Maintenance Figure 3-4: Particle Filter Assembly Tank Particle Filter 1. Turn the unit off. A – O-ring B – Filter C – Screen Fitting 2. Close the blue recovery tank valve. 3. Remove the blue hose from the filter. 4. Remove the filter from the tank valve. 5. Carefully remove the O-ring and the screen element from the brass housing. 6. Wash the screen element with mild soap and water and blow dry with compressed air. 7. Reassemble the filter taking care not to damage the screen or O-ring. Lubricate the O-rings with refrigerant oil. Order replacement parts by mail or call your Equiserv Service Representative at 1-800-225-5786. 8. Install the filter onto the tank valve. 9. Attach the hose to the filter. 10. Open the tank valve and check for leaks. Prolonged Storage of Kool Kare Follow this procedure before storing your Kool Kare unit for prolonged periods. 1. Service the oil separator using Maintaining the Oil Separator Bowl procedure in this chapter. 2. Change the compressor oil using Maintaining the Compressor procedure in this chapter. 3. Close both hand valves on the recovery tank. 3-10
Maintenance Troubleshooting Symptom Possible Cause Remedy Machine does not turn on • Power cord not plugged in – Plug in cord • No power in AC outlet • Circuit breaker on machine tripped – Check power source – Reset 15 amp circuit breaker by turning power switch off, then on Refrigerant not being • Panel hand valves not open – Open panel hand valves removed from vehicle • Service couplers not open – Open service couplers Excessive purging of • Fitting(s) not properly – Tighten fitting(s) finger tight non-condensable gasses connected to master filter • Leaky service hose or adapter connection drawing in air • Loose oil separator bowl, or damaged/missing bowl gasket – Tighten fittings or replace seals in finger tight fittings – Replace bowl gasket and/or tighten bowl hand tight Does not charge • Blue hand valve on recovery – Open blue hand valve tank not open • Fitting not properly connected to recovery tank • Panel hand valves not open • No refrigerant in tank • Clogged particle filter – Tighten fitting finger tight – Open panel hand valves – Fill tank with refrigerant – Clean filter Machine does not draw • Loose hose connection – Tighten loose hose a vacuum connections • Oil separator gasket cut or missing – Replace oil separator gasket 3-11
- Page 6 and 7: Safety Information The signal word
- Page 8 and 9: Safety Information Oil (Lubricant)
- Page 10 and 11: Safety Information Risk of injury.
- Page 12 and 13: ii Table of Contents
- Page 14 and 15: Trademark and Copyright Information
- Page 16 and 17: Using This Manual Safety Messages S
- Page 18 and 19: viii Using This Manual
- Page 20 and 21: Introduction Refrigerant Gases Halo
- Page 22 and 23: Introduction Refrigerant Substitute
- Page 24 and 25: Introduction Functional Description
- Page 26 and 27: Introduction Back View Figure 1-2:
- Page 28 and 29: Introduction Particle Filter Assemb
- Page 30 and 31: Introduction Language Selection Wit
- Page 32 and 33: 1-14 Introduction
- Page 34 and 35: Installation and Operation 3. Conne
- Page 36 and 37: Installation and Operation Adding R
- Page 38 and 39: Installation and Operation Operatio
- Page 40 and 41: Installation and Operation Connecti
- Page 42 and 43: Installation and Operation — If t
- Page 44 and 45: Installation and Operation Charge O
- Page 46 and 47: Installation and Operation Removing
- Page 48 and 49: Maintenance Maintaining the Oil Sep
- Page 50 and 51: Maintenance Master Filter The maste
- Page 52 and 53: Maintenance Changing the Master Fil
- Page 54 and 55: Maintenance • Wear safety goggles
- Page 58 and 59: Maintenance Symptom Possible Cause
- Page 60: 3-14 Maintenance
Maintenance<br />
Figure 3-4: Particle Filter Assembly<br />
Tank Particle Filter<br />
1. Turn the unit off.<br />
A – O-ring<br />
B – Filter<br />
C – Screen Fitting<br />
2. Close the blue recovery tank valve.<br />
3. Remove the blue hose from the filter.<br />
4. Remove the filter from the tank valve.<br />
5. Carefully remove the O-ring and the screen element from<br />
the brass housing.<br />
6. Wash the screen element with mild soap and water and<br />
blow dry with compressed air.<br />
7. Reassemble the filter taking care not to damage the<br />
screen or O-ring. Lubricate the O-rings with refrigerant<br />
oil. Order replacement parts by mail or call your<br />
Equiserv Service Representative at 1-800-225-5786.<br />
8. Install the filter <strong>on</strong>to the tank valve.<br />
9. Attach the hose to the filter.<br />
10. Open the tank valve and check for leaks.<br />
Prol<strong>on</strong>ged Storage of Kool Kare<br />
Follow this procedure before storing your Kool Kare unit for<br />
prol<strong>on</strong>ged periods.<br />
1. Service the oil separator using Maintaining the Oil<br />
Separator Bowl procedure in this chapter.<br />
2. Change the compressor oil using Maintaining the<br />
Compressor procedure in this chapter.<br />
3. Close both hand valves <strong>on</strong> the recovery tank.<br />
3-10