Via LAN#1 the <strong>NavAid</strong> system is connected to the SCADA system, so that all important information can be<br />
retrieved via IEC 61850 or MODBUS TCP.<br />
LAN#2 is the service connector for update and diagnostics, so that service effort in terms of on-site operation<br />
can be kept as low as possible.<br />
The LightGuard Gateway communicates via TCP/IP with the control centre, receives control commands from<br />
the same and provides status information of the individual components.<br />
As required and depending on the <strong>NavAid</strong> controller type, one or two Light Control Modules are used for current<br />
consumption monitoring of the 5 nautical mile lanterns and spotlights and for spotlight brightness control.<br />
Components inside the cabinet<br />
1 LightGuard Gateway<br />
2 Network connectors<br />
LightGuard Gateway<br />
3 User interface with status indicators<br />
4 Surge protection<br />
5 LightGuard Bus modules<br />
(IM-01, LCM-01, depending on type,<br />
see table below)<br />
6 Terminal block<br />
7 Shield connection<br />
8 Cable glands<br />
9 Circuit breaker<br />
Type<br />
Components inside the cabinet<br />
LightGuard Gateway LightGuard Bus IM-01 LightGuard BUS LCM-01<br />
<strong>NavAid</strong> <strong>Controller</strong> Basic 1 0 0<br />
<strong>NavAid</strong> <strong>Controller</strong> Extended 1 1 1 1<br />
<strong>NavAid</strong> <strong>Controller</strong> Extended 2 1 1 2<br />
SABIK GmbH · Wilhelm-Maybach-Straße 3 · 19061 Schwerin · Germany<br />
Data Sheet <strong>NavAid</strong> <strong>Controller</strong> Version 1.01<br />
Fon +49 385 676700-0 · Fax +49 385 676700-99 · info@sabik.de 15/01/2013<br />
Page 2