Section 01410<br />

Page 2<br />

C. The laboratories are not authorized to revoke, alter, relax, enlarge or release any requirements of the Contract<br />

Documents, or to approve or accept any portion of the work. The duty of the laboratories is to test and/or<br />

sample and report on a timely basis.<br />

PART 2 - PRODUCTS<br />

2.01 MATERIALS<br />

A. Materials in conjunction with the work of this Section shall be as required for the various tests.<br />

PART 3 - EXECUTION<br />

3.01 SUBGRADE DENSITY TEST<br />

A. Establish moisture density relationship of subgrade and select fill in accordance with ASTM D-698.<br />

B. Perform in-place density test of completed select fill subgrade beneath building slabs-on-grade and stabilized<br />

sub-grade beneath paving in accordance with ASTM D-2167 as follows:<br />

1. Building Subgrade: one test per lift for each 5,000 s.f. area.<br />

3.02 TESTING OF CONCRETE<br />

A. Refer to Section 03300 for specific requirements. These apply to all concrete placed for Section 03300 and<br />

Section 02514.<br />

3.03 MORTAR, GROUT AND CONCRETE MASONRY UNITS<br />

A. Refer to Section 4100 and Section 4200 for specific requirements.<br />

3.04 STRUCTURAL STEEL<br />

A. Refer to Section 05100 for specific requirements.<br />

END OF SECTION<br />

NAPA CENTURY CENTER XD 12<br />