Section 09800<br />

Page 3<br />

2. Sherwin-Williams: ConFlex XL Smooth Elastomeric High Build Coating, A5-400 Series (optional).<br />

3. ConFlex XL Texture High Build Elastomeric Coating, A5-800 Series. Smooth texture is A5W800.<br />

A minimum total dry film thickness of 9.4-11.0 mils of topcoat recommended per coat.<br />

Performance Characteristics:<br />

Wind-Driven Rain Test ASTM D6904-03 Passes<br />

Water Vapor Permeance ASTM D1653 22 Perms<br />

Elongation ASTM D2370 300%<br />

Tensile Strength ASTM D2370 300 psi<br />

Freeze/Thaw Reistance ASTM D2243 Passes<br />

Low Temperature Flexibility ASTM D522-Method B Passes<br />

Mildew Resistant – containing agents which inhibit the growth of mildew on the sureface of the coating.<br />

D. Waterbased Catalyzed Epoxy: Sherwin-Williams Topcoat: Hi-Build Waterbased Catalyzed Epoxy,<br />

B71-100 Series. This product is a high performance, interior/exterior, VOC compliant, low odor, high<br />

film build, two-component, water based acrylic epoxy. It dries to a tough, tile-like finish that exhibits<br />

excellent durability and performance properties. It is resistant to moisture, abrasion, select chemicals,<br />

impact, and yellowing. Apply two coats 110-170 sq ft/gal per coat depending on substrate porosity and texture<br />

size. A minimum total dry film thickness of 4.0-6.0 mils per coat is required.<br />

Sherwin-Williams Primers for waterbased catalyzed epoxy: For tilt wall applications use Loxon Concrete<br />

Masonry Primer, A24W8300. For steel applications use Pro-Cryl Universal Metal Primer, B66-310 series. For<br />

Drywall Interior use ProMar 200 Int Latex Primer, B28W8200. For Drywall Exterior use Exterior Latex<br />

Wood Primer, B42W8041.<br />

E. VOC emissions: Provide low VOC products.<br />

1. Adhesives and sealants: Comply with California’s South Coast Air Quality Management District<br />

(SCAQMD) #1168 identified in Section 01352.<br />

2. Aerosol adhesives: Comply with Green Seal GS-36 identified in Section 01352<br />

3. Paints and coatings: Comply with SCAQMD #1113 identified in Section 01352<br />

PART 3 – EXECUTION<br />

3.01 EXAMINATION AND PREPARATION<br />

A. Allow 28-30 days after completion of panel erection &/or concrete mansory wall for curing of concrete &/or<br />

mortar.<br />

B. Examination:<br />

1. Examine substrate to which finely textured coating is to be applied. Do not proceed if unsatisfactory<br />

conditions exist which hamper proper application.<br />

C. Preparation:<br />

1. Surface to receive system shall be free of defects such as honeycombs, form marks, tie holes, concrete<br />

droppings, laitance, dirt, grease form release treatments, efflorescence, curing compounds, paint and other<br />

foreign materials.<br />

2. Remove all oil, dust, grease, dirt, loose rust, and other foreign material to ensure adequate adhesion, per<br />

manufactures recommendations. Form release agents, hardeners, etc. must be removed by sandblasting,<br />

shot-blasting, mechanical scarification , or suitable chemical means.<br />

3. Fill all cracks, voids, holes in excess of 3/8 inch and bugholes.<br />

D. Beginning of application means acceptance of substrate.<br />

G. Tolerances: Finish coat must be pinhole free.<br />

3.03 FIELD QUALITY CONTROL<br />

A. Maintain schedule of application of system in field office for owners/architect's review.<br />