Section 07920<br />

Page 2<br />

2.02 MATERIALS<br />

A. Sealants<br />

1. Type 1 – Two part, self-leveling, polyurethane sealant; FS TT-S-00227E,<br />

Class A, standard neutral color to be approved by Architect.<br />

2. Type 2 - One-part, non-sag, low-modulus, polyurethane joint sealant; FS TT-S-<br />

00227E, Class A, Type II, color as selected by the Architect.<br />

3. Type 3 – One part, neutral curing, silicone sealant; FS TT-S-00230C, FS TT-S-<br />

001543A, Class A, Use T, color to match floor.<br />

4. Type 4 – One part, non sag, neutral curing, silicone sealant, FS TT-S-001543A,<br />

FS TT-S-00230C, Class A.<br />

5. Acoustical Sealant: equivalent to USG acoustical sealant.<br />

6. Sealants within the building envelope shall comply with emission limits outlined in<br />

Section 01352 IAQ management.<br />

Firm Type 1 Type 2 Type 3 Type 4<br />

Dow Corning N/A N/A 790 791<br />

Pecora NR-200 Dynatrol 1-XL N/A 864 NST<br />

or DynaTred<br />

Sika Sikaflex-2c SL Sikaflex-15 LM N/A N/A<br />

Sonneborn SL2 NP1 N/A N/A<br />

Tremco THC-900 Spectrem 2 Spectrem 1<br />

or 901 Dymeric<br />

Sherwin Williams Stampede 2SL Stampede 1 White Lightning Silicone Ultra<br />

SW Shermax<br />

B. Caulking Compound (Interior use)<br />

1. One part acrylic latex caulk capable of being painted with latex or oil base paints; ASTM C834-95.<br />

Provide between plumbing fixtures and adjacent surfaces. Color of caulk for this application is to be<br />

white.<br />

2. Caulking within the building envelope shall comply with emission limits outlined in Section 01352<br />

IAQ management.<br />

C. Related Materials<br />

1. Primer: As required by sealant manufacturer for each type of working surface,<br />

having been tested for staining and durability on samples of actual surfaces to be<br />

sealed.<br />

2. Vertical Joint Backing: Closed-cell polyethylene joint backer rod as required by<br />

sealant manufacturer in writing to Architect. Select size that will cause an<br />

approximate 30% compression in joint.<br />

3. Horizontal Joint Backing: Round solid neoprene or butyl rubber, Shore A<br />

hardness 70.<br />

4. Expansion Joint Filler: Recompressed bitumen impregnated foam sealant; size<br />

of uncompressed material to be 3 times joint width in which to be used.<br />

5. Bond Breakers: Polyethylene tape, pressure sensitive adhesive.<br />

6. Solvents, Cleaning Agents, and other Accessory Materials: Recommended by<br />

sealant manufacturer in writing to Architect.<br />

PART 3 - EXECUTION<br />

3.01 PRECAUTIONS<br />

A. Fresh concrete shall be cured 28 days before sealants are applied.<br />

B. Application of sealants shall be performed when the substrate temperature is 40 o F and rising.<br />

C. Do sealing on the exterior before applying dampproofing.<br />