Section 09510<br />

Page 3<br />

3.02 INSTALLATION<br />

A. Installation shall be by experienced craftsmen trained to do this type of work. Contractor shall use a laser device<br />

for installation of ceiling grid.<br />

B. Install acoustic treatment after moist materials have been installed. Maintain temperature of not less than 50° F<br />

in spaces having installation of acoustical materials.<br />

C. Perform installation according to the Code of Practices for Acoustical Ceiling System Installation as prepared by<br />

NACA, and Specifications for Acoustical Tile and Lay-in Panel Ceiling System as prepared by AMA.<br />

D. Install hanger wires not over 48" apart above the main beam, unless otherwise indicated or approved.<br />

E. Securely anchor hanger wires to structure above.<br />

F. Secure lower ends of hanger wires to main tees by three twists around itself. Space main tees 2'-0" on centers of<br />

2'x4' grid. Join cross tees to main tee with a positive interlock. At perimeter areas, columns, etc., secure angle<br />

molding to vertical surfaces. Rest tees on angle moldings at walls, columns, etc. Provide hanger wires at four<br />

corners of all light fixtures.<br />

G. Install main runner beams at 4'-0" on center in 2'x4' grid.<br />

H. Install cross tees perpendicular to the main runner beams on both sides of light fixtures and ceiling diffusers.<br />

I. Roll form angle moldings that must follow a curved wall, plane, radius or bend. Notching or cutting the exposed<br />

leg at angle molding to fit radius or bend will not be accepted.<br />

J. Install angle moldings at all points where ceiling abuts a dissimilar material.<br />

K. Unless indicated otherwise, lay out suspension system to the column center lines in areas where columns are free<br />

standing. Lay out system to center lines of rooms working in all four directions in areas that have no free<br />

standing columns. Cut units next to walls shall be more than 1/2 board width and/or length.<br />

L. Install acoustical treatment and suspension system according to instructions and recommendations of the<br />

manufacturer.<br />

M. Suspension system for ceilings shall be erected strong and rigid enough to carry the acoustical tile and support<br />

the light fixtures in a true and level plane.<br />

N. Erect suspension system level, straight, and parallel to walls.<br />

O. Cutting and splicing shall be done in a neat workmanlike manner.<br />

P. Expose no acoustic tile edges.<br />

Q. Cut holes in acoustic units as required for lighting fixtures, air conditioning outlets, sprinkler heads and speakers.<br />

Do not split into two pieces to accommodate fixtures.<br />

3.03 CLEANING AND PROTECTION<br />

A. Refer to Section 01710 - Cleaning.<br />

B. Upon completion of the work, remove damaged and soiled acoustical boards and replace with new matching<br />

material.<br />

C. Protect materials and accessories from damage.<br />

D. Remove excess materials, packaging, and debris from the job site.<br />

3.04 EXTRA STOCK<br />

A. Provide in accordance with Section 01750 - Spare Parts and Maintenance materials.<br />

B. Provide percent (6%) additional ceiling tile material, of each type, identical to that installed for maintenance and<br />

replacement use.<br />

END OF SECTION<br />