<strong>SE</strong>TTING THE MIDI CHANNEL (GLOBAL “MIDI CH”)<br />
In order to exchange data with an external MIDI device, <strong>ToneLab</strong><strong>SE</strong>’s MIDI channel<br />
must match the MIDI channel of your external MIDI device. Here’s how to set<br />
the MIDI channel.<br />
1. Press the GLOBAL button (3.4).<br />
2. The name display (3.8) will show “MIDI CH.” If a different parameter is<br />
selected, press the √, ® buttons (3.2) to change the display.<br />
3. Use the value knob 3 (2.2) or the ▲, ▼ buttons (3.1) to set <strong>ToneLab</strong><strong>SE</strong>’s MIDI<br />
channel.<br />
4. Set the MIDI channel of your connected external MIDI device.<br />
For details on how to set the MIDI channel of your external MIDI device, refer<br />
to its owner’s <strong>manual</strong>.<br />
PROGRAM CHANGE (GLOBAL “PCHG OUT”)<br />
When you switch programs on <strong>ToneLab</strong><strong>SE</strong>, a program change message is transmitted<br />
from the MIDI OUT jack, causing an external MIDI device to switch programs.<br />
Similarly, when <strong>ToneLab</strong><strong>SE</strong> receives a program change message, its<br />
program will switch automatically. Here’s how you can specify whether a program<br />
change message will be transmitted from the MIDI OUT jack when you switch programs<br />
on <strong>ToneLab</strong><strong>SE</strong>.<br />
NOTE: Program change numbers not used by <strong>ToneLab</strong><strong>SE</strong> will be ignored. For<br />
details on the range of program change numbers used by <strong>ToneLab</strong><strong>SE</strong>, refer to End<br />
of this <strong>manual</strong>.<br />
1. Press the GLOBAL button (3.4).<br />
2. Press the √, ® buttons (3.2) to make the name display (3.8) show “PCHG<br />
OUT.”<br />
3. Specify whether program change messages will be transmitted. Use value<br />
knob 6 (2.2) or the ▲, ▼ buttons (3.1) to make the desired setting.<br />
“OFF”: Program change messages will not be transmitted.<br />
“On”: Program change messages will be transmitted.<br />
CONTROL CHANGE (GLOBAL “CCHG I/O”)<br />
When you operate the EXPRESSION pedal 1, Expression pedal 2, or Control pedal of<br />
the <strong>ToneLab</strong><strong>SE</strong>, control change messages will be transmitted. This means that functions<br />
for the corresponding control change numbers on an external MIDI device can<br />
be controlled in realtime.<br />
Similarly, when <strong>ToneLab</strong><strong>SE</strong> receives control change messages from an external MIDI<br />
device, it will be controlled in the same way as if its own foot controller were operated.<br />
For a list of the functions that can be controlled from an external MIDI device, refer to<br />
step 4.<br />
Here you can specify whether <strong>ToneLab</strong><strong>SE</strong> will transmit and receive control change<br />
messages.<br />