Section 07110<br />

Page 2<br />

PROPERTIES TEST METHOD RESULTS<br />

Tensile Strength, Film ASTM D 412 4,000 PSI minimum<br />

Tensile Strength, Membrane ASTM D 412 250 PSI minimum<br />

Elongation, Membrane ASTM D 412 300 percent minimum<br />

Moisture Vapor Permeance ASTM E 96, Method B 0.1 perms maximum<br />

Puncture Resistance, ASTM E 154 40 pounds minimum<br />

Membrane<br />

Water Absorption, ASTM D 570 0.1 maximum<br />

Membrane<br />

B. Drainage Board: Three-part prefabricated geocomposite drain consisting of a formed polystyrene core covered<br />

on one side with polypropylene filter fabric. Must be able to drain at a minimum rate of 16 gpm per foot of<br />

width covered.<br />

PART 3- EXECUTION<br />

3.01 PREPARATION<br />

A. Prepare substrate to receive waterproofing:<br />

1. Remove protrusions flush with adjacent surface.<br />

2. Remove loose and spalled concrete.<br />

3. Patch holes and depressions with patching compound.<br />

4. Clean surfaces to remove dust, loose aggregate, debris, oil, grease, and other contaminants that could<br />

impair adhesion.<br />

5. Prepare dynamic cracks and joints:<br />

a. Remove loose and spalled concrete.<br />

b. Patch holes and depressions with patching compound.<br />

c. Rout out crack or joint to minimum dimensions of ¼ inch deep x ½ inch wide.<br />

d. Apply sealant to prepared crack or joint as specified in Section 07920.<br />

3.02 INSTALLATION OF WATERROOFING<br />

A. Install waterproofing system in accordance with manufacturer’s instruction and NRCA Manual.<br />

B. Surface Conditioner:<br />

1. Apply to coverage rate required by manufacturer. Allow to dry until tack free.<br />

2. Cover only that area that will be covered with membrane in same day. Re-apply if left uncovered over<br />

24 hours.<br />

C. Membrane:<br />

1. Form ¾ inch fillet with liquid membrane on inside corners; extend minimum 6 inches in each direction<br />

at 90 mils thick.<br />

2. Cracks and joints in substrate:<br />

a. Cover static cracks with 9 inch membrane strip.<br />

b. Prior to covering joints between tilt wall panels, provide sealant over backer rod at joint and<br />

allow 48 hours to cure. Provide 1 ½” backer rod over caulked joint and apply 18” wide<br />

membrane strip centered on the joint. Truncate top of backer rod at an angle below the<br />

sidewalk.<br />

3. Cover inside and outside corners with minimum 12 inch wide membrane centered over corner.<br />

4. Apply membrane with minimum 2 ½ inch side and end laps; roll surface to eliminate wrinkles and air<br />

spaces.<br />

5. Terminate top edge of membrane at grade with metal reglet.<br />

6. Terminate bottom edge of membrane within 1 inch of bottom of wall; seal edge with trowel bead of<br />

mastic.<br />

7. Provide double membrane layer minimum 6 inches around penetrations; seal with mastic.<br />