WINNER D5.4 v. 1.4<br />

13 65 -5.4 8.39 -59.0 -15.4<br />

14 75 -9.0 -27.5 14.1 -19.0<br />

15 85 -11.3 -43.9 -7.76 -21.3<br />

16 95 -12.5 13.7 -0.59 -22.5<br />

17 105 -13.6 63.8 -13.4 -23.6<br />

18 115 -15.1 2.31 3.29 -25.1<br />

19 125 -16.8 8.77 4.22 -26.8<br />

20 135 -18.7 31.1 15.9 -28.7<br />

3.2.2 Scenario B1<br />

The parameters of the CDL model have been extracted from measurements with chip frequency of 60<br />

MHz at frequency range of 5.3 GHz. The number of ZDSCs is selected to be close to the median <strong>and</strong><br />

provide low frequency correlati<strong>on</strong>. The CDL parameters of LOS <strong>and</strong> NLOS c<strong>on</strong>diti<strong>on</strong> are given in Table<br />

3.15 <strong>and</strong> Table 3.16, respectively.<br />

3.2.2.1 LOS<br />

Table 3.15: Scenario B1: LOS Clustered delay line model.<br />

ZDSC #<br />

delay<br />

[ns]<br />

Power<br />

[dB]<br />

AoD<br />

[º]<br />

AoA<br />

[º]<br />

K-<br />

factor<br />

[dB]<br />

MS speed = 50 km/h,<br />

directi<strong>on</strong> U(0 o ,360 o )<br />

1 0 0 0 0 16 -0.11 * -26.11 **<br />

2 10 -1.2 -22 -10 9 -1.72 -20.7<br />

3 25 -7.4 -12 20 3 -9.16 -22.16<br />

4 30 -7.4 -12 20 -17.4<br />

5 45 -8.4 -2 -123 -18.4<br />

6 65 -13.0 10 -31 -23<br />

7 85 -15.1 -4 161 -25.1<br />

8 105 -16.1 8 -7<br />

-26.1<br />

-∞<br />

Number of rays<br />

/ZDSC =10 +<br />

Ray Power [dB]<br />

ZDSC AS at MS [º] = =18<br />

ZDSC AS at BS [º] =3<br />

Composite AS at MS [º]<br />

=37.1<br />

Composite AS at BS [º] =<br />

5.6<br />

*<br />

**<br />

+<br />

Power of dominant ray,<br />

Power of each other ray<br />

Clusters with high K-factor will have 11 rays.<br />

3.2.2.2 NLOS<br />

ZDSC<br />

#<br />

delay<br />

[ns]<br />

Power<br />

[dB]<br />

Table 3.16: Scenario B1: NLOS Clustered delay line model.<br />

AoD<br />

[º]<br />

AoA<br />

[º]<br />

K-<br />

factor<br />

[dB]<br />

MS speed = 50 km/h,<br />

directi<strong>on</strong> U(0 o ,360 o )<br />

1 0 -1.25 4 0 9 -1.8 * -20.8 **<br />

2 10 0 40 25 6 -1 * -17 *<br />

3 40 -0.38 -10. 29 -10.38<br />

4 60 -0.10 48. -31 -10.10<br />

5 85 -0.73 -36. 37 -10.73<br />

6 110 -0.63 -40 21 -10.63<br />

7 135 -1.78 -26 13<br />

-∞<br />

Number of rays /ZDSC<br />

= 10 +<br />

Ray Power [dB]<br />

-11.78<br />

ZDSC AS at MS [º]<br />

=22<br />

ZDSC AS at BS [º]<br />

=10<br />

Composite AS at MS<br />

[º] =36.4<br />

Composite AS at BS<br />

[º] =12.4<br />

Page 31 (167)