24.03.2015 Views

Swimming Pool Inspection Report - Julie Wyss

Swimming Pool Inspection Report - Julie Wyss

Swimming Pool Inspection Report - Julie Wyss

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Swimming</strong> <strong>Pool</strong> <strong>Inspection</strong> <strong>Report</strong><br />

Clean Sweep <strong>Pool</strong> Service<br />

P.O. Box 342<br />

For 123 Main St. Greattown, DE 12345<br />

Item<br />

Saratoga, Ca. 95071<br />

(831)<br />

Description<br />

336-3296<br />

Value<br />

Stereo<br />

Property<br />

system<br />

Address: 7112 Earlswood Ct.<br />

Model<br />

San Jose<br />

KK12,<br />

Ca.<br />

serial #000-000 2,900<br />

Real Estate Rep. Steve Trotter / Intero Realty<br />

Video Escrow recorder No.<br />

Screen model, serial #000-000 450<br />

Date: 3/26/10<br />

Camcorder Beauty View 56, serial #000-000 875<br />

<strong>Pool</strong> Builder<br />

Shape<br />

Item: Result of <strong>Inspection</strong>: Approx. Cost to Repair<br />

or Replace:<br />

UNKNOWN<br />

FREE FORM<br />

Size APPROX. 16’ X 36’<br />

Volume<br />

Coping<br />

Tile<br />

<strong>Pool</strong> Decking<br />

Plaster<br />

Visible Structural Cracks<br />

Ladder/Handrails<br />

Diving Board/Slide<br />

Water Chemistry<br />

<strong>Pool</strong> Pump<br />

Booster Pump<br />

Seal Leak/Bearing Noise<br />

APPROX. 15,000 GAL.<br />

CANTILEVERED BRICK STYLE<br />

STANDARD BLUE<br />

CONCRETE AGGREGATE<br />

WHITE<br />

NONE NOTICED<br />

NONE<br />

NONE<br />

O.K.<br />

STA RITE MG .75 HP<br />

POLARIS PB-4 .75 HP<br />

NONE NOTICED<br />

Auto. Cleaner POLARIS 380 ***SEE SUMMARY<br />

Filter: Type/Size<br />

Plumbing<br />

P/T FNS 36 SF D.E.<br />

PVC / COPPER<br />

<strong>Pool</strong> Light FLOODED ***SEE SUMMARY<br />

Time Clocks<br />

INTERMATIC<br />

Page: 1 of 1 Date: 1/1/95 Page total: 4,225


<strong>Inspection</strong>: page 2<br />

Item: Result of <strong>Inspection</strong>: Approx. Cost to Repair<br />

or Replace:<br />

Heater TELEDYNE LAARS EPS-250K ***SEE SUMMARY<br />

Valves<br />

N/A<br />

Misc. SOLAR CONTROL BOX ***SEE SUMMARY<br />

SUMMARY:<br />

The <strong>Swimming</strong> <strong>Pool</strong> appeared in good condition. Related Equipment was functioning properly. Areas of note are listed<br />

below in order of the inspection:<br />

1) Auto Cleaner: The Back-Up Valve for the unit was missing. Suggest replacing to keep the Cleaner from hanging up.<br />

Cost $60.<br />

2) <strong>Pool</strong> Light : The <strong>Pool</strong> Light worked, however the Light Canister is partially flooded. Suggest a Bulb & Gasket<br />

replacement before Light becomes compromised with corrosion.<br />

Cost $145.<br />

3) Heater: The Heater did not fire. The Pilot Assembly is likely obstructed.<br />

Cost to repair $95+ depending on findings.<br />

4) Misc: The Electrical Package for an abandoned Solar Control is still connected to the Pump Timer.<br />

Suggest removing for safety.<br />

Cost nominal.<br />

***Suggest checking with Current Owner regarding water loss. Evaporation rates of 1”-2” per week (Summer) are<br />

considered “normal”. Greater loss than this may indicate a more serious leak situation.<br />

* Conditions are that which exist at the time of inspection and are by no means a guarantee of future performance.<br />

<strong>Inspection</strong> process is primarily visual and therefore may not reveal hidden structural or internal problems.<br />

Page: 1 of 1 Date: 1/1/95 Page total: 4,225