PART 1 - GENERAL<br />

SECTION 01500<br />

CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS<br />

1.01 ACCESS TO SITE AND PARKING AREAS<br />

A. Contractor shall use the streets and areas assigned to him by the Owner for the purposes of access to the job<br />

site.<br />

B. Parking areas for cars of Contractor's employees shall be only as directed and/or allowed by the Owner.<br />

1.02 STAGING AREAS<br />

A. Contractor shall use only those areas assigned to him by the Owner for material storage, subcontractors’ sheds<br />

and staging areas.<br />

1.03 TEMPORARY SANITARY FACILITIES<br />

A. The Contractor shall furnish, install and maintain ample sanitary facilities for the use of his workmen and those<br />

of the subcontractors.<br />

B. Temporary toilets shall be installed at the time the Work is commenced and shall be maintained in compliance<br />

with all applicable health laws and regulations and the use of such facilities shall be enforced.<br />

C. Toilets shall be of the chemical type unless directed otherwise.<br />

D. Remove the temporary toilets and all traces thereof from the premises upon completion of the work.<br />

1.04 TEMPORARY UTILITIES<br />

A. The Contractor shall provide and pay for temporary water, gas, electricity and other services as may be<br />

required until premises are accepted by the Owner.<br />

B. The Contractor shall be responsible for the cost of the maintenance of these services and pay for all fuel and<br />

electricity consumed during the period of construction for whatever purpose it may be required.<br />

C. Permanent power costs shall also be borne by the Contractor until date of Substantial Completion as accepted<br />

by the Architect and Owner.<br />

1.05 TEMPORARY OFFICES AND SHEDS<br />

A. The Contractor shall provide, where directed by the Owner on the premises, such temporary offices and sheds<br />

as may be required for his Work and shall maintain same and remove from the premises when directed.<br />

1.06 TELEPHONE<br />

A. The Contractor shall provide, in his temporary offices, a straight line telephone with speaker phone capability<br />

for use of the Contractor from the commencement of operations until final acceptance. The Contractor shall<br />

pay all charges for telephone installation, service and removal.<br />

B. Provide one (1) facsimile machine at the field office building.<br />

1.07 COMPUTER COMMUNICATIONS<br />

A. The Contractor shall have the capability of sending and receiving e-mail in his temporary offices.<br />

1.08 TEMPORARY WIRING<br />

A. The Contractor shall provide all preliminary wiring necessary under this contract. The Contractor shall furnish<br />

and install a temporary wiring system adequate to furnish power and lighting for construction needed.<br />

B. Each subcontractor shall be responsible for extending service to their own temporary office.<br />

1.09 CONTRACTOR SAFETY<br />

A. The General Contractor shall at all times maintain a safe construction site which complies with all aspects of<br />

the OSHA Construction Safety Standard (29 CFR 1926).<br />

B. The General Contractor shall ensure that all subcontractors work safely and comply with the OSHA Standard.<br />

C. The General Contractor shall designate in writing a Site Safety Officer, and submit a written safety plan which<br />

details how safety will be managed throughout the project. A professional safety resource should also be<br />

identified for the project whether in-house or contract.<br />

D. Require the General Contractor to obtain written safety programs from subcontractors.<br />

E. The General Contractor should hold safety orientation meetings for each subcontractor. A review of safety<br />

issues should be a routine agenda item on weekly project meeting. The General Contractor should document<br />

all safety meetings and training sessions.<br />