Final report on link level and system level channel models - Winner
Final report on link level and system level channel models - Winner
Final report on link level and system level channel models - Winner
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
WINNER D5.4 v. 1.4<br />
Table 5.35: The 10, 50 <strong>and</strong> 90 % percentiles for the cumulative distributi<strong>on</strong> functi<strong>on</strong> of the delay<br />
proporti<strong>on</strong>ality factor in a rural envir<strong>on</strong>ment.<br />
Delay proporti<strong>on</strong>ality factor:<br />
Percentile<br />
r τ<br />
LOS<br />
NLOS<br />
10% 2.0 1.2<br />
50% 3.8 1.7<br />
90% 8.5 2.9<br />
mean 4.7 1.9<br />
5.4.10.5 Scenario D1<br />
The percentiles for the CDF of the delay proporti<strong>on</strong>ality factor for scenario D1 are presented in the Table<br />
5.36.<br />
Table 5.36: The 10, 50 <strong>and</strong> 90 % percentiles for the cumulative distributi<strong>on</strong> functi<strong>on</strong> of the delay<br />
proporti<strong>on</strong>ality factor in a rural envir<strong>on</strong>ment.<br />
delay proporti<strong>on</strong>al factor:<br />
Percentile<br />
r τ<br />
LOS NLOS<br />
10% 2.0 1.2<br />
50% 3.8 1.7<br />
90% 8.5 2.9<br />
mean 4.7 1.9<br />
5.4.11 Ricean K-factor<br />
Narowb<strong>and</strong> Ricean K factor in the LOS regi<strong>on</strong>s has been analysed. Ricean K-factor is the ratio of power<br />
of the direct LOS comp<strong>on</strong>ent to the total power of the diffused n<strong>on</strong>-line-of-sight comp<strong>on</strong>ents.<br />
5.4.11.1 Scenario A1<br />
The narrow-b<strong>and</strong> Ricean K-factor as a functi<strong>on</strong> of distance at 100 MHz b<strong>and</strong>width <strong>and</strong> 5.25 GHz centrefrequency<br />
in an indoor envir<strong>on</strong>ment is c<strong>on</strong>sidered in the corridor-corridor LOS propagati<strong>on</strong> c<strong>on</strong>diti<strong>on</strong>s.<br />
CDF of the K-factor is shown in the Figure 5.58. The fitting of the CDF with normal distributi<strong>on</strong> is<br />
shown.<br />
Figure 5.58: a) Distributi<strong>on</strong> of the K-factor in A1 indoor scenario at 5.25 GHz centre-frequency.<br />
K-factor in the A1 indoor scenario <strong>and</strong> LOS corridor to corridor propagati<strong>on</strong> c<strong>on</strong>diti<strong>on</strong>s at 5.25 GHz<br />
centre-frequency is shown in the figure Figure 5.59 as functi<strong>on</strong> of the BS – MS distance.<br />
Page 98 (167)