<br />

of this page are additionally controllable<br />

by MIDI Control Change.<br />

The sending and reception of MIDI<br />

Control Change can be enabled or<br />

disabled by MIDI CONTROL Low-<br />

Page (CTRL menu). When disabled<br />

(LowPage=SysEx), the VIRUS only<br />

sends and receives SysEx Parameter<br />

Change on Page A. When<br />

enabled (LowPage=Contr), the<br />

VIRUS sends MIDI Control Change<br />

on parameter movement,<br />

and receives both MIDI Control<br />

Change and SysEx-Parameterchange<br />

on Page A.<br />

The default setting is Low-<br />

Page=Contr.<br />

The remaining Single parameters<br />

in Page B (HiPage) are additionally<br />

controllable by MIDI Polyphonic<br />

Pressure (!). The send and reception<br />

of MIDI Poly Pressure can be<br />

enabled or disabled by MIDI CON-<br />

TROL HiPage (CTRL menu).<br />

When disabled (HiPage=SysEx),<br />

the VIRUS only sends and receives<br />

SysEx Parameter Change on Page<br />

B. When enabled (HiPage=PolyPrs),<br />

the VIRUS sends MIDI Poly Pressure<br />

on parameter movements, and<br />

receives both MIDI Poly Pressure<br />

and SysEx Parameter Change on<br />

Page B. This feature should not be<br />

used in connection with a keyboard<br />

that sends Polyphonic Pressure.<br />

The default setting is<br />

HiPage=SysEx.