Transceiver<br />

189, Rue d'Aubervilliers C.P. 97 75886 PARIS Cedex 18 FRANCE<br />

Tél : 33 (0)1.44.65.65.00 Fax : 33 (0)1.44.65.65.10<br />

http://www.balogh-group.com<br />

TLE B891/PUR<br />

IDENTIFICATION SYSTEMS<br />

DESCRIPTION _____________________________________________________________________________________________<br />

The TLE B891/PUR is a compact transceiver used to read the OF tags or read/write to the<br />

OMA (MEGA .ID range) or GIE (MID .ID range) tags.<br />

It is fitted with a shielded cord ending by an M12 plug which enables a quick connection to the<br />

<strong>Balogh</strong> control board.<br />

DATA FOR ASSEMBLY ____________________________________________________________________________<br />

The standard TLE B 891/PUR is fitted with a 0.8 m-long PUR cord.<br />

The special TLE B 891/PUR/5m is fitted with a 5 m-long PUR cord.<br />

∅ 5.6 cord<br />

led<br />

two ∅ 4.5 holes<br />

<strong>center</strong> of the sensing side<br />

travel direction<br />

<strong>center</strong> of the sensing side<br />

PINOUT:<br />

Pins Assignment<br />

V 1 +U power supply<br />

S 2 Outlet<br />

E 3 Inlet<br />

O 4 0 V power supply<br />

If an extension (shielded) cord is required, do not exceed 50 m.<br />

Warning : multiplexing the signals would produce damages.<br />

∅ 12 male plug


1234<br />

1234<br />

123<br />

123<br />

C<br />

H<br />

A<br />

R<br />

A<br />

C<br />

T<br />

E<br />

R<br />

I<br />

S<br />

T<br />

I<br />

C<br />

S<br />

T R A N S M I S S I O N<br />

S n<br />

S r<br />

LS<br />

r<br />

S n<br />

S r<br />

LS<br />

r<br />

Parameters<br />

OMA / GIE<br />

711<br />

731<br />

831/ 931<br />

m in. t yp. m in. t yp. m in. t yp. unit<br />

maximum range<br />

23<br />

18<br />

30<br />

mm<br />

recommended<br />

range<br />

t ransmit zone length<br />

@S r<br />

0<br />

0.4<br />

S<br />

mm<br />

n<br />

1)<br />

2)<br />

3)<br />

5 30<br />

55<br />

mm<br />

OF / OFR<br />

71<br />

73<br />

maximum range<br />

20<br />

mm<br />

recommended<br />

range<br />

0.4<br />

S<br />

mm<br />

n<br />

t ransmit zone length<br />

@S r<br />

30<br />

4) mm<br />

Max. allowed offsets for LS r<br />

to be worth the mentioned value :<br />

• angular: ± 20° for any tags<br />

• lateral (mm): 1) ± 8 2) ± 5<br />

3)<br />

± 10<br />

4)<br />

± 5<br />

Electronics<br />

Packaging<br />

min.<br />

n ominal<br />

max.<br />

ambient<br />

temperature<br />

-25<br />

+ 50<br />

° C<br />

voltage<br />

supply<br />

21<br />

24<br />

29<br />

V<br />

protection against<br />

reverse polarity<br />

unit<br />

yes<br />

-<br />

current<br />

supply<br />

@ 24V<br />

60<br />

mA<br />

transmit<br />

frequency<br />

1.<br />

5<br />

MHz<br />

casing<br />

Rilsan<br />

-<br />

protection rating<br />

IP 67<br />

-<br />

weight<br />

85<br />

g<br />

A<br />

S<br />

S<br />

E<br />

M<br />

B<br />

L<br />

Y<br />

The TLEB is not to be mounted directly in a recessed metal cavity: a minimum metalfree<br />

clearance surrounding the tag is required as shown:<br />

123456789<br />

123456789<br />

123456789<br />

1234<br />

1234<br />

1234<br />

1234<br />

15 mm<br />

123456789<br />

123456789<br />

123456789<br />

123<br />

123<br />

123<br />

123<br />

123456<br />

123456<br />

123<br />

1234<br />

123456789<br />

123456789012<br />

123456789<br />

123456789012<br />

123456789<br />

R<br />

123456789<br />

123456789<br />

123456789012<br />

123456789<br />

15 mm<br />

E<br />

15 mm<br />

C<br />

O<br />

90° mounting<br />

sensing side<br />

M<br />

bracket SC 26<br />

M<br />

To avoid interference between two transceivers, there must be a minimum space inbetween<br />

(170 mm):<br />

E<br />

N<br />

D<br />

A<br />

T<br />

I<br />

O<br />

TLEB<br />

TLEB<br />

N<br />

> 170 mm<br />

S<br />

BALOGH SA, 189 rue d'Aubervilliers CP97 75886 PARIS Cedex 18 FRANCE Tél : 33 (0)1 44 65 65 00 Fax : 33 (0)1 44 65 65 10<br />

S.A à Directoire au Capital de 800 000 Euros - R.C.B. PARIS 582 061 073<br />

subject to modifications Ref: F-02-49-04-GB TLE B891/PUR