Section 05200<br />

Page 2<br />

1. Member of Steel Joist Institute<br />

2. Fabrications, handling, erection and connections of steel joists shall be in accordance with latest editions<br />

of SJI Specifications.<br />

B. Welding Operator Qualifications:<br />

1. Certified within 6 months previous<br />

1.05. DELIVERY, STORAGE AND HANDLING<br />

A. Mark pieces for identification during erection.<br />

B. Deliver to site in proper sequence for erection.<br />

C. Store materials above ground; prevent corrosion, warpage and twisting.<br />

D. Do not bend or damage members during handling.<br />

E. Take precautions breaking bundles to prevent damage to materials and injury to workmen.<br />

1.06. DESIGN<br />

A. Joists shall be designed by the fabricator in accordance with the specifications of the Steel Joist Institute.<br />

B. Where loads are shown or specified, members shall be designed for the specific loading conditions required.<br />

C. Where loadings are not shown, members shall be designed for the maximum allowable load indicated in the<br />

standard load tables published by the Steel Joist Institute for the member designation and spans required.<br />

D. Fabricator shall determine and include in the work any and all special bridging or temporary bracing required<br />

for proper erection or final assembly of the work.<br />

PART 2 - PRODUCTS<br />

2.01. MATERIALS<br />

A. Steel bridging, bearing plates and wall anchors: comply with ASTM A36.<br />

B. Bolts: comply with ASTM A307.<br />

C. Welding Electrodes: comply with AWS A5.5, E70 or submerged arc Grade SAW-2.<br />

D. Steel Joists: comply with SJI Specifications.<br />

1. Provide double angle bottom chords.<br />

2. Provide extended ends where required.<br />

E. Paint: rust-inhibiting primer; comply with SJI Specifications; Paint and methods of paint application shall<br />

comply with applicable air-quality and environmental regulations.<br />

2.02. ENVIRONMENTALLY PREFERABLE PRODUCTS<br />

A. To the greatest extent possible, provide products and materials that promote stewardship of the earth's<br />

resources, promote good indoor environmental quality (IEQ), and promote efficiencies in operational<br />

performance.<br />

B. Provide products listed on the EPA Comprehensive Procurement Guidelines to the greatest extent practicable.<br />

C. Provide products listed on the USGBC Directory of Products and Services to the greatest extent possible.<br />

2.03. RECYCLED CONTENT<br />

A. Provide material with maximum amount of recycled content available that achieves performance requirements<br />

of this Section.<br />

2.04. REGIONAL MATERIALS<br />

A. Provide material with maximum amount of regional (within 500 miles) material feasible that achieves<br />

performance requirements of this Section.<br />

2.05. FABRICATION<br />

A. Design and fabricate joists in accordance with SJI Specifications.<br />

B. Accessories: Provide required sag rods, bridging, extended bottom chords and top chords, side wall anchors,<br />

wall connectors, headers, and ceiling extensions.<br />

C. Shop Paint: After fabrication, clean joists, bridging, and anchors of rust, mill scale, dirt and other foreign<br />

material. Remove grease and oil with solvents. Apply one coat of paint, minimum thickness of 2 mils.<br />

D. Extended Ends: Design to cantilever from the main span of the joist, provide load capacity at least equal to<br />

that of joist.<br />

E. Provide horizontal and X-bridging as required, minimum bridging requirements per SJI Specifications.<br />