10.03.2015 Views

specs

specs

specs

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Section 07535<br />

Page 3<br />

B. Membrane system shall be one of the approved manufacturers fully adhered roofing systems using a reinforced<br />

72 mil (min.), white colored membrane, highly reflective with 20 year “overburden” warranty.<br />

2.03 MATERIALS<br />

A. Roof System Components shall be equal to the following components:<br />

1. Roofing Membrane - A prefabricated fully adhered installation meeting FM I-90 requirements, highly<br />

reflective white single-ply reinforced, 72 mils thick (minimum). Follow Manufacturer’s physical<br />

specifications and minimum performance criteria, as well as regional wind load requirements. Minimum<br />

Solar Reflective Index (SRI) value of 78, or better than.<br />

2. Membrane components: including pipe and curb flashings must be factory prefabricated from the same<br />

fabric reinforced material used for the deck membrane.<br />

3. Termination Sealant: Compatible with materials to which membrane is to be bonded, conforming to<br />

Federal Specifications TT-598 and TT-S-00230C as furnished by manufacturer.<br />

4. Distribution Plates: Factory Mutual approved stress distribution plates formed from a minimum 24<br />

gauge G-90 CQ steel with a galvalume coating, or high strength polyblend.<br />

5. Water Cut-Off Mastic: Compatible with materials with which it is used and furnished by the membrane<br />

manufacturer.<br />

6. Night Seal: Compatible with materials on which it is used.<br />

7. Pitch Pocket Sealant: A single component, self-leveling sealant furnished by membrane manufacturer.<br />

8. Fasteners: To meet FM I 90 requirements with roof deck as furnished by the membrane manufacturer<br />

9. OMITTED<br />

10. Terminations/Edge Details: Manufactured from rigid exterior vinyl with slotted holes for securement<br />

and furnished by membrane manufacturer. Other terminations/edge details must be approved and<br />

warranted by membrane manufacturer.<br />

B. Roof Deck Insulation: Roof insulation shall be R-38 value rigid polyisocyanurate insulation core bonded to<br />

glass fiber mat on both sides, approved by U.L. and roofing manufacturer, and meeting FM-I90 requirements.<br />

Submit evidence of roofing manufacturer approval to Architect prior to installation. Provide tapered insulation<br />

(identical to rigid insulation used) at counterslope, as indicated on drawings.<br />

C. Related Materials:<br />

Nailers:<br />

1. Wood Nailers shall be pressure treated for rot resistance, #2 or better lumber.<br />

2. Nailer height to match total thickness of insulation.<br />

3. Nailer shall be firmly fastened to the deck @ 16" o.c., so as to resist a force of 200 lbs. per lineal foot in<br />

any direction.<br />

D. Roof Accessories:<br />

1. Roof Hatch: Type "S-20" roof hatch, 2'-6" x 3'-0" as manufactured by Bilco Company, New Haven, CT.<br />

06505. NO SUBSTITUTIONS<br />

a. Hatch shall be complete with hinges, springs, handle, hold-open, draft seal, padlock hasp and exterior<br />

skirting.<br />

b. Provide access ladder as specified in Section 05500-Miscellaneous metals.<br />

2. Ladder Extender: Provide Ladder Up Safety post model LU-2 as manufactured by The Bilco Company.<br />

NO SUBSTITUTIONS.<br />

a. Install on fixed ladder below hatch cover in accordance with manufacturer’s instructions.<br />

3. Roof Walkways: Provide and install manufacturers approved roof walkway pads at locations shown on the<br />

drawings, and where traffic will be concentrated (i.e. access doors, roof hatches, ladders, etc.) whether<br />

shown or not.<br />

PART 3 - EXECUTION<br />

3.01 ACCEPTANCE OF SURFACES<br />

A. Installation of roofing materials shall not be started until other trades have completed the installation and<br />

testing of materials or systems which will penetrate the roof surface, requisite blocking is in place, and the<br />

surface of the respective roof deck is dry.<br />

B. Roof deck surface shall be smooth, level, and free of moisture or frost. Sharp ridges or other projections above<br />

the surface shall be removed prior to membrane application.<br />

NAPA CENTURY CENTER XD 12<br />