Section 09220<br />

Page 2<br />

A. Manufactured materials shall be delivered in the original packages, containers, and bundles bearing the name<br />

of the manufacturer and the brand.<br />

B. Plaster cement and like materials shall be stored off the ground under watertight cover until ready for use.<br />

C. Damaged or deteriorated materials shall be removed from the premises.<br />

D. Environmental Requirements: In cold weather, maintain the temperature of the building reasonably constant at<br />

not less than 55 degrees F for an adequate period prior to, during, and after the plastering operation. Provide<br />

adequate ventilation to dry plaster.<br />

E. Protection: Provide protection during plastering for finished door and window frames and other designated<br />

areas which do not receive a plaster finish.<br />

1.06 COORDINATION<br />

A. Work herein specified requires coordination with trades whose work connects with, is affected, or concealed<br />

by lathing and plastering.<br />

B. Before proceeding, make certain required inspections have been made.<br />

C. Do acutting and patching required to accommodate work of other trades.<br />

PART 2 - PRODUCTS<br />

2.01 ACCEPTABLE MANUFACTURERS<br />

A. Georgia Pacific/Bestwall<br />

B. National Gypsum Company<br />

C Thoro System Products<br />

D United States Gypsum Company<br />

2.02 MATERIALS<br />

A. Furring Channels: 16 gauge, cold rolled steel, coated with a rust inhibitive paint. In sizes as recommended by<br />

MLA and PIB.<br />

B. Tie Wire: Galvanized, annealed steel wire, 18 gauge for securing lath, 16 gauge for securing runner and<br />

furring channels in ceiling construction.<br />

C. Flat Expanded Lath: Diamond shaped mesh, cold rolled galvanized steel sheets, 3.4 lb./s.y.<br />

D. Water Barrier: DuPont Tyvek Stuco Wrap, a flash spunbonded olefin, non-woven, non-perforated weather<br />

resistant barrier.<br />

E. Accessories: shall be equivalent to USG and Keene as follows:<br />

1. Accessories shall be zinc except as noted.<br />

2. Plaster Stops - No. 66<br />

3. Bolts, Nuts, Washers - Galvanized Steel<br />

4. Control Joints - Keene No. 15.<br />

5. Corner Reinforcement - USG 1-A typical.<br />

F. Portland Cement:<br />

1. ASTM C150-95a, Type I or Type II.<br />

2. VOC emissions: Provide low VOC products in compliance with SCAQMD Rule 1113 as specified in<br />

Section 01352 IAQ Management.<br />

G. Hydrated Lime: Special finishing hydrated lime, ASTM C206-84, Type S.<br />

H. Finish System:<br />

1. Factory pre-mixed, polymer modified Portland Cement, aggregate and additives as applied over the EIFS<br />

specified in Section 07240.<br />

2. Provide low VOC products in compliance with SCAQMD Rule 1113 as specified in Section 01352 IAQ<br />

Management.<br />

I. Sand: Clean, sound, and free from loam, clay or vegetable matter, well graded from coarse to fine.<br />

J. Water: Potable<br />

K. Color:<br />

1. Integral color for coating as shown on Drawings.<br />

2. Provide low VOC products in compliance with SCAQMD Rule 1113 as specified in Section 01352 IAQ<br />

Management.<br />

L. Coating: refer to Section 09800.<br />

M. Hangers: No. 8 gage annealed, galvanized wire.<br />

N. Corner Mesh: Formed galvanized sheet steel, minimum 26 gage thick, expanded flanges shaped to permit<br />

complete embedding in plaster, minimum 2” size.<br />

NAPA CENTURY CENTER XD 12<br />

#165582

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!