Data sheet MOF100 - Balogh technical center
Data sheet MOF100 - Balogh technical center Data sheet MOF100 - Balogh technical center
R/W Mono-Block 189, rue d'Aubervilliers CP 97 75886 PARIS Cedex18 France 33 (0)1.44.65.65.00 http://www.balogh-rfid.com 33 (0)1.44.65.65.10 balogh.sales@balogh-rfid.com IDENTIFICATION SYSTEMS MOF 100 GENERAL FEATURES ——————————–———————–——–—————————————————-———————–———–— MOF 100 is an R/W Mono-Block allowing to exchange data with tags TAF without contact, using a protocol compliant with the standards ISO 18000-3 mode 1 & ISO 15693, Philips SLI2 ®, Texas Instrument Tagit ® ... (other chips on demand) It provides an RS-232 interface using an M12 male socket. A PC with the "MO# config" utility (downloadable from the website www.baloghrfid.com, lounge: Clients/documentation ) is required to configure the COM link. In addition the PC can access the data in the tags using an easy-to-use specialty Point-to-Point Protocol. Conversion from RS-232 to RS-485 using a CLS 110C4 converter. For other conversions please contact us. The node number is also configured with the PC. Available messaging instructions: Modbus ® / Jbus ® . MOF 100 DEMO KIT (order with the ref. 239XXB2880) —–—————–———–-—————–————————--——————— • One MOF 100, three TAF 50 tags (dimensions Ø50x1.6x3.2), • One cord intended for communication and 230 VAC supply, • "MO# demo" software for PC running under Windows 95, 98, 2000, NT, and XP (downloadable from the website www.balogh-rfid.com, lounge: Clients/documentation ). ASSEMBLY DATA ——————————–——–——-——————————–—-——————————————————————————— Assembly using two screws (length under head ≥ 35 mm, right-angled distances: 104x65 mm): transmission zone centre Connection: The MOF 100 is fitted with a 5-pin M12 metallic male socket. Use a corresponding female cable connector (A-coded, ref. 202 274). The coding peg at 10:30 allows you to plug some right-angled cable connectors (check to make sure that yours are OK): MODBUS is a registered trademark of Modicon, JBUS of April. Pin nr Description 1 +Vcc 2 Tx RS-232 3 Rx RS-232 4 & 5 0 V
R/W Mono-Block<br />
189, rue d'Aubervilliers CP 97 75886 PARIS Cedex18 France<br />
33 (0)1.44.65.65.00 http://www.balogh-rfid.com<br />
33 (0)1.44.65.65.10 balogh.sales@balogh-rfid.com<br />
IDENTIFICATION SYSTEMS<br />
MOF 100<br />
GENERAL FEATURES ——————————–———————–——–—————————————————-———————–———–—<br />
MOF 100 is an R/W Mono-Block allowing to exchange data with tags TAF without contact,<br />
using a protocol compliant with the standards ISO 18000-3 mode 1 & ISO 15693,<br />
Philips SLI2 ®, Texas Instrument Tagit ® ... (other chips on demand)<br />
It provides an RS-232 interface using an M12 male socket.<br />
A PC with the "MO# config" utility (downloadable from the website www.baloghrfid.com,<br />
lounge: Clients/documentation ) is required to configure the COM link.<br />
In addition the PC can access the data in the tags using an easy-to-use specialty<br />
Point-to-Point Protocol.<br />
Conversion from RS-232 to RS-485 using a CLS 110C4 converter.<br />
For other conversions please contact us.<br />
The node number is also configured with the PC.<br />
Available messaging instructions: Modbus ® / Jbus ® .<br />
MOF 100 DEMO KIT (order with the ref. 239XXB2880) —–—————–———–-—————–————————--———————<br />
