Mounting Details - <strong>MTR</strong>QL<br />

Minimum clearance required<br />

(for maintenance or future upgrades)<br />

*consult factory for alternative recommendations<br />

if access above fixture is not available<br />

4’ head = 60” (1524mm)<br />

3’ head = 48” (1219mm)<br />

2’ head = 36” (914mm)<br />

8" (200mm) <strong>Square</strong><br />

(Typical All Heights)<br />

Height (12’ Nominal Shown) = See Chart Below for All Heights<br />

Pole Height is Nominal 3’- 8 3 /16" (1123mm)<br />

3 1 /2" (89mm)<br />

(4’ Lit Section)<br />

(Typical All Heights)<br />

3 1 /2" (89mm)<br />

(Typical All Heights)<br />

8" (200mm) <strong>Square</strong><br />

(Typical All Heights)<br />

4" x 9 5 /8" (102mm x 245mm)<br />

Handhole provided with fl<strong>us</strong>h cover<br />

and stainless steel tamper-resistant<br />

hardware (typical all heights).<br />

Height (12’ Nominal Shown) = See Chart Below for All Heights<br />

2’- 9 7 /8" (861mm)<br />

(3’ Lit Section)<br />

Pole Height is Nominal<br />

Height (12’ Nominal Shown) = See Chart Below for All Heights<br />

1’- 11 1 /16"<br />

(585mm)<br />

(2’ Lit Section)<br />

Pole Height is Nominal<br />

Overall Height<br />

Nominal (Actual)<br />

Lit Section<br />

Nominal (Actual)<br />

Pole Height<br />

Nominal (Actual)<br />

ASSHTO 1994<br />

Max EPA Wind Rating<br />

ASSHTO 2001<br />

Max EPA Wind Rating<br />

ASSHTO 2009<br />

Max EPA Wind Rating<br />

10’ (10’) 4’ (3’ - 8 3 /16”) 6’ (6’ - 3 13 /16”) 200mph 200mph 200mph<br />

10’ (10’) 3’ (2’ - 9 7 /8”) 7’ (7’ - 2 1 /8”) 200mph 200mph 200mph<br />

10’ (10’ - 2 13 /16”) 2’ (1’ - 11 1 /16”) 8’ (8’ - 3 13 /16”) 200mph 200mph 200mph<br />

12’ (12’) 4’ (3’ - 8 3 /16”) 8’ (8’ - 3 13 /16”) 200mph 200mph 200mph<br />

12’ (12’) 3’ (2’ - 9 7 /8”) 9’ (9’ - 2 1 /8”) 200mph 200mph 200mph<br />

12’ (12’ - 2 13 /16”) 2’ (1’ - 11 1 /16”) 10’ (10’ - 3 13 /16”) 200mph 200mph 200mph<br />

14’ (14’) 4’ (3’ - 8 3 /16”) 10’ (10’ - 3 13 /16”) 200mph 200mph 200mph<br />

14’ (14’) 3’ (2’ - 9 7 /8”) 11’ (11’ - 2 1 /8”) 200mph 200mph 200mph<br />

14’ (14’ - 2 13 /16”) 2’ (1’ - 11 1 /16”) 12’ (12’ - 3 13 /16”) 200mph 200mph 200mph<br />

16’ (16’) 4’ (3’ - 8 3 /16”) 12’ (12’ - 3 13 /16”) 190mph 190mph 190mph<br />

16’ (16’) 3’ (2’ - 9 7 /8”) 13’ (13’ - 2 1 /8”) 190mph 190mph 190mph<br />

16’ (16’) 2’ (1’ - 11 1 /16”) 14’ (14’ - 0 15 /16”) 190mph 190mph 190mph<br />

Selux Corp. © 2013<br />

<strong>MTR</strong>QL-0713-03 (ss-v1.2 )<br />

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in ouropinion will not alter<br />

the function of the product. Specification sheets found at www.<strong>selux</strong>.<strong>us</strong> are the most recent versions and supercede all other printed or electronic versions.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!