Non-Mining MSGP 2010 General Permit<br />

All Units<br />

Benchmark Values (mg/L, total)<br />

mg/L Cadmium Copper Lead Nickel Silver Zinc<br />

175-200 0.0447 0.0447 0.2873 7.475 0.0106 2.001<br />

200-225 0.0501 0.0500 0.3255 8.258 0.0130 2.211<br />

225-250 0.0555 0.0552 0.3637 9.028 0.0156 2.417<br />

250-275 0.0609 0.0601 0.4020 9.786 0.0183 2.620<br />

275-300 0.0663 0.0655 0.4402 10.53 0.0213 2.821<br />

300-325 0.0714 0.0706 0.4784 11.27 0.0244 3.019<br />

325-350 0.0770 0.0757 0.5166 12.00 0.0278 3.214<br />

350-375 0.0823 0.0800 0.5547 12.72 0.0312 3.408<br />

375-400 0.0876 0.0859 0.5927 13.44 0.0349 3.599<br />

How to Determine Hardness for Hardness-Dependent Parameters.<br />

The permittee shall monitor stormwater discharges for parameters specified in Part 8 for the primary<br />

industrial activity, and any co-located industrial activities authorized under this permit. If any of the<br />

parameters are hardness-dependent, the permittee must also characterize for hardness. The results of<br />

the general analytical monitoring, including hardness, shall be submitted to ADEQ in accordance with<br />

Part 7. For discharges to:<br />

<br />

<br />

Perennial or intermittent waters, the hardness shall be of the surface water receiving the<br />

discharge.<br />

Ephemeral waters, the hardness shall be of the discharge leaving the facility.<br />

Hardness characterization of the receiving water shall include analysis of samples from the surface water<br />

receiving the discharge or surface water data collected by a third party provided the data is credible,<br />

scientifically defensible and is representative of current conditions. The data and the methodology for<br />

determining the hardness values must be submitted to ADEQ in the first year of permit coverage to allow<br />

ADEQ to compare monitoring results with applicable water quality standards. The permittee shall retain all<br />

reports and monitoring data in accordance with Part 7.5 of the permit.<br />