Section 05400<br />

Page 3<br />

F. Protective Finishing: Paint abraded surfaces and welds after fabrication, using galvanizing repair paint for<br />

galvanized surfaces.<br />

PART 3 - EXECUTION<br />

3.01 INSTALLATION<br />

A. General: Install metal framing systems, steel studs and accessories in accordance with Drawings and<br />

approved shop drawings. Spacing of studs shall not exceed 16" o.c.<br />

B. Securely anchor track to floor and overhead structure or members. Seat studs squarely in the track with the<br />

stud web and flange securely attached to the flanges or web of both the upper and lower tracks.<br />

C. Allow for structural movement by providing connections designed specifically for that purpose including<br />

vertical slide clips, space between studs and top track braced with bridging in accordance with approved shop<br />

drawings.<br />

D. No splices in studs, joists, or other load carrying members shall be made without prior engineering review<br />

and specific details for any such splices. Welds shall be fillet, plug, butt or seam.<br />

E. Construct corners using minimum three studs. Double stud at wall opening, door and window jambs.<br />

F. Provide rows of horizontal bridging at spacing in accordance with approved shop drawings to resist lateral<br />

forces and stud rotation.<br />

G. Touch-up Painting: Paint abraded surfaces and welds after installation, using galvanizing repair paint for<br />

galvanized surfaces.<br />

3.02 TOLERANCES<br />

A. Maximum variation from true position: +/- 1/8" from plan location.<br />

B. Maximum variation of any member from plane: 1/8" in 10 feet.<br />

END OF SECTION<br />