Installation and Operation Adding Refrigerant to Kool Kare 18. Connect short red and blue hoses (not hoses marked high and low) in rear of cabinet to respective ports on recovery tank. A particle filter is installed on the liquid port (nearest blue hand valve). 19. Turn both valves on recovery tank counter-clockwise until completely open. 20. Rotate tank so hoses are slack and do not interfere with scale movement. 21. Secure tank using hook and loop strap. Be sure strap is not twisted and temperature probe is against the side of the recovery tank. The recovery tank must contain enough refrigerant to charge the vehicle. Before complete charging operation can occur, the tank must contain enough refrigerant for the charge desired plus 3 pounds. For example, to charge 2 pounds t
Installation and Operation 9. Select CONTINUE. The following messages display: WAITING FOR STABLE SCALE! RECYCLING REFRIGERANT FROM VEHICLE! — The refrigerant continues to recycle until the virgin tank valve is closed, or the virgin tank is empty. — If t
- Page 1: USER’S MANUAL Kool Kare
- Page 4 and 5: Part Number ZEEAC304D Revision A ©
- Page 6 and 7: Safety Information The signal word
- Page 8 and 9: Safety Information Oil (Lubricant)
- Page 10 and 11: Safety Information Risk of injury.
- Page 12 and 13: ii Table of Contents
- Page 14 and 15: Trademark and Copyright Information
- Page 16 and 17: Using This Manual Safety Messages S
- Page 18 and 19: viii Using This Manual
- Page 20 and 21: Introduction Refrigerant Gases Halo
- Page 22 and 23: Introduction Refrigerant Substitute
- Page 24 and 25: Introduction Functional Description
- Page 26 and 27: Introduction Back View Figure 1-2:
- Page 28 and 29: Introduction Particle Filter Assemb
- Page 30 and 31: Introduction Language Selection Wit
- Page 32 and 33: 1-14 Introduction
- Page 34 and 35: Installation and Operation 3. Conne
- Page 38 and 39: Installation and Operation Operatio
- Page 40 and 41: Installation and Operation Connecti
- Page 42 and 43: Installation and Operation — If t
- Page 44 and 45: Installation and Operation Charge O
- Page 46 and 47: Installation and Operation Removing
- Page 48 and 49: Maintenance Maintaining the Oil Sep
- Page 50 and 51: Maintenance Master Filter The maste
- Page 52 and 53: Maintenance Changing the Master Fil
- Page 54 and 55: Maintenance • Wear safety goggles
- Page 56 and 57: Maintenance Figure 3-4: Particle Fi
- Page 58 and 59: Maintenance Symptom Possible Cause
- Page 60: 3-14 Maintenance
Installati<strong>on</strong> and Operati<strong>on</strong><br />
Adding Refrigerant to Kool Kare<br />
18. C<strong>on</strong>nect short red and blue hoses (not hoses marked<br />
high and low) in rear of cabinet to respective ports <strong>on</strong><br />
recovery tank. A particle filter is installed <strong>on</strong> the liquid<br />
port (nearest blue hand valve).<br />
19. Turn both valves <strong>on</strong> recovery tank counter-clockwise until<br />
completely open.<br />
20. Rotate tank so hoses are slack and do not interfere with<br />
scale movement.<br />
21. Secure tank using hook and loop strap. Be sure strap is<br />
not twisted and temperature probe is against the side of<br />
the recovery tank.<br />
The recovery tank must c<strong>on</strong>tain enough refrigerant to charge<br />
the vehicle. Before complete charging operati<strong>on</strong> can occur, the<br />
tank must c<strong>on</strong>tain enough refrigerant for the charge desired plus<br />
3 pounds. For example, to charge 2 pounds t<str<strong>on</strong>g>here</str<strong>on</strong>g> must be at<br />
least 5 pounds in the tank. If t<str<strong>on</strong>g>here</str<strong>on</strong>g> is not enough refrigerant in<br />
the tank the charge operati<strong>on</strong> does not functi<strong>on</strong>. Depending<br />
up<strong>on</strong> these requirements, the recovery tank may be filled with<br />
as much or as little refrigerant as desired.<br />
1. Attach adapter (part number: 1-15080) to the virgin tank.<br />
2. Attach blue (low) service hose coupler to adapter.<br />
3. Open valve <strong>on</strong> the virgin tank. Open blue (low) service<br />
coupler and c<strong>on</strong>trol panel valve. Keep the virgin tank in<br />
an upright positi<strong>on</strong>.<br />
4. Plug the power cord into a properly grounded supply line.<br />
Refer to the ID plate <strong>on</strong> the back of your Kool Kare unit<br />
for proper supply voltage.<br />
5. Turn <strong>on</strong> the power switch. Four screens display in the<br />
following order:<br />
— The Kool Kare Welcome screen,<br />
— The Software Versi<strong>on</strong> screen,<br />
— The Adjust C<strong>on</strong>trast screen–Adjust or Skip, and<br />
— The Recycle screen.<br />
6. Select YES. The Vacuum screen displays.<br />
7. Select NO. The Charging screen displays.<br />
8. Select NO. The C<strong>on</strong>necti<strong>on</strong> Check screen displays.<br />