R/W head<br />
189, rue d'Aubervilliers CP 97 75886 PARIS Cedex18 France<br />
33 (0)1.44.65.65.00 http://www.balogh-rfid.com<br />
33 (0)1.44.65.65.10 contact@balogh-rfid.com<br />
IDENTIFICATION SYSTEMS<br />
<strong>TCF</strong> <strong>100</strong><br />
GENERAL FEATURES ——————————–———————–——–—————————————————-———————–———–—<br />
<strong>TCF</strong> <strong>100</strong> is an R/W head allowing to exchange data with tags TAF without contact,<br />
using a protocol compliant with the standards ISO 18000-3 mode 1 and ISO 15693.<br />
It has to be linked up to a <strong>Balogh</strong> interface, chosen among:<br />
• fieldbus interfaces BI ... FcFc (slave),<br />
• MELS 30 Fc (slave),<br />
• CEPR96 Fc (programmable) and CFER 24Fc,<br />
• MRER 21Fc# or #Fc (station of the Modul .R identification network).<br />
ASSEMBLY DATA ——————————–——–——-——————————–—-———————————————————————————<br />
Assembly using two screws (length under head ≥ 35 mm, right-angled distances: 104 x 65 mm):<br />
transmission zone centre<br />
Connection:<br />
The <strong>TCF</strong> <strong>100</strong> is fitted with a 5-pin M12 metallic male socket.<br />
Use a corresponding female cable connector (A-coded, ref. 202 274) and a shielded cable with the following characteristics:<br />
• max. length: 50 m,<br />
• overall max. capacity between conductors and shield: 10 nF.<br />
The shield must be in contact to the cable connector housing by a 360° round crimping.<br />
For various possible interfaces, <strong>Balogh</strong> proposes cables with straight connector(s):<br />
• PUR cordset 3+ de 5 m 2) (ref. 495XXB4512) for BI.. interfaces<br />
(refer to the Accessories corresponding data sheet),<br />
• PUR cable FFMD5/12 (length: 2, 10 or 15 m) for the other interfaces<br />
(refer to the table opposite for wire colours).<br />
The coding peg at 10:30 allows you to plug some right-angled<br />
cable connectors (check to make sure that yours are OK):<br />
1) red in the first models FFMD5/12<br />
2)<br />
10 and 25 m on request<br />
Pin nr Description Wire colour<br />
1 +24VDC brown 1)<br />
2 Output white<br />
3 Input blue<br />
4 0 V black<br />
5 0 V green/yellow
C<br />
H<br />
A<br />
R<br />
A<br />
C<br />
T<br />
E<br />
Functional<br />
TAF 50 TAF 93<br />
direction of travel: longitudinal transversal longitudinal transversal<br />
tag back: isolated isolated against steel isolated against steel<br />
Parameters<br />
Min. Typ. Min. Typ. Min. Typ. Min. Typ. Min. Typ. Min. Typ. unit<br />
S n<br />
"nominal" range 15 <strong>100</strong> 15 <strong>100</strong> 25 140 15 65 25 140 15 65 mm<br />
S r<br />
recommended range 0.5 x S n<br />
mm<br />
LS r<br />
length of transmiss. zone @Sr 110 1) 95 2) 135 3) 85 4) 110 5) 60 6) mm<br />
D er<br />
distance betw. <strong>TCF</strong> end-to-end 330 290 410 310 370 240 mm<br />
D tt<br />
distance betw. TAF end-to-end 330 290 410 310 370 240 mm<br />
Test conditions:<br />
• Tag parallel to the head (tag tilt < 10°).<br />
• No metal round the tag and round the head either.<br />
• Maximum authorised offsets for LSr to reach<br />
at least the published value:<br />
R<br />
I<br />
S<br />
T<br />
I<br />
C<br />
S<br />
General Electron. Power<br />
- angular: 20° (for 3) to 6) )<br />
- lateral :<br />
1) ± 15 mm<br />
2) ± 20 mm<br />
MIN NOM MAX unit<br />
Supply direct voltage (ripple included) 21 24 29 V<br />
Protection against polarity reversal yes -<br />
Supply current @24VDC 90 mA<br />
Protection against short-circuits<br />
yes<br />
Carrier frequency 13.56 MHz<br />
Ambient temperature - 25 + 70 °C<br />
Protection rating IP 65 -<br />
Casing PA 12 (GF30%) -<br />
Weight 550 g<br />
3)<br />
± 20 mm<br />
4)<br />
± 8 mm<br />
5)<br />
± 25 mm<br />
6)<br />
± 10 mm.<br />
A<br />
S<br />
S<br />
E<br />
M<br />
B<br />
L<br />
Y<br />
The head is not to be mounted directly in a recessed metal cavity;<br />
a minimum metal-free clearance is required round the head:<br />
b<br />
R<br />
E<br />
C<br />
O<br />
M<br />
M<br />
E<br />
N<br />
D<br />
A<br />
T<br />
I<br />
O<br />
N<br />
S<br />
a ≥ 30 mm<br />
b ≥ 30 mm<br />
To avoid interference between two <strong>TCF</strong> <strong>100</strong>, there must be a minimum space (D er ) between them<br />
(refer to the above table).<br />
a<br />
BALOGH SA, 189 rue d'Aubervilliers CP97 75886 PARIS Cedex 18 FRANCE 33 (0)1 44 65 65 00 33 (0)1 44 65 65 10<br />
S.A à Directoire au Capital de 800 000 € - R.C.B. PARIS 582 061 073.<br />
Subject to modification.<br />
Ref: F-<strong>TCF</strong> <strong>100</strong>-1.2 - EN