Section 09510<br />

Page 2<br />

C. Deliver materials with manufacturer's labels indicating brand name, pattern, size, thickness, and fire rating, as<br />

applicable, legible and intact.<br />

D. Store materials off the floor to assure proper protection from water and cover if necessary.<br />

E. Handle material so as to prevent soiling of finished acoustical units.<br />

PART 2 – PRODUCT<br />

2.01 SUSPENSION SYSTEM<br />

A. Product/Manufacturer: Prelude XL 15/16" exposed tee grid; Armstrong World Industries, Inc. Note: For areas<br />

requiring one-hour ceiling assembly, provide XL Fireguard grid and Fireguard-type acoustical tile.<br />

B. Components: All main beams and cross tees shall be commercial-quality hot dipped galvanized steel with<br />

minimum G30 coating as per ASTM A653. Exposed surfaces chemically cleansed, capping prefinished in<br />

baked polyester paint. Main beams and cross tees are double web steel construction with 15/16" type exposed<br />

flange design. Light gage steel cross tees shall have rotary stitching to improve column strength and staked-on<br />

end detail allowing easy cross tee removal and remounting.<br />

1. Structural Classification: Intermediate duty.<br />

2. Main Beam and Cross Tees shall be manufactured by Armstrong World Industries, Inc. Exposed bottom<br />

flange shall be continuous with unbroken roll-formed cap, made from steel, running the entire length of the<br />

member.<br />

a. Main Beam: Web height shall be 1½".<br />

b. Four Foot Cross Tee: Web height shall be minimum 1-3/8".<br />

c. Two Foot Cross Tee: Web height shall be minimum 1-3/8".<br />

3. Wall moldings shall be angle molding, Item #7800, manufactured by Armstrong World Industries, Inc., and<br />

have a nominal 7/8" exposed flange.<br />

4. Hanger wire shall be galvanized carbon steel per ASTM A641, soft temper, pre-stretched, with a yield stress<br />

load of at least 3 times design load, but not less than 12 gage (0.106") diameter.<br />

C. Color and finishes: All steel roll-formed parts, including cap, shall be chemically cleansed. Capping shall be<br />

prefinished in a baked polyester paint finish.<br />

1. Color shall be as described on the drawings and match the actual color of the selected ceiling tile, unless<br />

otherwise specified.<br />

2.02 ACOUSTICAL TILES - NO SUBSTITUTIONS.<br />

A. C1: Armstrong Fine Fissured, 2' x 2' – tegular edge, 5/8" thick, Cream (Item #1732CR).<br />

B. C2: Armstrong Fine Fissured, 2' x 2' – tegular edge, 5/8" thick, Cream (Item #1732CR).<br />

C. C3: Armstrong Fine Fissured with Humiguard Plus, 2' x 4', square edge, 5/8" thick, Black (Item #1729BL).<br />

D. C4: Armstrong Fine Fissured, 2' x 4' – square edge, 5/8" thick, White. (Item #1729WH).<br />

E. C5: Armstrong: Clean Room VL- Vinyl-Clad Gypsum Ceiling panel, Unperforated White, 2' x 4' square edge,<br />

5/8" thick (Item #871).<br />

F. C6: Armstrong Fine Fissured, 2' x 2' – square edge, 5/8" thick, Black. (Item #1728BL).<br />

G. C8: Armstrong: Clean Room VL - Vinyl-Clad Gypsum Ceiling panel, Unperforated White, 2' x 2' square edge,<br />

5/8" thick (Item #869).<br />

2.04 ACCESSORIES<br />

A. Hold Down Clips: Provide hold down clips at locations where 1 hour construction is required and elsewhere as<br />

noted on contract documents. Fire rated ceiling panels weighing one pound per square foot or more do not<br />

require hold down clips.<br />

B. Provide Armstrong Axiom Channel Profile, 8” face depth to form the cove in the Restrooms. Refer to Drawings<br />

for locations.<br />

2.05 CINEMARK STRATEGIC ACCOUNT PRICING<br />

A. Contact Armstrong’s Sherry Brunt at 1-800-442-4212 to secure details of the Armstrong-Cinemark Strategic<br />

pricing agreement.<br />

PART 3 - EXECUTION<br />

3.01 PREPARATION<br />

A. Examine spaces and correct defects that could interfere with proper installation.<br />

B. Lay out spaces and arrange suspension system in regular pattern as shown on the drawings.<br />