Section 09960<br />

Page 5<br />

H. Transparent (Clear) Finishes: Use multiple coats to produce glass smooth surface film of even luster.<br />

Provide a finish free of laps, cloudiness, color irregularity, runs, brush marks, orange peel, nail holes or other<br />

surface imperfections.<br />

I. Refinishing Wood Surfaces: Sand all existing clear finish wood surfaces. Fill all holes with stainable<br />

wood putty. Stain all blemishes to match existing color. Apply two (2) coats satin urethane finish.<br />

J. Refinishing Plaster and GWB Surfaces: Clean all surfaces per ASTM D 4258. Fill all holes and<br />

blemishes; sand, prime and paint per new finishes.<br />

3.05 CLEAN-UP AND PROTECTION<br />

A. Clean-Up: During progress of work, remove from site discarded paint materials, rubbish, cans and rags<br />

at end of each work day.<br />

1. Upon completion of painting work, clean window glass and other paint<br />

spattered surfaces. Remove spattered paint by proper methods of washing<br />

and scraping, using care not to scratch or otherwise damage finished<br />

surfaces.<br />

B. Protection: Protect work of other trades, whether to be painted or not, against damage by painting and<br />

finishing work. Correct any damage by cleaning, repairing or replacing, and repainting as acceptable to<br />

Architect.<br />

1. Provide “Wet Paint” signs as required to protect newly painted finishes.<br />

Remove temporary protective wrappings provided by others for protection<br />

of their work after completion of painting operations.<br />

2. At the completion of work of other trades, touch-up and restore all damaged<br />

or defaced painted surfaces.<br />

3.06 FINISH PAINTING SCHEDULE<br />

A. The following finish systems refer to products of Tnemec Company, Inc., unless indicated otherwise.<br />

NAPA CENTURY CENTER XD 12<br />

#165582<br />

1. EXTERIOR MASONRY, PREVIOUSLY UNCOATED-Block, Brick, Precast, Cast in Place,<br />

Concrete (Water repellency, graffiti protection)<br />

Coat 1: Tnemec/Chemprobe Series V626 Dur A Pell GS at 75 to 150 sq ft. per gal.<br />

Coat 2: Same as Coat 1<br />

2. New EXTERIOR MASONRY PRECAST AND CONCRETE-Block, Brick, Cast in Place<br />

Concrete<br />

Coat 1: Tnemec Series 156 Enviro-Crete at 8-10 mils DFT (Dry Film Thickness)<br />

Coat 2: Same as Coat 1<br />

3. EXTERIOR PLASTER,GLAZED BRICK,AND PREVIOUSLY PAINTED<br />

MASONRY<br />

Coat 1: Tnemec Series 151 Elasto-grip 3.04 - 4.0 mils DFT<br />

Coat 2: Tnemec Series 180 W. B. Tneme Crete at 5.0 to 7.0 mils DFT<br />

4. Existing Exterior Ferrous Metal<br />

Coat 1: Tnemec135 Chembuild at 3.0 to 5.0 mils DFT<br />

Coat 2: Tnemec 1028 Enduratone at 2.0 to 3.0 mils DFT<br />

5. New EXTERIOR FERROUS METAL<br />

(Surface Preparation: SSPC-SP#6) Coordinate w/sections 05120, 05500<br />

Coat 1: Tnemec Series 90-97 Tneme-Zinc (shop applied) at 3.0 mils DFT<br />

Coat 2: Tnemec Series N69/V69 Epoxoline at 3.0 mils DFT<br />

Coat 3: Tnemec Series 1080 Endura-Shield at 2.0 to 3.0 mils DFT<br />

6. EXTERIOR NON-FERROUS METAL<br />

(Surface Preparation: SSPC-SP#1) Followed by SSPC-SP3 or SP7