• One MOF 100, three TAF 50 tags (dimensions Ø50x1.6x3.2),<br />
• One cord intended for communication and 230 VAC supply,<br />
• "MO# demo" software for PC running under Windows 95, 98, 2000, NT, and XP (downloadable from the website<br />
www.balogh-rfid.com, lounge: Clients/documentation ).<br />
ASSEMBLY DATA ——————————–——–——-——————————–—-———————————————————————————<br />
Assembly using two screws<br />
(length under head ≥ 35 mm,<br />
right-angled distances: 104x65 mm):<br />
transmission<br />
zone centre<br />
Connection:<br />
The MOF 100 is fitted with a 5-pin M12 metallic male socket.<br />
Use a corresponding female cable connector (A-coded, ref. 202 274).<br />
The coding peg at 10:30 allows you to plug some right-angled<br />
cable connectors (check to make sure that yours are OK):<br />
MODBUS is a registered trademark of Modicon, JBUS of April.<br />
Pin nr Description<br />
1 +Vcc<br />
2 Tx RS-232<br />
3 Rx RS-232<br />
4 & 5 0 V
C<br />
H<br />
A<br />
R<br />
A<br />
Functional<br />
TAF 50 TAF 93<br />
direction of travel: longitudinal transversal longitudinal transversal<br />
tag back: isolated isolated against steel isolated against steel<br />
Parameters<br />
Min. Typ. Min. Typ. Min. Typ. Min. Typ. Min. Typ. Min. Typ. unit<br />
S n<br />
"nominal" range 15 100 15 100 25 140 15 65 25 140 15 65 mm<br />
S r<br />
recommended range 0.5 x S n<br />
mm<br />
LS r<br />
length of transmiss. zone @Sr 110 1) 95 2) 135 3) 85 4) 110 5) 60 6) mm<br />
D er<br />
distance betw. TCF end-to-end 330 290 410 310 370 240 mm<br />
D tt<br />
distance betw. TAF end-to-end 330 290 410 310 370 240 mm<br />
C<br />
T<br />
E<br />
R<br />
I<br />
S<br />
T<br />
I<br />
C<br />
S<br />
A<br />
S<br />
S<br />
E<br />
M<br />
B<br />
L<br />
Y<br />
R<br />
E<br />
C<br />
O<br />
M<br />
M<br />
E<br />
N<br />
D<br />
A<br />
T<br />
I<br />
O<br />
N<br />
S<br />
General Electron. Power<br />
data buffer capacity 80 byte<br />
Test conditions:<br />
• Tag parallel to the head (tag tilt < 10°).<br />
• No metal round the tag and round the head either.<br />
• Maximum authorised offsets for LSr to reach<br />
at least the published value:<br />
- angular: 20° (for 3) to 6) )<br />
- lateral :<br />
a ≥ 30 mm<br />
b ≥ 30 mm<br />
BALOGH SA, 189 rue d'Aubervilliers CP97 75886 PARIS Cedex 18 FRANCE 33 (0)1 44 65 65 00 33 (0)1 44 65 65 10<br />
S.A à Directoire au Capital de 800 000 € - R.C.B. PARIS 582 061 073.<br />
b<br />
MIN NOM MAX unit<br />
Supply direct voltage (ripple included) 21 24 29 V<br />
Protection against polarity reversal yes -<br />
Supply current @24VDC 90 mA<br />
Protection against short-circuits<br />
1) ± 15 mm<br />
2) ± 20 mm<br />
Carrier frequency 13.56 MHz<br />
Ambient temperature - 25 + 70 °C<br />
Protection rating IP 65 -<br />
Casing PA 12 (GF30%) -<br />
Weight 550 g<br />
3)<br />
± 20 mm<br />
a<br />
4)<br />
± 8 mm<br />
yes<br />
Subject to modification.<br />
5)<br />
± 25 mm<br />
The head is not to be mounted directly in a recessed metal cavity;<br />
a minimum metal-free clearance is required round the head:<br />
6)<br />
± 10 mm.<br />
To avoid interference between two MOF 100, there must be a minimum space (D er ) between them<br />
(refer to the above table).<br />
Ref: F-MOF 100-1.3-EN